Double Glass Reactor

The double-layer glass reactor consists of inner and outer layers of glass, with a circulating medium passed through the interlayer to regulate temperature, while chemical reactions take place in the inner container. It is used for material mixing, distillation, or synthesis processes in the laboratory, accommodating the need for temperature variations.
Selection
When selecting, consider matching the properties of the reactants with the material's corrosion resistance, determine the capacity based on the experimental scale, ensure the temperature range covers the process requirements, and guarantee the stability of operation through the stirring method and sealing. Also, ensure interface compatibility with existing equipment.

Terms

Standards

Instruments

High Accuracy Microcomputer Temperature Controller, Temperature Fluctuation +/- 0.3 ℃, Temperature range 5 ℃~ 60 ℃, double-decked Glass observation window for easy observation, Mirror stainless steel studio and removable shelf to enhance the convenience of use.

$ 753.00

Adopt double-decked tempered Glass door observation window and heat-resistant silicone rubber sealing ring, Temperature Uniformity +/- 2 ℃, Fluctuation ≤ +/- 0.5 ℃, to ensure the temperature insulation and temperature control accuracy in the box.

$ 404.00

Double-decked Glass Viewing Windows facilitate viewing of fostered items, High Accuracy Microcomputer ThermoMeter ensures temperature fluctuations of +/- 0.3 ° C, 304 stainless steel liner and removable shelves enhance durability and flexibility.

$ 696.00

Temperature range Tr + 5~ 65 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, using double-decked tempered Glass door observation window and heat-resistant silicone rubber sealing ring to improve temperature insulation and sealing, suitable for a variety of foster needs.

$ 365.00

Measurement range 5-55 ℃, ceramic sand core salt bridge material, Glass shell design, Dimension Φ 10 × 120mm, providing stable reference potential.

$ 91.00

Measurement range 5-55 ℃, Glass shell design ensures stable and reliable measurement performance.

$ 91.00

Temperature range RT + 50~ 150 ℃, volume 25L, equipped with double-decked tempered Glass observation window to ensure Temperature uniformity and operational safety, suitable for drying temperature-sensitive samples.

$ 412.00

Using quartz Glass material, the distillation process does not contact with metal to ensure the mass of pure water; Heating power 3000W, water output of 2500ml/h, suitable for experimental preparatory secondary distillation water.

$ 740.00

Temperature range 50-250 ℃, Inner Chamber dimensions 560 * 640 * 600mm, equipped with double-decked tempered bulletproof glass observation window and vacuum electromagnetic inflatable valve to ensure safe operation and Temperature uniformity.

$ 3928.00

Glass thickness and air interlayer thickness can be measured at the same time. Glass thickness range is 70mm, air interlayer range is 34mm, light and portable operation is simple.

$ 341.00

Equipped with microwave and ultrasonic synergy function, 2000ml large-capacity reactor and 1800W ultrasonic power, support platinum resistance accurate temperature measurement and magnetic stirring, and realize multi-mode chemical reaction control.

$ 15887.00

Temperature range RT + 50~ 250 ℃, Inner Chamber dimensions 415 * 370 * 345mm, equipped with double-decked tempered bulletproof glass observation window, intelligent digital display system to precisely control the temperature, stainless steel liner corrosion resistance easy to clean.

$ 740.00

Glass shell material, temperature range of 0-70 ℃, Dimension Φ 12 × 120mm, equipped with U-shaped fork connector, suitable for a variety of analytical instruments.

$ 102.00

Using laser reflection principle to achieve one-sided measurement, accuracy of 0.1mm, can simultaneously obtain multi-layer Glass and air layer Film thickness, support automatic and manual mode, adapt to three glass two Chambers, laminated Glass and other materials.

$ 667.00

The interlayer vacuum design is easy to keep warm, the test capacity is about 300ml, the upper and lower holes go in and out for easy connection of the thermostatic Bath, easy to use and easy to clean.

$ 146.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.