| Product Name | 3NH TS7036 ColoriMeter | 3NH YS6080 Benchtop ColoriMeter |
| Product Price | $4237.00 | $12951.00 |
| Details | Details | |
| Model comparison | ||
| Sample type | Plane | Plane Powder Liquid |
| Measurement aperture | Φ4mm Φ8mm | Φ4mm Φ8mm Miscellaneous |
| Measurement Geometry | D/8 | D/8 D/0 |
| Color difference formula | ΔE*ab ΔE*uv ΔE*94 ΔE*00 ΔE*cmc(2:1) ΔE*cmc(1:1) | ΔE*ab ΔE*uv ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) |
| Parameter comparison | ||
| Optical inspection structure | D/8 (diffuse illumination, 8 ° direction reception) SCI/SCE measurement conforms to CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; including UV/exclude UV measurement; haze (ASTM D1003); meets CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
| integrating sphere diameter | Φ40mm | Φ154mm |
| spectroscopy | Plane grating spectroscopy | Concave grating |
| Sensor | Silicon photodiode array (dual row 32 groups) | 256 pixel dual array CMOS image sensor |
| Field of view | 2°/10° | 2°/10° |
| Illuminant | Combined Full Light spectrum LED Illuminant, UV Illuminant | 360~ 780Nm xenon arc, 400nm cut-off xenon arc, 420nm cut-off xenon arc, 460nm cut-off xenon arc |
| Illuminant life | More than 3 million measurements in 5 years | 3 years more than 500,000 measurements |
| UV Illuminant | Yes. | 360~ 780Nm xenon arc, 400nm cut-off xenon arc, 420nm cut-off xenon arc, 460nm cut-off xenon arc |
| Observational Illuminant | D65,A,C,D50,D55,D75,F1,F2(CWF),F3,F4,F5,F6,F7(DLF),F8,F9,F10(TPL5),F11(TL84),F12(TL83/U30) | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
| Wavelength range | 400~700nm | 360~780nm |
| wavelength interval | 10nm | 10nm |
| Bandwidth | 10nm | 5nm |
| Measurement caliber | Dual diameter: MAV: φ 8mm/φ 10mm, SAV: φ 4mm/φ 5mm | Reflection: φ 30mm/φ 25.4mm, φ 18mm/φ 15mm, φ 10mm/φ 8mm, φ 6mm/φ 4mm; Transmission: φ 30mm/φ 25.4mm; Switch diameter automatic identification |
| Repeatability of chromatic value | MAV/SCI, Delta E * ab within 0.05 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) | φ 25.4mm/SCI, Delta E * ab Standard Deviation within 0.012 (after instrument preheating correction, the average value of the whiteboard is measured 30 times at an interval of 5s) |
| Inter-instrument Agreement | MAV/SCI, Delta E * ab within 0.3 (BCRA series ⅱ 12 color plate measurement average) | φ 25.4mm/SCI, Delta E * ab within 0.12 (BCRA series ⅱ 12 color plate measurement average) |
| Display accuracy | 0.01 | |
| Measurement time | Approximately 1.5 seconds (approximately 3.2 seconds for simultaneous SCI/SCE testing) | About 2.4s (about 5s for simultaneous SCI/SCE testing) |
| Reflectance measurement range | L: 0~ 120 reflectance: 0~ 200% | 0~200% |
| Measurement mode | Single measurement, average measurement (2~ 99 times) | Quality Control Mode, Sample Mode |
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,βxy,DIN Lab9,DIN Lab99 Munsell(C/2) | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99 | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) |
| Whiteness/Yellowness/Blackness | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) |
| Tint/Metamerism | Metamerism index Mt | Metamerism index Mt |
| Colour fastness/force/coverage | Dip colour fastness, discoloration fastness, force, coverage | Dip colour fastness, discoloration fastness, force, coverage |
| Calibration method | ETC real-time calibrating technology, black and white correction | |
| Software support | SQCX Quality Management Software (official website download) | The PC-side software has powerful expansion functions |
| Data storage | 1000 master standards, 30,000 samples (one data can include SCI/SCE at the same time) | 5000 master standards, 40,000 samples (SCI/SCE counts as one data) |
| Interface | USB, Bluetooth ® 5.0 | USB, Bluetooth ® 4.0, print serial port |
| display screen | TFT True Color 3.5inch, Capacitive Touchscreen | TFT True Color 7inch, Capacitive Touchscreen |
| display content | Light spectrum plots/data, sample chromatic values, color difference values/plots, pass/fail results, Color simulation, Color bias | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias |
| Operating language | Simplified Chinese, English, Traditional Chinese | Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish) |
| Operating temperature | 0~40℃ | 0~40℃(32~104°F) |
| Allowable relative humidity | 0~ 85% RH (no condensation) | |
| Storage temperature | -20~50℃ | -20~50℃(-4~122°F) |
| Storage Humidity | 0~ 85% RH (no condensation) | |
| Power supply method | lithium battery | DC 24V, 3A Power Adapter |
| Dimension | L * W * H = 81 * 71 * 214mm | L * W * H = 370 * 300 * 200mm |
| Net weight | About 460g | About 9.6kg |
| Optional accessories | USB micro printer, powder test box, Bluetooth micro printer | Reflection sample holding tool, transmission holder, microporous 4mm transmission fixture, instrument inverted test fixture |
| Special features | Camera view positioning, ETC real-time calibrating, dual measurement aperture, automatic measurement easy-to-measure device | Built-in temperature sensor monitoring and compensation; Built-in camera viewfinder positioning; Independent Illuminant detector; Aperture automatic identification |