Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing function to ensure experimental stability.
The equipment adopts white water circulation system, equipped with electric sizing and aeRodynamic bubble homogenizing functions, the diaMeter of the extraction cylinder is 200mm and the capacity is 8 liters. It supports external vacuum suction, and the volume is small and easy to move.
Temperature range 37~ 65 ℃, Temperature Fluctuation +/- 0.5 ℃, using stainless steel liner and microcomputer intelligent temperature control instrument, with timing function and over-temperature water cut-off alarm, can be external circulation pump output thermostatic water flow.
Temperature control accuracy of +/- 0.5 ℃, temperature resolution of 0.1 ℃, equipped with built-in circulating water pump can output thermostatic water flow, support timing and over-temperature water cut-off alarm, to ensure the stability and safety of the experiment.
Using stainless steel liner and top cover, microcomputer intelligent temperature controller can display setting and measurement temperature at the same time, Temperature Fluctuation +/- 0.5 ℃, with timing and over-temperature water cut-off alarm function, optional built-in circulating water pump output thermostatic water flow.
Using white water circulation and electric water supply system, equipped with bubble homogenization and manual homogenization dual-use functions, the diaMeter of the extraction cylinder is 200mm, the capacity is 10 liters, and the sealing and clamping device avoids burring leakage.
Adopt stainless steel liner and microcomputer intelligent temperature control instrument, with 0.1 ℃ temperature resolution and +/- 0.5 ℃ Fluctuation, support timing and over-temperature water cut-off alarm function, optional built-in circulating water pump to achieve external circulation thermostatic output.
Using stainless steel liner and top cover, microcomputer intelligent temperature control instrument can display setting and measurement temperature at the same time, with timing and over-temperature water cut-off alarm function, temperature control accuracy of +/- 0.5 ℃, some models are equipped with built-in circulating water pump can output thermostatic water flow.
Adopt electric push Rod to drive Spreader movement, adjustable speed range of 2-200mm/s, temperature accuracy +/- 3 ℃, support Vacuum chuck and electric heating function, improve Spreader uniformity and operation convenience.
Adopt electric lifting system and frequency conversion speed regulation technology, Speed range 60~ 6900rpm, Power 1100W, equipped with dispersed impeller and sand grinding blades, can adapt to different impeller diaMeters, support chilling down water circulation temperature control.
Adopt stainless steel liner and top cover, microcomputer intelligent temperature control instrument display setting and measurement value, with timing function and over-temperature water cut-off alarm, Temperature Fluctuation +/- 0.5 ℃, volume 15L, optional built-in circulating water pump output thermostatic water flow.
The double outlet design can pRoduce UP water and RO water at the same time, the water pRoduction capacity is 10L/H, the resistivity of UP water is > 10MΩ · cm@25 ℃, and the fully enclosed pipeline design and automatic timing flushing function are adopted to ensure the stability of water quality.
Using electric pressure system and circular pressing operation mode, printing pressure 0-4mm, speed 0-100 Meters, adjustable scraper pressure and speed, support low accuracy overprinting and Color detection.
The double water outlet design can provide both UP and RO water simultaneously, with a water pRoduction capacity of 20L/H, a fully enclosed pipeline to maintain stable water quality, automatic timing flushing and water shortage protection functions, and quiet operation with noise below 40 decibels.
Using electric pressure system, the printing pressure is adjustable from 0 to 2mm, the speed range is 0 to 80 Meters, low accuracy overprinting is supported, and the computer program control operation is stable.