Hot Melt Adhesive High Temperature ViscoMeter

The hot melt adhesive high-temperature viscometer measures the flow resistance of a sample by heating it to a molten state. It is used to monitor changes in the viscosity of adhesives at processing temperatures, guiding adjustments in production formulations and quality control.
Selection
When selecting, consider the temperature range covering the material's melting point, the corrosion resistance of the rotor material, the data acquisition accuracy meeting process requirements, the operation interface aligning with personnel usage habits, and maintenance costs matching the equipment's lifespan to the actual budget.

Terms

Standards

Instruments

Equipped with 8 Meters Oven, roller heating temperature up to 200 ℃, effective application width 500mm, Spreader thickness range 0.005-3mm, support automatic unwinding to winding process, suitable for hot-melt adhesive film.

$ 29120.00

Can measure 50~ 200000mPa · s viscosity range, Temperature control accuracy of +/- 0.1 ℃, the use of high subdivision stepper motor to ensure smooth Rotation speed, support the whole process of monitoring viscosity - Linear dispersion, beyond the range of automatic alarm.

$ 1645.00

The equipment adopts High Accuracy modular Spreader station, all-electric control without air source, minimum glue thickness 0.01mm, Spreader speed 2-4.5 m/min adjustable, with electronic control precision tension to adapt to a variety of materials such as paper, plastic and metal film.

$ 5721.00

The thickness range of Spreader is 0.01mm~ 2mm, the minimum gluing thickness is 0.01mm, the coating surface density ≤ +/- 1.5%, the dial Meter is used to fine-tune the gap and the Teflon baffle to adjust the width, and it supports forward and reverse continuously variable speed and automatic winding.

$ 4269.00

High Accuracy modular Spreader station structure, Spreader thickness range of 0.01mm to 2mm, coating speed 2-4.5 m/min adjustable, support forward and reverse stepless variable speed and automatic winding, gap adjustment Graduation up to 0.001mm, easy to accurately control the Spreader process.

$ 5399.00

Coating speed 1~ 10m/min adjustable, Spreader thickness range of 0.005-3mm, drying temperature up to 200 ℃, equipped with infrared drying and air cooling system to achieve efficient Spreader and drying.

$ 51711.00

Adopting MCU to adjust power and temperature control mode, temperature control accuracy +/- 0.5 ℃, with eight standard test force, can meet the needs of different material testing, suitable for melt flow performance measurement at high temperature.

$ 945.00

Temperature control accuracy of +/- 0.5 ℃, equipped with eight standard test force, can accurately determine the melt flow performance of polymers at high temperatures, to meet a variety of material testing needs.

$ 977.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 10~ 1000000mPa · s, temperature accuracy +/- 0.1 ℃, support continuously variable speed and direct liquid crystal display, no need for secondary calculation.

$ 1886.00

Maximum Spreader width up to 1000mm, Spreader speed 1-10m/min adjustable, support unlimited length Spreader and automatic winding, forward and reverse stepless speed change, discharge and receiving reel tension adjustable, heating Rod and glue slot can be quickly disassembled to clean up residual glue.

$ 29120.00

Can measure the dynamic viscosity of normal temperature solid high temperature molten fluid, viscosity range 10~ 200000mPa · s, Temperature range RT +~ 250 ℃, repRoducibility +/- 0.5% F. S, support a variety of Rotor speed and timing functions.

$ 1476.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 5~ 1000000mPa · s, Temperature control accuracy of +/- 0.1 ℃, support real-time display of shear rate and shear stress, out of range automatic alarm.

$ 2313.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range of 50~ 10000000mPa · s, temperature control accuracy +/- 0.1 ℃, support real-time monitoring of viscosity-temperature Linear dispersion and over-limit alarm function.

$ 2475.00

Equipped with a universal joint device to make the page even and avoid tearing; the upper limit setting function of the force value can automatically return to protect the page when the set value is reached; Measurement range 0-300N, accuracy +/- 1%; support 5-120mm/min speed adjustable.

$ 3507.00

Rotation speed is accurate and stable with high subdivision stepper motor, viscosity range 400~ 80000000mPa · s, temperature accuracy +/- 0.1 ℃, support the whole process of monitoring viscosity-temperature Linear dispersion, suitable for solid to liquid substance measurement.

$ 2688.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Hot air aging oven measures the long-term thermal-oxygen life of engineering plastics.
This article introduces how to use a hot air aging oven to test the long-term thermal-oxidative lifespan of engineering plastics. The test is based on the Arrhenius equation, which accelerates material aging at high temperatures to simulate performance changes under actual usage conditions.