GB/T 5211.6-2020 "General methods of test for pigments and extenders - Part 6: Determination of pH value of an aqueous suspension" applies to the determination of pH value of aqueous suspensions of pigments and extenders. It utilizes a pH meter (accuracy ±0.02) equipped with a glass electrode and a reference electrode. The sample is weighed and mixed with deionized water, stirred with a magnetic stirrer for 1 minute, and then allowed to stand. The pH value of the suspension is measured at 23±2°C. The difference between parallel determination results should be ≤0.2. The standard specifies requirements for electrode calibration, sample preparation, and stirring time to ensure accurate pH value determination.
| Status | Active | ||
|---|---|---|---|
| CCS | G53 | ICS | 87.060.10 |
| Release Date | 2020-11-19 00:00:00 | Implementation Date | 2021-10-01 00:00:00 |