Product Name HUDA QT-E702-150B70 Programmable humidity chamber kesionots KS-HW150L(150℃) Humidity Chamber
Product Price In coming $6286.00
Details Details
Model comparison
Min-TEMP -80℃ -80℃
Max-TEMP >100℃ >100℃
Min-humidity ≤20%RH ≤20%RH
Max-humidity 98% RH 98% RH
volume ≤150L ≤150L
Temp Uniformity ≤±2.0℃ ≤±1.0℃
TEMP fluctuation ±0.5℃ ±0.5℃
Humidity deviation ±2% ±2%
Humidity Uniformity ≤±3%RH
Test Types Steady State Cyclic Humidity (85/85) Low Temp Low Humidity Steady State Cyclic Humidity (85/85) Low Temp Low Humidity
Cooling Method Air-cooled Water-cooled
Parameter comparison
Interior Volume 150L 150L
Temperature Range -70℃~+150℃ -70~150℃
Temperature resolution 0.01℃ ±0.1℃
Temperature Fluctuation ≤±0.5℃ ±0.5℃
Temperature Uniformity ±2℃ ±1.0℃
Moisture control Range 20%RH~98%RH 20~98%RH
Humidity deviation ±2%RH
Temperature deviation ≤±2℃
Humidity resolution 0.1%RH ±0.1%RH
Temperature control accuracy ±0.01℃ ±1.0℃
Humidity control accuracy ±0.1%RH
Heating time Full average ≥ 3 ℃/min
cooling time Average of the whole process ≥ 1 ℃/min
Inner chamber dimensions 500*600*500mm
Dimension 1040*1500*1080mm 1000*1460*1040mm
test hole diameter 50mm
weight 266kg
Rated current 11A
rated power 7kW
power supply 220V
compressor 1 imported French Taikang fully enclosed compressor France
Refrigerant Environmentally friendly refrigerant R404
Refrigeration method Mechanical binary refrigeration
Condensation method air cooling
condenser Stainless steel brazed plate heat exchanger
evaporator finned tube heat exchanger
blower Centrifugal fan with forced circulation
Humidification system Stainless steel humidifier
Heating system Nickel chromium alloy stainless steel heater
water supply system Front-mounted water supply tank, fully automatic water supply system
controller Taiwan Youyi Controller
setting method Chinese/English interface, touch input
operation mode Program method/valuation method
setting Range Temperature Range 5 ℃
Display resolution Temperature: 0.01 ℃; Time: 0.1 min
input platinum resistance
Power-off memory function The power failure recovery mode can be set as: hot start/cold start/stop
program Volume Maximum 120 groups, 1 program can be combined by 1 to 99 segments, capacity: 1200 segments
communication interface R232/485 communication, can display Linear dispersion and data acquisition, can be used as monitoring and remote control system RS-232 standard communication interface device, can be connected with a personal computer (PC) at the same time multi-machine control and management
storage function Standard configuration 2G SD card recording test data Linear dispersion, can be uploaded and downloaded, and can expand the storage capacity
Safety protection measures Overall equipment overheating, fan overheating protection, underphase/inverse phase, refrigeration system overload, refrigeration unit overpressure, timing, leakage protection, etc
Software use environment IBM PC compatible machine, CPU above PII, memory above 128M, Simplified Chinese Windows2000/XP
Chassis shell SUS304 #stainless steel plate (1.0mm thick)
Chassis inner wall SUS304 #stainless steel plate (1.0mm thick)
thermal insulation material 100Mm polyurethane rigid foam + 100mm high density fiberglass cotton