The kinematic viscometer calculates viscosity by measuring the time it takes for a fluid to flow through a capillary tube under gravity. It is used to detect the flow characteristics of fluids such as coatings and inks, and finds applications in quality control and process adjustments.
Selection
When selecting a kinematic viscometer, it is necessary to consider the viscosity range of the fluid being measured and match it with an appropriate capillary inner diameter. The measurement cell volume should be chosen based on the sample quantity. The influence of ambient temperature requires the inclusion of a temperature control system. Additionally, the ease of operation and data output methods should meet the requirements of daily testing.

Terms

Standards

Instruments

Controlled by single chip microcomputer, temperature accuracy +/- 0.03 ℃, kinematic viscosity measurement range 0.5~ 20000mm ²/s, automatic tracking of heating Linear dispersion and precise control of water Bath and oil Bath temperature.

$ 2116.00

Adapt to a variety of Viscometer use, suitable for factory field applications, real-time printing measurement results, no need to hand copy, easy operation, can save labor time.

$ 183.00

The test program can be uploaded to the Viscometer host, the analysis record data can be collected, the rheological Linear dispersion and Excel can be generated, and five sets of data can be plotted and compared at the same time.

$ 204.00

Measurement accuracy of 0.1 ℃, range of 0~ 100 ℃, real-time display of temperature values, suitable for a variety of Viscometer models, to ensure a stable test environment.

$ 135.00

With 200-320000000mPa · s wide range and +/- 1% Measurement accuracy, support PT100 temperature detection and 10 sets of program storage functions, can automatically calculate Rotor speed combined range.

$ 5850.00

Silicone oil standard solution, calibrated viscosity 380cp, capacity 400ml, suitable for Viscometer calibrating.

$ 185.00

Measurement range 100-13000000cP, Repeatability +/- 0.2% F.S., supports 10 program stores and TTT/TTS Measurement mode, can automatically calculate the range and export Excel data.

$ 4721.00

Using 10L Glass Bathtub, small size and less medium consumption, temperature control accuracy of +/- 0.05 ℃, automatic accurate timing and viscosity calculation, support 4 holes at the same time experiment, easy and reliable operation.

$ 1910.00

Measurement accuracy +/- 2%, equipped with 5 calibrated oils to ensure measurement accuracy, as a special accessory for cone-plate viscoMeter to achieve stability testing.

$ 2953.00

The shear rate is 2.0N, only 0.5ml sample volume can be completed to complete the test, suitable for a variety of models of Viscometer host, to meet the measurement needs of different viscosity ranges.

$ 683.00

Provides accurate viscosity values of 5.7cp, 400ml per bottle for Viscometer calibrated measurement Stability and Reliability.

$ 185.00

Measurement range 200-106000000mPa · s, accuracy +/- 1% F. S, support 18-speed Rotation speed control and PT100 temperature sensor, with Self-check function and 10 sets of program storage, can generate Excel data reports.

$ 4721.00

With 998 stepless Rotation speeds and 30 sets of program storage, Measurement accuracy of +/- 1% F. S, real-time display of viscosity Linear dispersion and support for shear rate range settings.

$ 1798.00

U-tube countercurrent design, viscosity measurement range 0.6-3 cSt, accurate determination of liquid kinematic viscosity based on capillary tubing principle, suitable for a variety of liquid samples.

$ 461.00

Equipped with 7-inch Touchscreen for easy operation, anti-static shell design is safe and reliable, viscosity measurement range 1~ 1500000mPa · s, support automatic conversion of power and kinematic viscosity, built-in temperature Probe to ensure accurate data.

$ 2232.00

Articles

How to choose the right rotational viscometer?
This article introduces how to select an appropriate rotational viscometer, so you won't be blind when choosing a viscosity measurement instrument!
Stormer viscometer controls the in-can viscosity of latex paint.
This paper introduces the application of the Stormer viscometer in controlling the paint can viscosity of latex paint. Paint can viscosity affects application performance and user experience, with either too high or too low values causing issues.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Rotational Viscometer Measures Viscosity and Processability of Resin Melts
A rotational viscometer calculates viscosity by measuring the torque experienced by a rotor as it rotates in the resin melt, thereby helping to understand the material's processing properties.
Rotational Viscometer for Measuring and Controlling the Application Viscosity of Coatings
A rotational viscometer is a commonly used tool for controlling the viscosity of coatings during application, as it measures the torque generated by a rotor rotating in a fluid to calculate viscosity.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Stormer Viscometer for Determining Krebs Viscosity of Paints
This article introduces the method of measuring the Krebs viscosity value of colored paints using a Stormer viscometer. Viscosity is a key indicator that affects the application and storage of coatings. The Krebs unit (KU) quantifies viscosity based on the resistance encountered by a rotor as it rotates within the paint sample.