Hole surface copper thickness Gauge

The hole and surface copper thickness tester measures the copper layer thickness of through-holes and surfaces on printed circuit boards using X-ray fluorescence. The instrument emits X-rays to excite copper atoms, generating characteristic X-rays, and calculates the thickness value by detecting the signal intensity. It is used to monitor the uniformity of electroplated copper during the PCB manufacturing process, ensuring the reliability of circuit conductivity.
Selection
When selecting, consider a measurement range covering 1-100 μm, equipped with multiple aperture sizes to adapt to different through-holes. It should include a substrate compensation function to eliminate medium interference and an automatic focusing system to ensure measurement stability. Ensure the device is equipped with a PCB-specific fixture and complies with ISO 3497 and ASTM B568 standards.

Terms

Standards

Instruments

The copper Cup ensures durability, the diaMeter of the flow hole is 4mm with the capacity of 100ml, and the measurement time range is 0~ 150s, which is suitable for conditional viscosity determination.

$ 141.00

It can measure the surface roughness of the hole with an aperture greater than 2mm, and the maximum depth is 9mm. It supports both flat and cylindrical measurement, and is suitable for a variety of special-shaped surface detection needs.

$ 425.00

It can be extended by 50mm, and up to 2 pieces can be installed to achieve 100mm deep hole measurement; it is suitable for deep hole internal surface roughness detection, and needs to cooperate with the measurement platform to ensure Stability.

$ 157.00

Providing stable copper Ion concentration standards to ensure ElectRode Measurement accuracy, 250ml Encasement meets the daily calibrating needs of the laboratory and is suitable for a variety of copper ion detection scenarios.

$ 110.00

Measurement range from 5mm, depth up to 22mm, suitable for a variety of Roughness Gauge to achieve profiled surface detection.

$ 275.00

Measurement range 0.00~ 5.00 ppm, accuracy +/- 0.05 ppm, using LED@575nm Illuminant, chemical reaction based rapid detection of copper Ion concentration, suitable for field and laboratory applications.

$ 215.00

Provide an additional one-year warranty period, which is applicable to Coating thickness Gauge pRoducts. It needs to be purchased simultaneously when purchasing the equipment and is not sold separately.

$ 122.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

The three-wheel structure design is adopted, and the center wheel contacts the film directly for reading. The measuring range is 0-500 μm and the indexing is 25 μm. It can perform nondestructive thickness measurement on plane and curved surface.

$ 186.00

Using 2.0MHz Frequency, specially designed for cast iron and other coarse crystal materials, concave curved surface structure is suitable for special workpiece shape, Measurement range covers 2.0~ 400.0mm, and the lower limit of pipe measurement is Φ 30 * 4mm.

$ 283.00

Using eddy Current thickness measurement principle, Measurement range 0-1000μm, resolution 0.1μm, minimum measurable convex curvature 3mm, with automatic shutdown and low voltage prompt function.

$ 267.00

Measurement range 0~ 1250μm, suitable for LEEB220 and LEEB222 Coating thickness Gauge, Abrasion Resistance is good, suitable for a variety of nonmagnetic Coating thickness detection.

$ 157.00

Using 90 ° Measurement Angles and eddy Current principles, accurate measurement of edge coatings, narrow tube coatings and small surface areas ensures stable and reliable measurement on complex geometries.

$ 235.00

Impact energy 11mN, Impact device mass 75g, can measure the inner surface of the inner hole or narrow space, suitable for a variety of specimen types and surface conditions.

$ 748.00

Measurement range 0-150 seconds, copper material is durable and in line with national standards, portable design is convenient for on-site rapid detection of Coating viscosity.

$ 123.00

Articles

Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Mechanical thickness gauge for measuring film thickness uniformity.
The mechanical thickness gauge assesses the uniformity of film thickness through contact measurement. During measurement, the probe contacts the sample under standard pressure, converting displacement into a thickness reading.
Selection of Coating Thickness Gauges Using Magnetic and Eddy Current Methods on Different Substrates
This article introduces two main methods for coating thickness gauges: the magnetic method and the eddy current method. When choosing a method, the key is to determine it based on the electromagnetic properties of the substrate.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Coulometric thickness gauge measures the sealing quality of anodic oxide films.
This article introduces a method for assessing the sealing quality of anodic oxide films using a coulometric thickness tester. The sealing quality affects the corrosion resistance and wear resistance of the oxide film. Based on electrochemical principles, the coulometric thickness tester evaluates the sealing effectiveness by measuring the electric charge required to dissolve the oxide film, providing objective and repeatable results.
Ultrasonic thickness gauge for detecting thick coatings and composite coatings.
Ultrasonic thickness gauges measure coating thickness using the principle of ultrasonic pulse reflection, calculating the result based on the propagation time of sound waves in the material and the speed of sound. When detecting thick coatings and composite coatings, challenges such as acoustic attenuation of the material, unknown sound speed, and signal recognition at multi-layer interfaces must be addressed.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Application of Electrolytic Thickness Tester in Quality Control of Precision Electroplating Layers
The electrolytic thickness gauge measures coating thickness through the principle of electrochemical dissolution, calculating based on Faraday's law, offering high accuracy and independence from calibration.
Ultrasonic Thickness Gauge Measures the Thickness of Flexible Packaging Materials
This article introduces the principles, technical points, and operational procedures for measuring the thickness of flexible packaging materials using an ultrasonic thickness gauge. It is based on the principle of ultrasonic pulse reflection, which calculates thickness by measuring the propagation time of sound waves through the material.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Magnetic thickness gauge measures the thickness of coatings on steel surfaces.
Magnetic thickness gauges are used to measure the thickness of non-magnetic coatings on ferromagnetic substrates such as steel, based on the principles of magnetic induction or changes in magnetic attraction. Prior to use, calibration should be performed according to relevant standards, and attention should be paid to factors such as substrate characteristics, workpiece shape, and surface conditions that may affect the measurements.
The principle of measuring dry film thickness with a coating thickness gauge
Coating thickness gauges measure dry film thickness through non-destructive methods, with commonly used principles including electromagnetic induction, eddy current, and ultrasonic methods.
Standard Operating Procedure for Zero Calibration and Substrate Calibration of Coating Thickness Gauges
This article introduces two key calibration methods for coating thickness gauges: zero-point calibration and substrate calibration. During operation, it is important to ensure that the probe is perpendicular, pressure is applied evenly, and regular calibration and recording are maintained. These steps effectively enhance measurement accuracy and meet industry standard requirements.