| Measurement Range |
HLD (170-960),HS (30.6-102.6),HRC (17.9-69.5),HB (19-683),HV (80-1042),HRA(59.1-88),HRB (13.5-101.7)
|
HLD(170-960); HV(83-976); HB(30-651); HRC(17.6-68.5); HS(26.4-99.5); HRB(13.5-100); HRA(60-85.8)
|
| Applicable materials |
Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile cast iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copper, forged steel
|
|
| Indication Error |
Measurement 760 +/- 30HLD: +/- 6 HLD; measurement 530 +/- 40HLD: +/- 10 HL
|
|
| DC Type probe error |
Measurement 760 +/- 30HLDC: +/- 6 HLDC; measurement 530 +/- 40HLDC: +/- 10 HLDC
|
|
| DL Type probe error |
Measurement 878 +/- 30HLDL: +/- 12 HLDL; measurement 736 +/- 40HLDL: +/- 12 HLDL
|
|
| D + 15 Type probe error |
Measurement 766 +/- 30HLD + 15: +/- 12HLD + 15; measurement 544 +/- 40HLD + 15: +/- 12 HLD + 15
|
|
| G-probe error |
+/- 12 HLG for measurement 590 +/- 40HLG; +/- 12 HLG for measurement 500 +/- 40HLG
|
|
| C-probe error |
+/- 12 HLC for measurement 822 +/- 30HLC; +/- 12 HLC for measurement 590 +/- 40HLC
|
|
| Indication calibrated |
Adjustment with indication software
|
|
| data storage |
600 measurements (Impact 32 to 1)
|
|
| working Voltage |
3.7V lithium-ion rechargeable battery
|
|
| continuous working hours |
About 50 hours (when the backlight is not turned on)
|
|
| weight |
About 0.6kg (main engine)
|
Approximately 247 g
|
| Hardness |
7 kinds of Shaw (HS), Richter (HL), Brinell (HB), RocKwell (HRC/HRB/HRA), Victorian (HV), etc
|
|
| Miscellaneous working conditions |
The surrounding environment has no vibration, no strong magnetic field, no corrosive medium and serious dust
|
|