Horizontal Low Temperature Thermostat

The horizontal low-temperature thermostatic bath uses compressor refrigeration and heater temperature control to maintain a stable low-temperature environment for the liquid inside the bath. It is used for low-temperature performance testing of materials, constant temperature control of chemical reactions, and sample preservation. It provides constant low-temperature conditions for paint curing experiments and ink cold resistance testing.
Selection
When selecting, consider the temperature range to cover experimental needs, the temperature control accuracy to match testing standards, the tank capacity to accommodate sample sizes, and the material's corrosion resistance to meet medium requirements, with comprehensive safety protection functions. Also, refer to equipment energy consumption and maintenance convenience.

Terms

Standards

Instruments

Temperature range -10~ 150 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, maintenance-free pressure pump supports horizontal and vertical stirring, multiple safety protection including low liquid level and over-temperature protection.

$ 1647.00

8L Tank Volume, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.05 ℃, equipped with maintenance-free pressure/suction pump, supports horizontal and vertical stirring to ensure uniform thermostatic.

$ 1332.00

Equipped with powerful pressure suction pump to support peripheral groove thermostatic, Temperature Fluctuation is only +/- 0.1 ℃, pump flow 4L/min, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure sample safety.

$ 1389.00

Equipped with a strong pressure suction pump to provide a thermostatic source for the peripheral Tank, temperature accuracy +/- 0.1 ℃, over-temperature and low temperature sound and light tracking alarm and liquid level protection functions ensure the safety and reliability of the sample.

$ 877.00

Temperature range -30~ 100 ℃, Temperature Fluctuation +/- 0.1 ℃, equipped with strong pressure suction pump and external connection port, support over-temperature low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 2362.00

Temperature range -10~ 95 ℃, using Air-Cooled fully enclosed Compressor, high cooling efficiency, low noise, the inner Tank is made of stainless steel, and the overall foaming and heat insulation performance of the low temperature Tank is good.

$ 1845.00

Adopt non-heat centrifugal circulating pump to avoid its own heat generation affecting the temperature field, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety functions, optional program temperature control and Communication interface.

$ 1317.00

Equipped with a strong pressure suction pump can provide a thermostatic source for the peripheral Tank, with a temperature accuracy of +/- 0.1 ° C, with over-temperature and low temperature sound and light alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 1098.00

Adopt non-heat centrifugal circulating pump to avoid temperature field interference, Temperature Uniformity up to +/- 0.05 ℃, with low water level protection and Compressor multiple safety protection, optional program temperature control and magnetic stirring function.

$ 1794.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, with a Temperature Uniformity of +/- 0.05 ° C, and is equipped with multiple Safety protection devices such as low water level anti-dry burning to ensure safe and reliable operation.

$ 1327.00

The use of non-heat centrifugal circulating pump to avoid affecting the temperature field, Temperature Uniformity of +/- 0.05 ℃, with low water level protection and Compressor multiple protection functions to ensure safe and stable operation.

$ 995.00

Temperature range -20~ 95 ℃, using Air-Cooled fully enclosed Compressor refrigeration, cooling fast low noise, the overall foaming performance of the Tank body is good, the inner Tank is made of stainless steel.

$ 2934.00

The use of non-heat centrifugal circulation pump to avoid the influence of self-heating, Temperature Uniformity +/- 0.05 ℃, equipped with multiple Safety protection such as low water level to prevent dry burning, to ensure the stability and safety of the experiment.

$ 2016.00

8L Tank Volume, Temperature range RT + 10~ 300 ℃, Temperature Fluctuation +/- 0.01~ 0.05 ℃, with low liquid level protection and automatic power failure recovery function, support internal and external circulation operation.

$ 1542.00

The non-heat centrifugal circulating pump is used to avoid its own heat generation affecting the temperature field, the temperature fluctuation is +/- 0.05 ℃, and it has low water level protection and Compressor multiple protection functions to ensure the safety and stability of the experiment.

$ 1067.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
High and low temperature alternating test chamber for measuring low-temperature embrittlement temperature of plastics
This article introduces how to use a high-low temperature alternating test chamber to determine the low-temperature brittleness temperature of plastics.
Thermal shock test chamber measures the thermal shock resistance of polymer films.
This article introduces how to test the thermal shock resistance of polymer films using a thermal shock test chamber. The test involves rapidly switching the film between high and low temperatures to simulate the drastic temperature changes that may occur in actual use, thereby generating thermal stress within the material.
Thermal Shock Test Chamber Measures Film's Temperature Change Resistance
The thermal shock test chamber creates thermal stress inside the film by rapidly switching between high and low temperature environments, testing its resistance to temperature changes. During the test, key parameters such as temperature range and dwell time need to be set, and the film is observed for issues such as cracking or performance degradation.
Flash point tester for determination of closed cup flash point of varnish
This article introduces the method for determining the closed-cup flash point of varnish using a flash point tester. The flash point refers to the minimum temperature at which the vapor on the surface of the varnish ignites momentarily when exposed to a flame after heating. It is a crucial indicator for assessing the fire risk during its production, storage, and transportation.
Thermal Shock Test Chamber Evaluates Coating Thermal Stability
The thermal shock test chamber simulates sudden temperature changes by rapidly switching between high and low temperature environments, used to evaluate the thermal stability of coatings. In practical applications, coatings may develop internal stresses due to drastic temperature fluctuations, leading to issues such as cracking and peeling.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.
Key Points for Selecting Low-Temperature Test Chambers in Rubber and Plastic Brittleness Temperature Testing
In the testing of brittle temperature for rubber and plastics, the selection of a low-temperature test chamber must ensure testing accuracy. When choosing the equipment, it is essential to consider various parameters comprehensively based on the requirements of the testing standards.
The flash point tester measures the safety baseline value of the solvent.
The flash point refers to the minimum temperature at which the vapor of a flammable liquid can be ignited. It is not a fixed value but depends on the testing method and instrument. Data measured by flash point testers serve as a critical basis for evaluating the fire risk of solvents and establishing standards for safe storage and operation.
Safety Regulations for Closed Cup and Open Cup Methods for Testing the Flash Point of Coatings.
This article introduces two main testing methods for the flash point of coatings: the closed-cup method and the open-cup method. The flash point refers to the lowest temperature at which the vapor of a coating momentarily ignites upon encountering an open flame, serving as a critical indicator for assessing the risk of fire and explosion.
Tensile Testing Machine Evaluates High and Low Temperature Tensile Properties of Hot Melt Adhesive
This article introduces how to use a tensile testing machine to test the tensile properties of hot-melt adhesives at different temperatures. The performance of hot-melt adhesives varies with temperature: they may soften at high temperatures and become brittle at low temperatures.
The essential difference between thermal shock test chambers and high-low temperature alternating test chambers.