DINZAHN viscosity Cup

The DINZAHN viscosity cup determines viscosity by measuring the time it takes for fluid to completely flow out from a small hole at the bottom of the cup. It is used for on-site rapid testing of the flowability of liquids such as coatings and inks, making it suitable for production quality control.

Instruments

Measurement range 400-1800cSt, equipped with 44ml Cup volume, correction factor 0.95-1, accurate viscosity test at 25 ℃ thermostatic environment.

$ 131.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Portable design is easy to operate, volume 44ml, pore size 1.93mm, viscosity measurement range 5~ 60cst, outflow time 35~ 80s, suitable for rapid viscosity detection in the workshop.

$ 138.00

Filter diaMeter 2mm, viscosity measurement range up to 60cst, flow time 35-80 seconds, stainless steel durable and easy to clean, in line with international standards to ensure Measurement accuracy

$ 521.00

Adopting a double-sided design, the front supports No. 4 Cup and No. 2 Zahn Cup conversion, and the back supports ISO3-6, No. 3 Zahn Cup and Gardner Viscometer conversion, covering ISO2431, ASTM D4212 and other standards.

$ 256.00

Filter diaMeter 4.3mm, viscosity measurement range 200-1200cst, stainless steel corrosion resistance, in line with international standards design, can quickly assess the liquid viscosity conformity.

$ 483.00

Immersion design, 2mm outflow aperture, viscosity measurement range 5~ 60cSt, stainless steel material, ASTM D4212 standard, correction factor 0.95~ 1.05.

$ 135.00

Aperture 4.26mm, viscosity measurement range 200~ 1200cSt, stainless steel corrosion resistance, portable immersion design for easy operation, correction factor 0.95~ 1.05 to ensure accuracy.

$ 131.00

Made of stainless steel, aperture 3.76mm, Measurement range 100~ 800cSt, correction factor 0.95~ 1.05, in line with ASTM D4212 standard, suitable for Newton type liquid viscosity test.

$ 131.00

1-8Mm pore diaMeter stainless steel filter can be replaced to meet different viscosity range tests; Cup mouth annular groove design can store overflowing liquid; Cup body is made of titanium anodic oxidation aluminum material, durable and easy to clean.

$ 422.00

The 1mm-8mm pore size filter can be replaced to meet the viscosity range test of 96~ 683cSt; the annular groove of the Cup mouth is designed to store overflowing liquids, and the Cup body is easy to clean without sinkage. It is equipped with a stainless steel filter positioner.

$ 403.00

Made of stainless steel, with a flow hole diaMeter of 2.74mm and a capacity of 44ml, it can accurately measure liquids in the viscosity range of 20-250cSt at 25 +/- 0.2 ℃ Ambient Temperature.

$ 131.00

Made of stainless steel, the flow hole diaMeter is 2mm, according to DIN 53211, providing accurate viscosity measurement for Newtonian or near newtonian fluids.

$ 581.00

Made of stainless steel to ensure durability, the 2.7mm filter diaMeter is suitable for the viscosity range of 20-250cst, and the outflow time is controlled at 20-80 seconds. It is designed to meet ASTM standards to ensure measurement accuracy.

$ 478.00

Adopt replaceable filter design, support 1-8mm aperture selection; Cup annular groove can store overflowing liquid, Cup wall has no clean dead angle; comply with DIN53211 standard, with unique serial number for easy tracking.

$ 441.00

Articles

Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.
An article tells you how to choose a viscosity cup.
This article systematically introduces the uses, types, measurement principles, selection criteria, and usage methods of viscosity cups.