Using forced warm air circulation to ensure uniform temperature, Temperature resolution of 0.1 ℃, equipped with microcomputer LCD controller temperature control is accurate, mirror stainless steel liner is easy to clean, the door opens automatically stop heating.
Forced circulation convection air duct to ensure uniform temperature, Temperature range Rt + 10~ 200 ℃, Temperature Fluctuation +/- 1 ℃, with over-temperature alarm and up to 9999 minutes timing function, suitable for a variety of non-flammable and explosive materials processing.
Equipped with forced hot air circulation system to ensure uniform temperature distribution, temperature control accuracy of +/- 0.3 ℃, support 0-999 hours timing and nine-point fault warning function, using PID automatic calculation to reduce manual setting inconvenience.
Temperature uniformity is ensured by forced circulation convection air duct, temperature control accuracy of 0.1 ℃, with Sensor fault alarm and over-temperature protection function, Timer Range can be selected from 0-9999 minutes or hours, suitable for a variety of non-flammable and explosive materials processing.
Temperature range foster RT + 5~ 80 ℃, drying 80~ 220 ℃, Temperature Fluctuation +/- 0.5 ℃, mirror stainless steel liner is easy to clean.
Temperature uniformity is improved by fan speed control, air duct circulation system automatically discharges water vapor, temperature control accuracy of +/- 0.5 ℃, equipped with independent temperature limit alarm and RS485 interface expansion function.
Inner Chamber dimensions 500 * 600 * 750mm, Volume 225L, Temperature Fluctuation +/- 0.5 ℃, using air duct circulation system to automatically discharge water vapor, improve Temperature uniformity, support RS485 interface connection recorder.
Adopt air duct circulation system to automatically discharge water vapor, Temperature Fluctuation +/- 0.5 ℃, large screen LCD display multiple sets of data, independent temperature limit alarm system to ensure safe operation.
Adopt double circulation air duct system and stainless steel heating pipe, Temperature control accuracy up to +/- 1 ℃, Temperature resolution 0.1 ℃. Studio shelf adjustable, insulation layer thickness over 70mm, effectively reduce heat loss and improve Temperature uniformity.
Vertical double air duct vertical hot air circulation design, temperature uniformity +/- 1.0 ℃, variable speed fan can adjust the air volume, large screen LCD display, independent temperature limit alarm system to ensure safe operation.
Temperature range foster RT + 5~ 80 ℃, drying 80~ 250 ℃, Temperature Fluctuation +/- 0.5 ℃ to +/- 1 ℃, forced warm air circulation to ensure uniform temperature, mirror stainless steel liner easy to clean.
Adopt hot air circulation system to ensure Temperature uniformity, Temperature Fluctuation +/- 1 ℃, volume 30L, with over temperature deviation protection and timing function, can adjust the air inlet and exhaust volume.
Vertical double air duct vertical hot air circulation design to ensure uniform temperature distribution, speed control fan can adjust the air volume according to experimental needs, Inner Chamber dimensions 350 × 350 × 350mm, volume 42L, with independent temperature limit alarm system and paraMeter memory function.
Vertical double air duct vertical hot air circulation to ensure temperature uniformity, speed control fan can adjust the air volume to avoid blowing powder items, Temperature range RT + 10-300 ℃, studio volume 225L, equipped with independent temperature limit alarm system to ensure experimental safety.
Adopt vertical double air duct vertical hot air circulation, Temperature Fluctuation +/- 1.0 ℃, Inner Chamber dimensions 350 × 350 × 350mm, equipped with PID microcomputer intelligent temperature control instrument and adjustable speed fan to ensure uniform and stable temperature.