Using high-resolution video camera technology to replace the traditional Microscope, the temperature range is from room temperature to 350 ° C, and 4 samples can be processed simultaneously, compatible with powder and block sample measurement. Temperature resolution reaches 0.1 ° C.
Using 5MHZ Frequency and 10mm diaMeter Probe design, Measurement range 1.2-230 mm, the minimum pipe diaMeter can be measured Φ 20mm × 3mm, suitable for thickness detection in room temperature environment.
Elliptical trajectory vertical vibration design, vibration Frequency 660 times/min, maximum load 30KG, equipped with automatic cooling down system to maintain sample temperature stability, closed structure to reduce noise and pollution risk.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure stable and reliable operation.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety devices such as low water level protection and temperature runaway protection to ensure the stable operation of the equipment.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with multiple Safety protection devices including power-off protection and temperature alarm function.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway protection to ensure the stability and reliability of the experimental process.
Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, equipped with large-screen LCD display and PID automatic temperature control to ensure stable and safe operation.
Equipment Vibration Frequency 660 times/min, maximum load 30KG, elliptical trajectory movement to ensure that the sample test conditions independent equality, equipped with automatic chill down system to maintain temperature stability.
The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, Temperature Fluctuation +/- 0.05 ℃, with multiple safety functions such as low water level protection and temperature runaway alarm to ensure the stability and reliability of the experimental process.
Vibration Frequency 660 times/min, maximum load 30KG, elliptical trajectory motion to ensure that the sample test conditions are independent and equal, equipped with automatic chill down system to maintain temperature stability.
With two-way timing stirring function, Temperature range to 100 ℃, Speed range 0-2600rpm, support the maximum stirring amount of 3L, suitable for small volume sample precision and stable stirring.
Frequency of 710 vibrations per minute, mixing in 30 seconds; can handle 0.5 to 20 liters of barrel paint, equipped with safety interlock and height adjustment functions, quiet operation and easy loading.
Heat collection heating method, heating speed and energy saving, Temperature range up to 300 ℃, speed range 0-2600 rpm, support vacuum reaction and pressure reaction for a long time stirring.