Support thermal deformation and Vicat softening point test, Temperature range up to 300 ℃, Temperature control accuracy +/- 0.5 ℃, mechanical mixing and large capacity Tank to ensure uniform insulation field, double control mode operation flexibility.
Temperature range RT +~ 300 ℃, heating rate 120 ℃/h or 50 ℃/h, maximum deformation Measurement range 1mm, support thermal deformation and Vicat test, real-time display and alarm function.
Temperature range RT +~ 300 ℃, heating rate 120 +/- 10 ℃/h, with sample rack lifting function, automatic stop heating at the end of the test, printable report Linear dispersion, suitable for Non-metallic material testing.
Automatically detect the drop point and softening point of amorphous polymer compounds, temperature resolution 0.1 ℃, heating rate adjustable eight gears, in line with ASTMD3461-97 standard, easy to operate and strong sense of cleanliness.
The Benchtop structure supports three-station testing, and the control accuracy of the constant rate heating algorithm reaches +/- 0.5 ° C. The data can be automatically recorded and exported to Excel. Transformer oil or methyl silicone oil is used as the heat conduction medium to ensure uniform heat preservation field.
It adopts copper ring and steel ball structure, supports 2-3.55 gram steel ball configuration, and accurately determines the softening temperature of the material through the drop distance of 25.4 mm, which is suitable for all kinds of asphalt experiment needs.
Dual channel simultaneous detection, Temperature range RT +~ 360 ℃, high-resolution video real-time observation and recording of the whole process, support 0.1 ℃/min -20 ℃/min continuous heating rate, easy to verify the results.
Adopt high definition camera to observe the measurement process in real time, dual-channel simultaneous detection, adjustable heating rate 0.1-20 ℃/min, support video playback and automatic interpretation of deformation characteristics.
Single point temperature measurement design, temperature point 70 ℃, irreversible discoloration characteristics, anti-fouling protective film design, specification 2.5x4 cm, service life indoor 3 years.
Measuring temperature, Humidity and dew point at the same time, dewpoint temperature range -40~ 40 ℃, with automatic memory function, digital LCD display ignore the difference, Sampling time is only 0.4 seconds, the structure is sturdy and portable.
Built-in Probe design, surface temperature Measurement range -40~ 80 ℃, air temperature accuracy +/- 0.5 ℃, Humidity range 0~ 100% RH, providing stable and reliable dew point monitoring.
Using PID system control and High Accuracy temperature sensor, Temperature range RT +~ 350 ℃, melting point Test accuracy is the highest +/- 0.5 ℃, heating rate 3.0 ℃ -5 ℃/min, to ensure stable and efficient testing.
Measurement accuracy of 1% F. S and 1 × 10~ 0.1M wide range, support 5 point calibrating, automatic temperature compensation and 500 data storage, built-in clock conforms to GLP specifications.
Measurement accuracy of +/- 1% F. S with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation to ensure measurement Stability and accuracy.
Adjustment with 5 point buttons, 8 Ion concentration calibrated point selection, Measurement accuracy of +/- 1% FS, automatic temperature compensation to ensure full scale accurate measurement, 500 data storage and GLP compliance.