$ 13064.00Ex works
Adopt multi-channel adaptive refrigeration system to achieve 10 ° C/min rapid temperature change, equipped with PID adaptive algorithm to ensure Temperature Fluctuation +/- 0.5 ° C, through the top orifice plate uniform air supply to ensure temperature uniformity, support 120 groups of program editing and remote monitoring functions.
Category : High Low Temperature Test Chamber
Brand : HUDA
SKU : NB041420
Service :The delivery and service By NBCLab.Com
HUDA QD-E708-150K40-X10 rapid temperature change test chamber is used to determine the adaptability of electronic products, automotive parts, materials, etc. under the conditions of high humidity, low humidity, constant heat and humidity, high and low temperature rapid alternating cycle, surface condensation heat and humidity. The testing machine adopts reasonable structure and stable and reliable Control mode, has the characteristics of beautiful appearance, easy operation, safety, high temperature and humidity control accuracy, and is a professional equipment for rapid temperature change test, constant temperature and humidity test, alternating humidity cabinet test.
1. Adopt multi-channel, environmentally friendly and energy-saving (low noise) mechanical compression refrigeration system, use environmentally friendly materials and two-stage multi-channel main bypass system, combined with frequency conversion technology to achieve energy saving, low noise and high control accuracy. 2. The self-developed multi-channel and multi-stage throttling system automatically adjusts the capillary tubing throttling through the intelligent control system to ensure uniform temperature changes and small fluctuations. 3, the application of broadband compression equilibrating temperature control system, the use of fast convergence PID adaptive algorithm, to achieve rapid temperature control and uniformity. 4. Realize remote visual control, configure human-machine management interface and RS485 communication, support graphical interface, automatic fault prompt, and remote monitoring.
Through the built-in air chamber, circulating air duct and stainless steel circulating fan, the adjusted temperature and humidity in the mixing chamber are evenly blown out from the top to the test space to achieve uniform control of temperature and humidity. The refrigeration system adopts multi-channel, multi-stage throttling and mechanical compression refrigeration, combined with PID adaptive algorithm, automatically adjusts the refrigeration output and temperature change rate to ensure fast convergence and Stability.
Electronics, automotive parts, materials
GB2423.1-2008/IEC6008-2-1-2007、GB/T 2423.2-2008、GJB150.3A-2009、GJB150.4A-2009、GB2423.22-2008、GBT 2424.5-2006、GB/T 10589-2008、GB/T2423.3-2008(IEC68-2-3)、GJB150.9A-2009、G/BT 2423.4-2008/IEC6008-2-30:2005、GB/T5170.18-2005、GB/T10586-2006、GBT 2424.6-2006、GBT 2424.7-2006
1. Ensure that the ground of the installation site is flat, well ventilated, free of flammable and explosive corrosive gases, and leave appropriate maintenance space. 2. Connect the power supply and check whether the voltage and frequency meet the requirements (AC380V three-phase four-wire system, voltage fluctuation range of 10%, frequency 50 +/- 0.5Hz). 3. Set the temperature and humidity parameters through the control panel, and you can choose the program mode or the fixed value mode to operate. 4. Start the equipment, monitor the actual temperature and humidity and program execution status, and remotely monitor if necessary. 5. After the test is completed, turn off the device and disconnect the power supply.
• The installation site needs to be flat, well ventilated, free of flammable and explosive corrosive gases and dust, and there is no strong electromagnetic radiation source nearby. • The ground load-bearing capacity is not less than 600kg/m ², and the maintenance space around the equipment is not less than the specified size (A: 400mm, B: 400mm, C: 1000mm). • Power supply voltage must meet the requirements of AC380V three-phase four-wire system, and the grounding resistance of the protective ground wire is less than 4Ω. • The water quality of the water supply must meet the second-level water standard of the National Analytical Laboratory, and the solid impurity content is less than 1mg/L. The working environment temperature should be 5~ 30 ℃, humidity ≤ 85% R.H. • Pay attention to monitoring the refrigeration system protection device when the equipment is running, such as Compressor overheating, overcurrent, etc., to ensure safety. • Avoid unauthorized operation while the equipment is running to prevent damage to the system.
[A] No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
[A] First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
[A] After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.