Household temperature Tester

The household temperature tester senses changes in environmental heat through a thermal element and converts temperature signals into a digital display. It is used to monitor indoor and outdoor temperatures, as well as the operational status of refrigerators and air conditioners. It features Celsius to Fahrenheit conversion, with some models also including humidity detection.
Selection
When selecting, pay attention to the measurement range covering daily needs, with accuracy controlled within ±1℃. Prioritize LCD screen display and backlight functions, consider the power supply method and placement convenience. A waterproof design is suitable for kitchens and bathrooms, and long-term use requires attention to sensor stability.

Terms

Standards

Instruments

Using 4.0mm diaMeter nickel-chrome wire heating ring, Temperature range 500~ 1000 ℃ adjustable, apply 1N force and limit the pressing depth of 7mm, automatic control of sample movement and Timing function.

$ 1389.00

4.0Mm diaMeter nickel-chromium wire ring, Temperature range 500~ 1000 ℃ adjustable, apply 0.8~ 1.2N force and limit the pressing depth of 7mm, automatic timing of ignition and extinguishing time, Thermocouple 1050 ℃ high temperature resistance.

$ 1122.00

Using R2.5mm steel ball to apply 20N pressure, test at standard temperature for 60 minutes and then evaluate the thermal deformation performance of the material through measurement of Crane diaMeter, which is suitable for testing of various electrical components.

$ 196.00

The test bench has good anti-vibration performance, bearing weight of 80kg, angle adjustment range of 0-15 °, simple operation, and is suitable for mechanical Stability assessment of various household appliances.

$ 1101.00

The table diaMeter is 1000mm, the bearing capacity is 120kg, the angle adjustment range is 0-30 °, and the anti-vibration performance is good. It is suitable for mechanical Stability assessment of various household appliances.

$ 909.00

Test voltage 100-600V adjustable, short circuit current 1A +/- 0.1A, using platinum ElectRode high temperature corrosion resistance, drop height 30-40mm adjustable, time interval 30 +/- 1 seconds, automatically cut off the unqualified current.

$ 1542.00

Adopting pneumatic working mode, the test rate can be adjusted from 5 to 60 times per minute, with 4 independent test stations, capable of simultaneously testing switches and plugs and sockets, and supports current on-off and mechanical counting methods.

$ 1800.00

Wire-wound design can achieve one operation Spreader two or more Coatings, wet film thickness 4μm, application width 140mm, stainless steel material to ensure durability and accurate coating preparatory.

$ 157.00

Wire-wound structure can realize one operation Spreader two or more Coatings, wet film thickness 4μm, application width 255mm, stainless steel material is durable, is an ideal tool for preparing contrast samples.

$ 173.00

Adopt PLC + Touchscreen Control mode, flame height 12mm +/- 1mm adjustable, equipped with gas alarm and forced Air-Cooled system, three-dimensional adjustable fixture for easy observation and recording, stable and reliable.

$ 1848.00

Displacement 45L/min@0.7MPa, maximum pressure 0.8MPa, running noise 55dB, support custom pressure switch and optional oil-water separation, automatic drainage device to ensure stable air pressure and air mass.

$ 252.00

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, the studio is made of 304 stainless steel.

$ 6563.00

Temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using equilibrate temperature control to achieve high-precision stable temperature control, to meet a variety of standard test requirements.

$ 3338.00

Temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, using equilibrate temperature control to achieve high-precision temperature control, to meet a variety of industrial standard testing needs.

$ 4924.00

Built-in PT100 temperature sensor, temperature range 0~ 405 ℃, stainless steel shell, suitable for high temperature liquid temperature measurement, real-time accurate monitoring.

$ 106.00

Articles

Application of Laboratory Scraper Heating Coating Machine in Hot Melt Adhesive Coating
This article introduces the application of a laboratory blade heating coating machine in hot melt adhesive coating. It first explains the coating process and principles, including three stages—heat conduction, fluid shear, and surface wetting—as well as the influence of temperature on adhesive viscosity.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Application of Transparent Constant Temperature Water Bath in Visualization of Material Thermal Deformation
The constant temperature water bath provides a stable environment for observing the deformation of materials after heating by maintaining a constant and uniform temperature of the liquid medium.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
Rotation Speed of Sample Rack in Hot Air Aging Test Chamber on Color Fastness of Textiles
This article explores the influence of the rotation speed of sample racks in a hot air aging test chamber on the color fastness testing of textiles. The rotation speed affects the flow of hot air and temperature uniformity inside the chamber, thereby altering the heating conditions of the samples and leading to variations in color fastness results.
Temperature uniformity of high-temperature aging test chamber for UV resistance testing of inks
This article discusses how the temperature uniformity of high-temperature aging test chambers affects the accuracy of ink UV resistance testing. Temperature uniformity refers to the deviation in temperature at various points inside the chamber, with smaller deviations leading to more reliable test results.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.