Seamless Steel Tube Thickness Gauge

The seamless steel pipe thickness gauge emits sound waves into the pipe wall through an ultrasonic probe, receives the reflected signals to calculate the propagation time, and converts it into thickness based on the speed of sound. It is used to detect the uniformity of steel pipe wall thickness, preventing substandard wall thickness during pipeline manufacturing, installation, and maintenance.
Selection
When selecting, consider the material of the steel pipe and the matching of curvature with the probe frequency. High-temperature environments require high-temperature-resistant models. The measurement range should cover the expected thickness, and the accuracy must meet the process requirements. Portable models are suitable for on-site inspection, while fixed models are suitable for continuous measurement on production lines.

Terms

Standards

Instruments

Standard light sources including D65 and UV, seamless construction to ensure no light leakage, special steel plate base for enhanced durability, no preheating and low energy consumption, support for Illuminant use time display and automatic switching function.

$ 428.00

With six types of Illuminants including D65 and UV, the seamless structure ensures no light leakage, the special steel plate base is more durable, no preheating is required, and the energy consumption is low. It supports Illuminant use time recording.

$ 493.00

Using 90 ° Measurement Angles and eddy Current principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures stable and reliable measurement on complex geometries.

$ 235.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Using 90 ° Measurement Angles and magnetic Induction principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures measurement accuracy and Stability.

$ 167.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Range 20-370 microns, accuracy 10 microns, stainless steel corrosion resistance, hexagonal design with 24 scales, suitable for different Coating thickness measurement.

$ 231.00

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

Measurement range of 5-500μm with a three-blade design, LED Illumination Microscope and swirl/spin system for accurate assessment of Coating thickness and substrate defects.

$ 296.00

Measurement range 0-12mm, Accuracy of 1-3%, Support automatic identification of matrix material and continuous Measurement mode, suitable for pipeline anticorrosive layer defect location.

$ 696.00

Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.

$ 119.00

Using 0.08mm ultra-fine wire seamless winding process, wet film thickness control accuracy of 6.9μm, application width 300mm, suitable for a variety of fluid materials uniform Spreader.

$ 160.00

Made of precision stainless steel, with a range of 50 to 950 μm, the 10-step tooth design can accurately measure wet film thickness, ensure painting mass and avoid material waste.

$ 109.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.