Liquid Temperature Measuring Instrument

The liquid temperature measuring instrument senses temperature changes by contacting the liquid with a sensor, converting physical signals into electrical signals to display numerical values. It is used to monitor the temperature of liquids in containers such as storage tanks and pipelines, ensuring process stability in the chemical and food processing industries.
Selection
When selecting, consider that the temperature measurement range covers actual needs, the accuracy matches process requirements, the probe material's corrosion resistance suits the liquid characteristics, the response speed meets monitoring frequency, and the protection rating is appropriate for the installation environment.
type
How it works
upper limit of temperature measurement
lower limit of temperature measurement
DS object distance ratio
precision

Terms

Standards

Instruments

Temperature Fluctuation +/- 0.05 ℃, Display resolution 0.1 ℃, equipped with 6 liter Tank and 8L/min Pump Flow rate, support liquid level alarm and computer communication, the inner Tank and the box are made of high quality stainless steel.

$ 1108.00

The Gamma ball volume replacement method is used to support 0.01-300 g weight range and 0.001g/cm ³ density accuracy, and the immersion depth of the liquid level can be adjusted arbitrarily and the air buoyancy error can be compensated.

$ 875.00

Adopting high temperature resistant non-alkali fiberglass insulation material, the maximum operating temperature is 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and no open flame design.

$ 143.00

Supports more than 30 chroma indicators, Measurement accuracy ≤ E * ab ≤ 0.01, single measurement only takes 1.5 seconds, minimum liquid addition is as low as 1ml, equipped with thermostatic sample tank and 7 inch Touchscreen.

$ 4075.00

Adopt high temperature resistant non-alkali fiberglass insulation material, the maximum operating temperature is 380 ℃, support internal and external dual Sensor temperature measurement, large heating area and no open flame design, can work continuously.

$ 160.00

With double-decked anodic oxidation aluminum housing structure, temperature control is achieved by chilling down and heating liquid, suitable for a variety of standard viscosity Cups, hard anodic oxidation aluminum and stainless steel materials to ensure durability.

$ 1287.00

Temperature range environment temperature to 380 ℃, can work continuously, the maximum temperature of the surface of the heating element is 380 ℃, and the sealing design of the insulating layer ensures the safety of use.

$ 114.00

Adopt electronic voltage regulation circuit without electric shock, Temperature range environment temperature to 380 ℃, can work continuously, large heating area and no open flame design, avoid bumping Glass ware.

$ 123.00

Built-in temperature sensor, no need to add reference fluid, PTFE liquid junction and 3/4NPT thread design, Cable length is 5 Meters.

$ 140.00

High-performance ceramic sand core liquid junction and silver ion trapping hydrazine structure, equipped with liquid reference system, Dimension Φ 12 × 260mm, suitable for large volume container sample detection.

$ 251.00

Using high temperature non-alkali fiberglass insulation material, the highest temperature 380 ℃, with internal and external dual Sensor temperature measurement function, large heating area and rapid heating, excellent thermal insulation effect.

$ 151.00

Adopt electromagnetic force closed-loop measurement system, Measurement range 0-400mN/m, resolution +/- 0.1mN/m, automatically read equilibrate value, support high viscosity liquid and interfacial tension test, simple operation without external computer control.

$ 3331.00

Temperature range environment temperature to 380 ℃, can work continuously. The surface temperature of the heating element is up to 380 ℃, and the insulating layer is wOven with high temperature resistant fiberglass without alkali.

$ 117.00

Cantilever structure to prevent liquid infiltration, large proportion of chilled down surface uniform heat dissipation, Speed range 60~ 2000rpm, Max. Torque 1850gcm, suitable for viscosity of 10000mPa · s liquid stirring.

$ 372.00

Temperature range environment temperature to 380 ℃, can work continuously, heating element surface temperature up to 380 ℃, insulation layer sealing resistance wire design is safe and reliable.

$ 110.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Abbe refractometer measures the relationship between refractive index and concentration of liquid coating resins.
This article introduces the method of measuring the refractive index of liquid coating resins using an Abbe refractometer and calculating the concentration based on the relationship between refractive index and concentration.
Negative pressure method leak detector for testing vacuum packaging seal integrity
The negative pressure leak detector evaluates the seal integrity of vacuum packaging by simulating a pressure differential environment. The instrument places the sample in a testing chamber and creates a vacuum to form negative pressure. If there is a leak, air or liquid will seep into the packaging, and the result is determined by observing pressure changes or the presence of bubbles.
Considerations for Channel Count and Temperature Endurance in Furnace Temperature Tracker Selection
When selecting a furnace temperature tracker, the main considerations are the number of channels and the temperature resistance duration. The number of channels is determined based on the quantity of temperature measurement points plus spare channels. Too few channels may lead to data loss, while too many channels can increase costs.
Temperature Paper Selection: Temperature Gradation and Response Speed Evaluation
This article mainly discusses how to choose the right temperature measurement paper. It points out that two key parameters should be considered during selection: the temperature steps and the response speed.
The oral dissolving film is uniformly coated by a film applicator and then dried and formed.
Oral dissolving films are prepared by a coating mechanism, where a liquid containing film-forming materials is uniformly applied onto a substrate, followed by drying to remove the solvent and form a solid film.
Abbe refractometer measures the refractive index and concentration of resin liquids.
The Abbe refractometer measures the refractive index of resin liquids using the principle of the critical angle of light, and there is a corresponding relationship between the refractive index and concentration within a certain range.
Surface Tensiometer Evaluates the Wetting and Spreading Properties of Resin Liquids
This article introduces how to use a surface tensiometer to evaluate the wetting and spreading performance of resin liquids. Wetting and spreading affect the adhesion and appearance of products such as coatings and adhesives, and the process can be described by Young's equation and the spreading coefficient.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Cobb Absorbency Tester Evaluates Paper Water Absorption Capacity
The Cobb water absorption tester is used to measure the water absorption capacity of paper or cardboard by simulating the liquid contact process and calculating the mass of water absorbed per unit area to determine the Cobb value.
Application of Paper Absorbency Tester in Sizing Process
The paper absorbency tester evaluates the absorption performance of paper by measuring the penetration of liquid on the paper. In the sizing process, sizing agents alter the hydrophilicity of the paper fiber surface, thereby affecting the paper's resistance to liquids.
Water Absorption Tester in the Detection of Tissue Paper and Paperboard
This article introduces the application of water absorption testers in the testing of tissue paper and paperboard. The instrument evaluates the water absorption performance of materials by measuring the mass or height of liquid absorbed by the sample, with common methods including the Klemn method and the capillary rise height method.