Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment, support microwave digestion pretreatment and acid rush.
Using high purity graphite PFA coating heating method, Temperature range RT +~ 400 ℃, monitoring accuracy +/- 0.5 ℃, digestion number of 20 holes, suitable for a variety of sample pretreatment, atomic absorption and other analytical instruments.
Temperature range RT +~ 400 ℃, high purity graphite + PFA coating heating method, monitoring accuracy +/- 0.5 ℃, suitable for a variety of sample pretreatment needs.
Using high purity graphite material and fuzzy PID temperature control technology, temperature control accuracy +/- 0.1 ℃, with over-temperature alarm, temperature self-setting and thermostatic timing function, panel size 400 * 300mm.
Using high purity graphite + PFA coating heating method, temperature control accuracy +/- 0.5 ℃, digestion number of 25 holes, suitable for microwave digestion pretreatment and acid treatment, supporting a variety of analytical instruments.
Graphite electRode to reduce Polarization effect, automatic temperature compensation to ensure accuracy, Measurement range EC 0-3999μS/cm, TDS 0-2000ppm, resolution up to 1μS/cm, suitable for harsh environments.
Temperature control accuracy of +/- 0.1 ℃, using fuzzy PID control technology, with over-temperature alarm and temperature self-tuning function, heating material is high purity graphite, panel size 600 * 400mm.
It can process 20 samples at the same time, the temperature control accuracy is +/- 1 ℃, and the corrosion resistance design and special oxidation resistance graphite block are used to ensure that the samples are heated evenly and have a long service life.
Temperature control accuracy +/- 0.1 ℃, Temperature range RT +~ 450 ℃, using fuzzy PID control to achieve fast stability and small overshoot, with over-temperature alarm and self-tuning function, heating material is high purity graphite.
PID microchip control to achieve +/- 0.5 ℃ temperature control accuracy, surrounded by heating to ensure that the temperature difference between holes ≤ +/- 1 ℃, high purity graphite heating material acid and alkali corrosion resistance, double-decked insulation design to improve safety and efficiency.
Using fuzzy PID temperature control technology, the temperature overshoot is small and the Stabilization time is fast; the temperature control accuracy reaches +/- 0.1 ℃, the panel size is 600 * 400mm; with over-temperature alarm and self-tuning function, to ensure the safety and accuracy of the experiment.
The vacuum pressure plate is made of pure bronze, the drying temperature can be adjusted from room temperature to 120 ℃, equipped with double drying stations and intelligent drainage system, and the paper uniformity can reach 96.
Equipped with a 200mm diaMeter pick-up cylinder and an 8-liter capacity, the manual Stirrer works in tandem with an 80-mesh forming filter for uniform Pulp distribution and efficient dehydrating.
Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.
Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.