Pure oil-free design ensures clean gas, exhaust volume of 1500L/min, automatic start and stop to reduce energy consumption, pressure dew point 2-10 ℃, suitable for a variety of industry needs.
Adopt pure oil-free design to ensure clean gas, dew point range -40~ -60 ℃, exhaust volume 600L/min, automatic start and stop to reduce energy consumption, no need for special personnel on duty and easy maintenance.
The bottom hole and tip design are adopted, and the outflow time is determined by observing the appearance of the tip, which realizes rapid viscosity measurement and is suitable for on-site testing needs.
The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 10 ° C/min, and the PID adaptive algorithm is equipped to ensure the Temperature Fluctuation +/- 0.5 ° C. The temperature uniformity is guaranteed by the design of the top orifice air supply.
Adopt multi-channel mechanical compression refrigeration system and adaptive throttling technology to achieve rapid temperature change of 5 ° C/min; Equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure temperature uniformity.
The multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, and the PID adaptive algorithm is equipped to ensure that the Temperature Uniformity is ≤ 2 ° C, and the 512L studio meets the diverse testing requirements.
Adopt multi-channel mechanical compression refrigeration system and frequency conversion technology to achieve rapid temperature change of 5 ° C/min; equipped with PID adaptive algorithm to ensure Temperature Uniformity ≤ 2 ° C, support 120 groups of program editing and remote monitoring functions.
Measurement range 0-99.9%, resolution 0.1%, Response Time 1 second, portable design supports rapid on-site detection, probe Sensor can penetrate deep into the material internal measurement.
With a linear temperature rise and fall rate of 10 ° C/min and a wide temperature range of -60 to 150 ° C, multi-channel refrigeration system and PID adaptive algorithm are used to achieve rapid temperature convergence, and environmentally friendly refrigerants and low noise design are equipped.
Conductivity Detector principle and temperature and humidity compensation technology, measurement accuracy of +/- 0.5%, Response Time of 1 second, integrated design supports on-site rapid detection, suitable for a variety of grain moisture measurement.
Multi-channel mechanical compression refrigeration system and adaptive throttling technology are used to achieve 5 ° C/min linear temperature rise and drop and +/- 0.5 ° C Temperature Fluctuation; equipped with PID adaptive algorithm and forced air duct system to ensure temperature uniformity and rapid convergence.
Multi-channel mechanical compression refrigeration system is used to achieve rapid temperature change of 15 ° C/min, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through forced air duct system to ensure Temperature Uniformity ≤ 2 ° C, with remote monitoring function.
Far infrared radiation heating technology, Temperature range RT +~ 300 ℃, Temperature Fluctuation +/- 2 ℃, equipped with thermistor control thermoMeter, rapid low consumption drying, suitable for a variety of Sample Handling.
Adopting the principle of high-frequency electromagnetic wave induction, scanning depth 50mm, Response Time 1 second, support multi-gear measurement and plug-in rapid detection, small size for on-site use.
Adopt multi-channel adaptive refrigeration system to achieve 10 ° C/min rapid temperature change, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through the top orifice plate uniform air supply to ensure temperature uniformity, support 120 groups of program editing and remote monitoring functions.