Equipped with needle Probe for direct insertion measurement, the range covers -50 to 300 ° C, the accuracy reaches +/- 1 ° C, Repeatability +/- 1% or +/- 1 ° C, and it is small and lightweight only 60g.
Made of tungsten, with a total length of 17-18mm and a needle diaMeter of 1mm, it has excellent wear resistance performance and accurate scratch testing ability.
Flow rate can be controlled independently for each purge needle, and the position of the air needle can be adjusted flexibly. Temperature control accuracy of +/- 0.5 ℃ (40-100 ℃), Heating time does not exceed 30 minutes, support 0-15L/min Gas flow rate adjustment.
Measurement principle of needle conductivity, Measurement range 0-80%, support a variety of material code selection, with 99 data storage and automatic statistics function, data communication can be realized through RS232 interface.
Each purge needle can independently control and adjust the Flow rate, the temperature control accuracy is +/- 0.5 ℃ @40~ 100 ℃, the position of the air needle is flexible and adjustable, and supports efficient Sampling Handling.
The diaMeter of stainless steel needle is used to puncture at a speed of 10-40mm/s, the maximum penetration force is 200KG, and the inner box is made of 304 stainless steel, which meets the standard test Environmental requirements.
Using 16-bit AD converter and K-type Thermocouple, sampling speed 16 times per second, Measurement range -50 ° C to 1300 ° C, support Fahrenheit switching and data retention functions.
Measurement principle of needle, moisture detection through the conductive rate between the stylus, Measurement range 0-80%, resolution 0.1%, support 99 data storage and LED status indication.
Using the 4-pin scribing needle specification R0.25/0.5/1.0/1 mm, by moving at a constant speed on the coating, the trajectory change from width to narrower to depth to shallower can be measured.
Adopt needle measurement technology, support 150 kinds of wood measurement, measurement range 0~ 80%, accuracy +/- (0.5% n + 0.5), with LCD digital display and LED status indication, provide USB, RS-232 and Bluetooth data interface.
12 airways can be independently controlled, air needle length 150mm adjustable position, built-in over-temperature protection device, temperature control accuracy of +/- 0.3 ℃, support simultaneous processing of multiple samples.
Suitable for low and medium Hardness material measurement, pressure needle end pressure 0.55N-8.06N, pressure needle stroke 0-2.5 mm, can be matched with test rack to reduce manual operation error, improve test accuracy and Repeatability.
With needle and inductive two measurement modes, the measurement range is 0-80% and 0-70% respectively, accuracy +/- (0.5% n + 0.5), support USB, RS-232 and Bluetooth multiple data interfaces, equipped with color coded LED real-time display moisture status.
The platinum needle element is used to achieve a wide range of measurement of +/- 1999mV, the built-in 3mol KCl gel reference solution cannot be added, and the plastic shell structure is matched with the BNC interface, which can maintain stable operation in complex environments.
With a wide temperature measurement range from -200 ° C to 1371 ° C, accuracy up to +/- 0.5 ° C, support Manual calibration and RS232 Interface, waterproof design to ensure stable operation in humid environments.