Linear High and Low Temperature Test Chamber

The linear high-low temperature test chamber controls the temperature to rise or fall at a set constant rate through programmed settings, simulating the tolerance of materials in environments with temperature variations. It is used to detect performance changes such as deformation and aging of products like coatings and plastics under temperature differences.
Selection
When selecting, it is necessary to match the size of the object being tested to determine the inner chamber volume, confirm the temperature range based on the material's temperature resistance, choose the heating and cooling rate in accordance with the test standard requirements, and select the power specifications and ventilation conditions according to the installation site.

Terms

Standards

Instruments

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and identification inspection.

$ 8497.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 6254.00

Temperature range -40~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high and low temperature cycle change test, suitable for material performance inspection and aging test, equipped with multiple safety protection devices.

$ 6431.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature alternating cycle test, suitable for pRoduct design improvement and aging test, in line with a number of national standards.

$ 6770.00

Temperature range -60~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature Reliability test, support aging test, in line with a number of national standards.

$ 5947.00

Temperature range -60~ 150 ℃, studio volume 1000L, stainless steel studio and high temperature insulation material, support high and low temperature cycle change test, in line with a number of national standards.

$ 9352.00

Temperature range -40~ 150 ℃, studio volume 150L, suitable for high temperature and low temperature Reliability test, in line with a number of national standards, aging test and constant temperature test.

$ 5431.00

Temperature range -70~ 150 ℃, studio volume 80L, Temperature Uniformity +/- 1.0 ℃, suitable for high temperature and low temperature cycle change test, support aging test and a variety of standard requirements.

$ 5560.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature and low temperature cycle change test, suitable for aging test and material performance inspection.

$ 7109.00

Temperature range -20~ 150 ℃, Temperature Uniformity +/- 1.0 ℃, support high temperature, low temperature and constant temperature test, suitable for Reliability test, equipped with multiple protection devices and safety system.

$ 4818.00

Temperature control range -60~ 150 ° C, studio volume 80L, suitable for high temperature and low temperature cycle change testing, in line with a number of national standards, equipped with perfect protection devices and imported refrigeration system.

$ 5043.00

Temperature range -20~ 150 ℃, volume 225L, stainless steel studio and high-efficiency insulation material, support high and low temperature cycle test, suitable for aging test and pRoduct performance inspection.

$ 5399.00

Temperature range -20~ 150 ℃, studio volume 408L, suitable for high temperature and low temperature Reliability test, support constant temperature test, in line with a number of national standards.

$ 6076.00

Adopt unique equilibrate temperature control method to achieve high precision temperature control, temperature range -40~ 130 ℃, Temperature Uniformity ≤ + 2 ℃, the studio is made of 304 stainless steel.

$ 6563.00

Temperature range -80~ 130 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using a unique equilibrate temperature control method to achieve high-precision temperature control, the studio is made of 304 stainless steel.

$ 6575.00

Articles

Application of Linear Abrasion Tester in Testing Scratch Resistance of Printing Ink Coatings on Packaging
This article introduces the principle, method, and application of the linear abrasion tester in testing the scratch resistance of packaging printing ink coatings.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.
A Comprehensive Guide to Selecting an Electronic Balance
This article introduces the key points for selecting an electronic balance. It provides a detailed list of core parameters such as accuracy class, repeatability, and linearity error, and explains their impact.
Selection of abrasion testing machine is based on the wear form, choosing between linear or rotational types.
When selecting a wear testing machine, the first step is to determine based on the primary wear forms the material actually encounters.
Selection criteria for linearity error of semi-micro balances
The linearity error of a semi-micro balance refers to the deviation between the actual displayed value and the theoretical value within its weighing range. This indicator directly affects the accuracy of weighing, which is particularly important in scenarios requiring high-precision measurements, such as material analysis or environmental monitoring.
Laboratory Application Scenarios of Milligram Precision Balances
The milligram precision balance can accurately weigh up to 0.001 grams, primarily utilizing electromagnetic force compensation technology, and its performance is related to parameters such as repeatability and linearity error.
The necessity of explosion-proof high and low temperature test chambers in lithium battery testing
Lithium batteries pose a risk of thermal runaway or even explosion when tested under extreme temperatures. Explosion-proof high-low temperature test chambers, designed with pressure relief structures, explosion-proof electrical components, and intelligent monitoring systems, can safely release energy and ensure the safety of the testing process.