Surface Moisture Detector

The surface moisture detector measures changes in conductivity or capacitance caused by moisture content by contacting the material surface with a sensor. It is used for monitoring paint drying, controlling moisture in paper production, and adjusting plastic injection molding processes to prevent bubbles or deformation.
Selection
When selecting, consider matching the probe frequency with the material type, ensuring the measurement range covers common humidity levels and the accuracy meets process requirements. Environmental temperature effects need compensation, with portable models suitable for on-site testing and fixed models for continuous production line monitoring. Check calibration certificates and protection ratings.

Terms

Standards

Instruments

Conductivity Detector principle and temperature and humidity compensation technology, measurement accuracy of +/- 0.5%, Response Time of 1 second, integrated design supports on-site rapid detection, suitable for a variety of grain moisture measurement.

$ 112.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00

Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.

$ 144.00

Conductivity Detector principle, Measurement range 2-95%, accuracy 0.1%, Response Time only 1 second, Humidity compensation technology to ensure measurement Stability, support MAX Maximum hold and automatic shutdown function.

$ 159.00

Measurement principle using Conductivity Detector method, Measurement range 8~ 40%, accuracy +/- 0.5%, with automatic compensation function of Temperature and Humidity, Response Time is only 1 second, Portable design weight about 203 grams, suitable for on-site rapid detection.

$ 264.00

Conductivity Detector principle and temperature and humidity compensation technology, measurement range 5-35%, accuracy +/- 0.5%, Response Time 1 second, integrated design is easy to carry, suitable for on-site rapid detection.

$ 148.00

Conductivity Detector measurement principle, measurement range 0-80%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation and backlight display, easy to quickly detect on site.

$ 144.00

Conductivity Detector measurement principle, Response Time is only 1 second, with temperature and humidity compensation technology, measurement accuracy +/- 2%, split design is easy to carry on site, support 3 sets of measurement code storage.

$ 230.00

Conductivity Detector measurement principle, measurement range 4~ 90%, Accuracy +/- 0.5%, Response Time 1 second, with temperature compensation and backlight display function, easy to quickly detect on site.

$ 223.00

Conductivity Detector Measurement principle, Measurement range 0-50%, Response Time less than 1 second, with temperature and humidity compensation function, split design for quick detection on site.

$ 230.00

The annular halogen lamp is used to heat the sample evenly and quickly, and the surface is not easily damaged. Capacity 100g, moisture measurement range 0.00~ 100%, and the general sample can be measured in a few minutes.

$ 388.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Conductivity Detector measurement principle, measurement range 0~ 84%, accuracy +/- 0.5%, Response Time 1 second, with temperature and humidity compensation technology, portable design weight only 265 grams, suitable for on-site rapid detection.

$ 160.00

Conductivity Detector measurement principle, measurement range 0~ 84%, resolution 0.1%, Response Time 1 second, with temperature and humidity compensation function, portable design weight only 203 grams.

$ 143.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Articles

The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Surface Absorbency Tester for Predicting Drying Speed of Printing Ink on Coated Paper
This article explores how the surface absorbency tester predicts the drying speed of ink on coated paper. Traditional methods rely on actual printing tests, which are time-consuming and difficult to quantify.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Application of Coating Rate Cardboard in the Determination of Coating Rate for Architectural Coatings
Coating rate card paper is a standardized substrate used to determine the spreading rate of architectural coatings. It features a smooth surface and stable parameters, which help minimize the influence of substrate variations and environmental factors associated with traditional methods.
Shore hardness tester measures the hardness of rubber sealing rings.
This article introduces the method of measuring the hardness of rubber sealing rings using a Shore durometer. The Shore durometer presses a needle into the rubber surface under spring force and converts the indentation depth into a hardness value, commonly using the A scale.
Salt spray test chamber for testing the corrosion resistance of plastic coatings.
The salt spray test chamber accelerates the testing of the corrosion resistance of plastic surface coatings by simulating a salt spray environment containing chloride ions. The test is conducted in accordance with international standards such as ASTM B117 or ISO 9227, and the process includes sample preparation, salt spray exposure, and result evaluation.
Gloss meter measures the surface brightness of packaging film.
This article introduces the principle and method of using a gloss meter to measure the surface glossiness of packaging films. The gloss meter quantifies the specular reflection capability of a surface in gloss units by measuring the ratio of reflected light from the sample to that from a standard plate.
Friction Coefficient Tester Measures the Slip and Openability of Films
This article introduces how to use a coefficient of friction tester to measure the slipperiness and openability of films. Slipperiness refers to the sliding characteristics of the film surface, while openability indicates the ease of separation between film layers. Both are crucial for processing efficiency in industries such as packaging.
Dyne Pen Selection, Surface Energy Test Range, and Pen Tip Lifespan
The dyne pen is used to evaluate the wettability of material surfaces, reflecting the effectiveness of treatments by measuring surface energy.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
The experimental sample of pressure-sensitive adhesive coated on the surface of PET labels using a film coater.
This article introduces the experimental method of applying pressure-sensitive adhesive to the surface of PET labels using a coating machine.
Heating coating machine is used for the doctor-blade coating of gel electrolyte films in zinc-ion batteries.
This article introduces the blade coating process for preparing gel electrolyte films for zinc-ion batteries using a heated coating mechanism. By controlling parameters such as temperature, coating speed, and gap height, this method enables the fabrication of films with uniform thickness and smooth surfaces.