$ 696.00Ex works
Measurement accuracy of +/- 1% F. S with 5 point button calibrating and automatic end point locking, 500 data storage and automatic temperature compensation to ensure measurement Stability and accuracy.
Category : Ion Meter
Brand : Bante
SKU : NB014783
Service :The delivery and service By NBCLab.Com
The Bante931-Ca calcium ion meter is a laboratory ion meter from the BANTE brand, dedicated to the measurement of calcium Ion concentration in liquid samples. Measurement accuracy of 1% F. S, support for 5 point button calibrating and automatic endpoint locking for accurate calcium Ion concentration analysis.
1. Precision calcium ion meter with large screen backlit LCD. 2.2 to 5 point button calibrated, optional 8 Ion concentration calibrated points. 3. Read the Ion concentration value directly to avoid cumbersome conversion and calculation. 4. Optional concentration units (ppm, mg/L, mol/L) to meet a variety of ion measurement needs. 5. Automatic temperature compensation to ensure accurate measurement within the full range. 6. Automatic calibration reminder, prompts the user to calibrate the meter regularly. 7. Automatic end point lock, keep stable Measured value for easy browsing or recording. 8. mV Measurement mode for calculating Electrode range to ensure measurement accuracy. 9. The system menu can customize the number of calibrated points, Ion concentration unit, Stability standard, data lock mode, automatic shutdown mode and other 8 functional parameters. 10. One-click reset function, automatically restore the meter to the factory default settings. 11. Extended memory can store up to 500 sets of measurement data. 12. The built-in clock automatically marks the date and time of stored data to comply with GLP specifications. 13. USB Communication interface sends stored data to PC.
The Bante931-Ca calcium ion meter uses ion-selective Electrode measurement of calcium Ion concentration in liquid samples, combined with automatic temperature compensation and Adjustment, to ensure measurement accuracy. The instrument calculates Electrode range in mV Measurement mode and optimizes performance by customizing parameters through the system menu.
Laboratory measurement of calcium Ion concentration in liquid samples
GLP specification
1. Connect Calcium Ion Selective Electrode and Temperature Probe. 2. Turn on the meter and select Ion Measurement mode. 3. Perform 2 to 5 point key calibration. 4. Electrode is immersed in the sample and wait for the Measured value to stabilize. 5. Read or lock the Ion concentration value. 6. Use the USB interface to transfer data to the computer.
• Measurement accuracy is regularly calibrated. • Check that Electrodes and Accessories are in good condition before use. • Avoid operating in extreme temperature environments. • Ensure that the built-in clock is accurate when storing data. • Follow automatic shutdown settings to save power.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.