Temperature range -20~ 20 ℃, cooling capacity up to 1800W, cooling time is reduced by 35% compared with traditional equipment, open Bath can be applied to acid solution and organic solution thermostatic experiment.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.
Temperature control accuracy of +/- 2 ℃, cooling capacity up to 3240W, equipped with fully enclosed Air-Cooled Compressor and anti-corrosion circulation system, rapid temperature rise and fall, support large capacity Bath and external circulation function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with six safety protections such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature runaway alarm to ensure the stability and safety of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, and is equipped with multiple Safety protection devices including power-off protection and temperature alarm functions to ensure the stability and reliability of the experimental process.
Temperature control accuracy up to +/- 2 ℃, cooling capacity up to 10000W, equipped with 30L/min Flow rate adjustable circulating pump and anti-corrosion material system, support fast lifting and temperature multi-instrument function
Fluorine-free environmental protection design, temperature control accuracy +/- 0.5 ℃, minimum temperature -20 ℃, equipped with stainless steel heat exchanger and magnetic front gear plate, compact structure can chill down multiple devices at the same time.
Temperature range -40~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.
Temperature range -65~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming process to reduce cooling loss, circulating stirring design to ensure Temperature uniformity in the Tank.
Temperature range -30~ 95 ℃, Temperature Fluctuation +/- 0.05 ℃, dual Compressor refrigeration system to ensure rapid cooling, overall foaming Tank body to reduce cooling loss, circulating stirring design to ensure Temperature uniformity.