| Product Name | 3NH YS6080 Benchtop ColoriMeter | 3NH TS8210 Benchtop ColoriMeter |
| Product Price | $12951.00 | $6496.00 |
| Details | Details | |
| Model comparison | ||
| Sample type | Plane Powder Liquid | Plane |
| Measurement aperture | Φ4mm Φ8mm Miscellaneous | Φ4mm Φ8mm |
| Measurement Geometry | D/8 D/0 | D/8 |
| Color difference formula | ΔE*ab ΔE*uv ΔE*94 ΔE*cmc(2:1) ΔE*cmc(1:1) ΔEab(Hunter) | ΔE*ab ΔE*uv ΔE*94 ΔE*00 ΔE*cmc(2:1) ΔE*cmc(1:1) |
| Parameter comparison | ||
| Optical inspection structure | Reflection: D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; including UV/exclude UV measurement; transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; including UV/exclude UV measurement; haze (ASTM D1003); meets CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | D/8 (diffuse illumination, 8 ° direction reception); SCI/SCE measurement; exclude UV measurement; comply with CIE No. 15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| integrating sphere diameter | Φ154mm | Φ40mm |
| spectroscopy | Concave grating | Plane grating spectroscopy |
| Sensor | 256 pixel dual array CMOS image sensor | Silicon photodiode array (dual row 40 groups) |
| Field of view | 2°/10° | 2°/10° |
| Illuminant | 360~ 780Nm xenon arc, 400nm cut-off xenon arc, 420nm cut-off xenon arc, 460nm cut-off xenon arc | Combined Full Light spectrum LED Illuminant |
| Illuminant life | 3 years more than 500,000 measurements | More than 3 million measurements in 5 years |
| UV Illuminant | 360~ 780Nm xenon arc, 400nm cut-off xenon arc, 420nm cut-off xenon arc, 460nm cut-off xenon arc | |
| Observational Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 | D65,A,C,D50,F2(CWF),F7(DLF),F10(TPL5),F11(TL84),F12(TL83/U30) |
| Wavelength range | 360~780nm | 400~700nm |
| wavelength interval | 10nm | 10nm |
| Bandwidth | 5nm | 10nm |
| Measurement caliber | Reflection: φ 30mm/φ 25.4mm, φ 18mm/φ 15mm, φ 10mm/φ 8mm, φ 6mm/φ 4mm; Transmission: φ 30mm/φ 25.4mm; Switch diameter automatic identification | Customized single diameter: MAV: φ 8mm/φ 10mm; SAV: φ 4mm/φ 5mm |
| Repeatability of chromatic value | φ 25.4mm/SCI, Delta E * ab Standard Deviation within 0.012 (after instrument preheating correction, the average value of the whiteboard is measured 30 times at an interval of 5s) | MAV/SCI, Delta E * ab within 0.025 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) |
| Spectroscopic reflectance Repeatability | φ 25.4mm/SCI, Standard Deviation within 0.06% (400~ 700nm: within 0.05%) | |
| Inter-instrument Agreement | φ 25.4mm/SCI, Delta E * ab within 0.12 (BCRA series ⅱ 12 color plate measurement average) | MAV/SCI, Delta E * ab within 0.2 (BCRA series ⅱ 12 color plate measurement average) |
| Measurement time | About 2.4s (about 5s for simultaneous SCI/SCE testing) | Approximately 1.5 seconds (approximately 3.2 seconds for simultaneous SCI/SCE testing) |
| Reflectance measurement range | 0~200% | 0~200% |
| Measurement mode | Quality Control Mode, Sample Mode | Single measurement, average measurement (2~ 99 times) |
| Color space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 | CIE LAB,XYZ,Yxy,LCh,CIE LUV,s-RGB,βxy,Munsell(C/2) |
| Color difference formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00 |
| Whiteness/Yellowness/Blackness | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) | WI(ASTM E313,CIE/ISO,AATCC,Hunter),YI(ASTM D1925,ASTM 313) |
| Tint/Metamerism | Metamerism index Mt | |
| Colour fastness/force/coverage | Dip colour fastness, discoloration fastness, force, coverage | Dip colour fastness, discoloration fastness, force, cover 8 degrees Glossiness |
| Glossiness/shade | 8 ° Glossiness, 555 shade classification | |
| Liquid/Transmission Special | Transmission: D/0 (diffuse illumination, 0 ° direction reception) SCI/SCE measurement; includes UV/exclude UV measurement; haze (ASTM D1003) | |
| Haze/Transmittance | Haze (ASTM D1003) | |
| Software support | The PC-side software has powerful expansion functions | SQCX Quality Management Software |
| Data storage | 5000 master standards, 40,000 samples (SCI/SCE counts as one data) | 1000 master standards, 20,000 samples (one data can include SCI/SCE at the same time) |
| Interface | USB, Bluetooth ® 4.0, print serial port | USB, trigger switch interface |
| display screen | TFT True Color 7inch, Capacitive Touchscreen | TFT True Color 7.0 inch, Capacitive Touchscreen |
| display content | Light spectrum plots/data, sample chromatic values, color difference values/plots, chromaticity plots, Color simulation, pass/fail results, Color bias | Light spectrum plots/data, sample chromatic values, color difference values/plots, pass/fail results, Color simulation, Color bias |
| Operating language | Simplified Chinese, Traditional Chinese, English, (customizable German, French, Spanish) | Simplified Chinese, English, Traditional Chinese |
| Operating temperature | 0~40℃(32~104°F) | 0~40℃ |
| Storage temperature | -20~50℃(-4~122°F) | -20~50℃ |
| Power supply method | DC 24V, 3A Power Adapter | DC 24V, 3A Power Adapter |
| Dimension | L * W * H = 370 * 300 * 200mm | L * W * H = 370 * 240 * 260mm |
| Net weight | About 9.6kg | About 7.8kg |
| Optional accessories | Reflection sample holding tool, transmission holder, microporous 4mm transmission fixture, instrument inverted test fixture | Micro printer, foot switch, swirl/spin stand |
| Special features | Built-in temperature sensor monitoring and compensation; Built-in camera viewfinder positioning; Independent Illuminant detector; Aperture automatic identification | Camera view positioning, horizontal or vertical measurement, while SCI/SCE fast measurement |