Heat flux Meter

The heat flux density meter measures the rate of heat transfer per unit area through sensors and is used to detect the thermal conductivity of materials. In industries such as coatings and plastics, it monitors the heat distribution during the production process to ensure stable process parameters.
Selection
When selecting a heat flux meter, consider matching the measurement range to actual needs, ensuring sensor accuracy meets industry standards, aligning the device's response time with the detection process, and evaluating environmental compatibility and maintenance costs.

Terms

Standards

Instruments

The heat sealing paraMeters were determined by hot-pressing sealing method, the temperature control accuracy was +/- 1 ℃, the heat sealing time was adjustable 0.1-999 s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured the safety of use.

$ 1200.00

The heat sealing performance was determined by hot pressing sealing method, the temperature control accuracy was +/- 0.2 ℃, the heat sealing time was 0.1~ 999.9s, the upper and lower heat heads were independently controlled, and the double-decked heat insulation design ensured safety.

$ 1603.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, heat sealing time 0.1~ 999.9s adjustable, heat head with brass material to ensure uniform heat conduction, double-decked thermal insulation protection to ensure safe operation.

$ 3015.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, independent temperature control of upper and lower heat sealing heads, good thermal conduction effect of brass heat sealing knife, double-decked thermal insulation design to ensure safe use.

$ 1764.00

Adopt digital P.I.D. temperature control, upper and lower heat seal independent temperature control, heat sealing temperature range RT +~ 300 ℃, heat sealing pressure 0.05~ 0.7MPa, support manual and foot pedal start mode, anti-burn safety design.

$ 1413.00

Adopt digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing pressure 0~ 0.7Mpa adjustable, double cylinder structure to ensure pressure equilibrating, heat sealing knife aluminum alloy material uniform heat conduction, support automatic and manual mode.

$ 1663.00

Digital P.I.D. temperature control, temperature control accuracy +/- 1 ℃, heat sealing temperature up to 300 ℃; dual cylinder structure to ensure pressure equilibrating, heat cover temperature uniformity, support automatic and manual operation mode, improve test efficiency.

$ 1461.00

The heat sealing paraMeters are determined by hot pressing sealing method, the temperature control accuracy is +/- 0.1 ℃, the heat sealing temperature can reach 300 ℃, and the upper and lower heat sealing heads have independent temperature control and manual foot pedal dual start mode, which is safe and anti-scalding design.

$ 2110.00

The heat sealing paraMeters are tested by hot pressing sealing method, the temperature control accuracy is up to +/- 0.2 ℃, the heat sealing time is adjustable from 0.1 to 999.9s, and the upper and lower heat sealing heads are supported for independent temperature control and a variety of heat cover customization to ensure accurate and reliable test data.

$ 2494.00

Adopt double cylinder synchronous circuit and upper and lower heat seal independent temperature control, Heat seal Temperature range RT +~ 300 ℃, Temperature control accuracy +/- 1 ℃, support manual and pedal two start modes, heating head with protective cover to ensure safety.

$ 1300.00

Digital PID Temperature Control system, temperature control accuracy of +/- 0.2 ℃, the upper and lower heat head independent temperature control, double cylinder synchronous circuit to ensure pressure Balance, heat cover heating uniform, support manual and foot pedal dual operation mode.

$ 1656.00

Using transient planar heat source technology, the test time is adjustable from 5 to 160 seconds, the accuracy is +/- 3%, it supports nondestructive detection, no special sample preparation is required, and it is suitable for a variety of physical materials.

$ 5076.00

Temperature range RT +~ 300 ℃, temperature control accuracy +/- 0.2 ℃, double-decked thermal insulation design to effectively prevent burns, support manual and pedal two start mode.

$ 1361.00

Six sets of independent digital PID temperature control system to achieve +/- 1 ℃ temperature control accuracy, dual cylinder design to ensure uniform pressure at both ends, Heat Seal Temperature range RT +~ 260 ℃, support layer setting can simultaneously test five sets of different paraMeter samples.

$ 2268.00

The transient plane heat source method is used, the test time can be set for 5-160 seconds, and the test range is 0.0001-300W/(m * K). The sample is nondestructive tested, and the Probe double helix structure is combined with the exclusive mathematical model to analyze the data.

$ 6851.00

Articles

Differential Scanning Calorimetry measures the phase transition temperature of liquid crystal polymers.
This article introduces the method of determining the phase transition temperature of liquid crystal polymers using a differential scanning calorimeter. The differential scanning calorimeter analyzes the phase transition behavior of materials by comparing the heat difference between the sample and a reference material, recording the heat flow curve during temperature changes.
Differential Scanning Calorimetry for Measuring Compatibility of Plastic Blends
Differential scanning calorimetry assesses the compatibility of plastic blends by measuring the heat flow changes during heating or cooling processes.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.
Differential scanning calorimetry for determining the glass transition temperature of epoxy resin
Differential scanning calorimetry analyzes the thermal properties of materials by measuring the heat flow difference between the sample and a reference material.
The role of DSC thermal analyzer in the detection of hot melt adhesive crystallinity
The crystallinity of hot melt adhesive directly affects its properties such as bonding strength. Differential scanning calorimetry captures the thermal effect peaks corresponding to melting and crystallization by measuring the heat flow changes of the sample during heating and cooling processes.
The role of a reflection densitometer in controlling printing ink concentration.
The reflection densitometer measures the light reflectance of the ink layer and converts it into a density value, thereby objectively reflecting the thickness and concentration of the ink layer. In printing, it is used to monitor solid density, ensuring stable ink supply, replacing subjective judgment, and enabling data-driven control.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.