Desktop ZAHN Viscosity Cup

The desktop ZAHN viscosity cup calculates viscosity by measuring the time it takes for a specific volume of fluid to flow out through a small hole at the bottom of the cup. It is used for quality control of liquids such as coatings and inks, and its simple operation makes it suitable for rapid on-site testing.
Selection
Select the corresponding cup model based on the viscosity range of the material being tested, taking into account temperature stability and material compatibility. Regularly calibrate with standard fluids, and ensure the cup rim is intact and the channels are clean.

Terms

Standards

Instruments

Measurement range 400-1800cSt, equipped with 44ml Cup volume, correction factor 0.95-1, accurate viscosity test at 25 ℃ thermostatic environment.

$ 131.00

Portable design is easy to operate, volume 44ml, pore size 1.93mm, viscosity measurement range 5~ 60cst, outflow time 35~ 80s, suitable for rapid viscosity detection in the workshop.

$ 138.00

Filter diaMeter 2mm, viscosity measurement range up to 60cst, flow time 35-80 seconds, stainless steel durable and easy to clean, in line with international standards to ensure Measurement accuracy

$ 521.00

Filter diaMeter 4.3mm, viscosity measurement range 200-1200cst, stainless steel corrosion resistance, in line with international standards design, can quickly assess the liquid viscosity conformity.

$ 483.00

Immersion design, 2mm outflow aperture, viscosity measurement range 5~ 60cSt, stainless steel material, ASTM D4212 standard, correction factor 0.95~ 1.05.

$ 135.00

Aperture 4.26mm, viscosity measurement range 200~ 1200cSt, stainless steel corrosion resistance, portable immersion design for easy operation, correction factor 0.95~ 1.05 to ensure accuracy.

$ 131.00

Made of stainless steel, aperture 3.76mm, Measurement range 100~ 800cSt, correction factor 0.95~ 1.05, in line with ASTM D4212 standard, suitable for Newton type liquid viscosity test.

$ 131.00

Made of stainless steel, with a flow hole diaMeter of 2.74mm and a capacity of 44ml, it can accurately measure liquids in the viscosity range of 20-250cSt at 25 +/- 0.2 ℃ Ambient Temperature.

$ 131.00

Adopting a double-sided design, the front supports No. 4 Cup and No. 2 Zahn Cup conversion, and the back supports ISO3-6, No. 3 Zahn Cup and Gardner Viscometer conversion, covering ISO2431, ASTM D4212 and other standards.

$ 256.00

Made of stainless steel to ensure durability, the 2.7mm filter diaMeter is suitable for the viscosity range of 20-250cst, and the outflow time is controlled at 20-80 seconds. It is designed to meet ASTM standards to ensure measurement accuracy.

$ 478.00

Using stainless steel material, filter diaMeter 3.8mm, viscosity measurement range 100-800cst, outflow time 20-80 seconds, suitable for medium viscosity fluid rapid test.

$ 478.00

Made of stainless steel, filter diaMeter 5.3mm, viscosity measurement range 400-1800cst, can test high viscosity liquid, flow time 20-80 seconds, in line with international standards.

$ 485.00

Flow hole diaMeter 6mm, Cup height 74mm, stainless steel material, in line with international standards, suitable for Newtonian or near newtonian fluid, providing accurate viscosity assessment.

$ 587.00

Outflow aperture 3.4mm, viscosity measurement range 49~ 220cSt, aluminum alloy Cup with stainless steel aperture, in line with ASTM D1200 standard, suitable for laboratory viscosity testing.

$ 167.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Articles

The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
Flash Point Tester Selection: Applicable Scenarios for Closed Cup and Open Cup Methods
This article introduces the differences between the closed-cup method and the open-cup method in flash point testing.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Key steps for measuring the efflux time of varnish using a viscosity cup method
This article introduces the method for measuring the outflow time of varnish using a viscosity cup. The principle is based on Poiseuille's law, where viscosity is estimated by recording the time it takes for the liquid to completely flow out from the small hole at the bottom of the cup—longer times typically indicate higher viscosity.
Standard Method for Measuring the Melt Viscosity of Hot Melt Adhesives with a Rotational Viscometer
This article introduces the standard method for measuring the molten viscosity of hot-melt adhesives using a rotational viscometer. During the measurement, the hot-melt adhesive sample must be fully melted and degassed, placed into a measuring cup, and then measured with the rotational viscometer at a set temperature.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
Rotational Viscometer Method and Viscosity Cup Method for Determining Ink Viscosity
This article introduces the principles and operations of measuring ink viscosity using the rotational viscometer method and the viscosity cup method.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Density Determination: Selection Strategy between Pycnometer Method and Densimeter Method
This article introduces two methods for measuring the density of substances: the pycnometer method and the densimeter method. The pycnometer method calculates density by measuring the mass of a sample of fixed volume. It is suitable for measuring liquids, powders, and small granular solids, offering high precision but slower operation, and requires temperature control.
How to Choose Between the Ring and Ball Method and the Cup and Ball Method for Softening Point Testers? Read This and Stop Worrying
This article introduces two main methods for determining the softening point of materials: the ring-and-ball method and the cup-and-ball method. The ring-and-ball method is more widely used and is suitable for materials such as asphalt. It involves measuring the temperature at which a steel ball causes the sample to sink. The cup-and-ball method is often used for specific resins or wax products, relying on the flow of the sample or the penetration of a steel ball to determine the endpoint.
Types and Selection of Paint Viscosity Cups
As a simple tool for measuring the liquid outflow time, the viscosity cup is mainly categorized into various types such as the Tu-4 cup, ISO cup, Ford cup, and Zahn cup, based on standards from different countries and regions. These cups differ in orifice size, capacity, and the types of fluids they are suitable for.