Air Permeability Measurement Device

The air permeability tester measures the gas transmission rate of materials using the differential pressure method. It creates a stable pressure difference on both sides of the sample, allowing gas to permeate from the high-pressure side to the low-pressure side. Sensors record pressure changes to calculate the air permeability. It is used to test the barrier properties of materials such as plastic films, paper, and coatings, ensuring the sealing quality of packaging.
Selection
When selecting, consider the material type in relation to the testing standards: choose a low-pressure range for thin films and a high-pressure model for thick materials. Confirm that the test gas type matches the sensor. Select manual or automatic models based on production needs. Verify the validity of the instrument's calibration certificate. Compare the test chamber size to ensure it is compatible with the sample specifications.
Measurement method

Terms

Standards

Instruments

Suitable for 1 × 10-2 - 1 × 102um/(Pa. S) Air Permeability Range, Measurement accuracy of +/- 1ml (< 100ml), 304 stainless steel fixture and silicone sealing to ensure long-term corrosion resistance and sealing, support multi-gear measurement.

$ 1009.00

Measurement range 0~ 1000ml/min, pressure difference 0.1~ 2.0kpa, stainless steel end cap and pure copper valve anti-corrosion structure, built-in fixture to avoid rubber pad peeling, suitable for a variety of materials Air Permeability accurate test.

$ 1200.00

Measurement range 0~ 1000ml/min or 0~ 17µm/(Pa · s), test area 10.0 +/- 0.05cm ², differential pressure accuracy +/- 0.01kPa, clamp ring coaxiality less than 0.05mm, suitable for medium Air Permeability paper testing.

$ 961.00

Measurement range 0~ 1000ml/min, test area 10cm ², test area pressure difference 1kPa, suitable for a variety of industrial paper ventilation performance detection.

$ 935.00

Measurement range 0~ 1000ml/min, test area pressure accuracy of +/- 0.01kPa, equipped with 10cm ² standard test area and 35.68mm clamping ring, support different duration test.

$ 1098.00

Vacuum Level 100 or 200 mm water column constant test, Measurement range 0-1000ml/min, test area 10cm ², support a variety of paper ventilation performance evaluation.

$ 1151.00

Vacuum principle measurement paper breathability performance, Measurement range 0-1000ml/min, test area of 10cm ², suitable for a variety of industrial paper mass detection.

$ 1134.00

The test area is 30cm ², suitable for self-supporting and non-self-supporting coating testing, and the permeability of water vapor or Miscellaneous gaseous substances to the film can be determined by the wet Cup method or the dry Cup method.

$ 135.00

The test area is 50cm ², which supports two test modes of wet Cup method and dry Cup method, which can measure the permeability of water vapor and Miscellaneous gaseous substances to the film, and is suitable for coating performance evaluation under different environment conditions.

$ 196.00

Test area of 10cm ², in line with a number of international standards, support self-supporting and non-self-supporting coating testing, can be measured by wet Cup method and dry Cup method of water vapor permeability, suitable for different environmental conditions.

$ 119.00

Measurement range 0~ 2500mL/min, accuracy of 0.01μm/Pa • s, support a variety of test methods, automated operation to ensure accurate and reliable results.

$ 4269.00

Measurement range 0.3~ 45m/s, accuracy +/- 3% +/- 0.1dgt, support air volume and air temperature measurement, with data storage and backlight display functions, suitable for a variety of environment monitoring needs.

$ 124.00

Glass thickness and air interlayer thickness can be measured at the same time. Glass thickness range is 70mm, air interlayer range is 34mm, light and portable operation is simple.

$ 341.00

High Accuracy air-floating hydrostatic bearing structure, spindle accuracy +/- 0.025μm, system accuracy 0.06μm, with automatic identification of interruptions and removal of notches, support part of the arc measurement and a variety of filter band selection.

$ 12184.00

The instrument supports two tilt angle tests of 10 ° and 30 °, and can measure key paraMeters such as slip, re-leakage and leakage, and simulate real use scenarios to evaluate instantaneous absorption capacity.

$ 440.00