VOC Mass Detector

VOC mass detectors measure the concentration of volatile organic compounds in the air using photoionization or gas chromatography. They are used to monitor the volatilization of organic solvents during the production of paints, inks, and other materials, helping to control air quality in workshops.
Selection
When selecting, consider that the detection range must cover the target compounds, the response speed should match the process requirements, the sensor lifespan and maintenance cycle, the explosion-proof rating should suit the on-site environment, and the data output interface must be compatible with the existing system.

Terms

Standards

Instruments

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch high definition display, supports 1-6 Sensor configurations, with 4-20mA, RS485 and other signal output, Protection Rating up to IP65, Response Time ≤ 20 seconds.

$ 545.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.

$ 189.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and linkage control.

$ 332.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; with flameproof structure and a variety of signal output, support remote monitoring and customized range, through a number of international safety certifications.

$ 332.00

Using PID Sensor technology, range 0~ 500ppm, resolution 0.1ppm, support 1-6 Sensor expansion, with a variety of signal output modes, including 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for harsh environments.

$ 1818.00

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Adopt PID light ion detection principle, range 0-50ppm, Response Time ≤ 30S, with explosion-proof structure, multiple signal output and remote alarm function, support customized wireless transmission.

$ 1171.00

Adopt PID photoion detection principle, range 0-50ppm, Response Time ≤ 30S, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote monitoring capability.

$ 1171.00

Pump-suction sampling and PID Photoion Sensor technology, Response Time ≤ 20 seconds, resolution of 0.001 ppm, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 2557.00

Using ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³, equipped with independent variable frequency wind speed adjustment device, Modular design is easy to maintain, and the operating power is as low as 1.2kw.

$ 25602.00

Equipped with 2.4-inch high definition color screen, supports 1-6 Sensor expansion, with 4-20mA and RS485 output, Response Time ≤ 20 seconds, Protection Rating IP65, suitable for harsh industrial environments.

$ 583.00

Adopt ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³; equipped with independent variable frequency wind speed adjustment device, the wind speed range is 0.1-1 m/s; Modular design is easy to maintain, and the integrated gas supply purification system is easy to operate.

$ 35348.00

Pump-suction sampling and PID photoion technology, detection accuracy of +/- 3%, Response Time ≤ 20 seconds, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 1532.00

High-precision Sensor is used to detect PM2.5 concentration, Response Time is instantaneous, Sensitivity can be adjusted to 5PPM, with sound and light alarm and automatic warm-up function, continuous work for 5 hours.

$ 157.00

Articles

Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Standard Procedure for Printability Tester in Evaluating Ink Transfer Performance
This article introduces the standard procedure for evaluating ink transfer performance using a printability tester. The transfer performance of ink directly affects print quality, and standardized operations can enhance the reliability of test results.
Gelation Time Tester in the Testing of Thermosetting Resin Curing Process
The gel time tester is used to measure the transition time of thermosetting resins from a liquid state to a gel state, which is crucial for controlling the curing process and product quality.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
Sealing tester measures the pressure resistance and leakage of composite film bags.
This article introduces how to use a seal tester to evaluate the pressure resistance and leakage performance of composite film bags. The test primarily involves applying controlled pressure inside the packaging and observing pressure changes or leakage to assess the quality of the seal.
Thermogravimetric Analyzer for Measuring Moisture and Volatiles in Polymer Materials
Thermogravimetric analyzers determine the moisture and volatile content in polymer materials by measuring the mass changes during the heating process.
Rubber abrasion tester measures tire wear resistance.
The rubber abrasion tester evaluates wear resistance by simulating the friction between tires and road surfaces. It uses a grinding wheel to rub against rubber specimens under set conditions, measuring mass loss and converting it to volume loss to assess material performance.
Quantitative Measurement of Carbon Black Content in Rubber by Thermogravimetric Analyzer
Thermogravimetric analyzers measure changes in sample mass through programmed temperature control, enabling the quantitative determination of carbon black content in rubber. During the experiment, the rubber is first heated in an inert atmosphere to decompose it, leaving the carbon black intact. The atmosphere is then switched to an oxidizing environment to oxidize the carbon black. The carbon black content is calculated based on the mass loss.
Melt Flow Index Tester for Measuring Plastic Flowability to Control Process
A melt flow indexer evaluates the melt flow rate of plastics by measuring the extrusion mass or volume under specific temperature and load conditions.
Thermogravimetric Analyzer Measures Thermal Stability of Plastic Films
This article introduces how to test the thermal stability of plastic films using a thermogravimetric analyzer. It first explains the fundamental principle of the instrument, which assesses the thermal properties of materials by measuring changes in sample mass as a function of temperature.
Differential Scanning Calorimetry for Measuring the Melting Temperature of Thin Films
Differential scanning calorimetry analyzes thermal transitions in materials by measuring the heat flow difference between the sample and a reference. When determining the melting temperature of thin films, the sample must be uniformly prepared, with a mass between 3 and 10 milligrams. Testing is typically conducted at heating rates ranging from 5 to 20°C/min under a nitrogen protective atmosphere.
Selection of impact head diameter and drop hammer mass combination for paint film impact tester
When selecting the impactor diameter and drop hammer mass for a paint film impact tester, the key is to balance the impact energy and pressure.
The sample for coating adhesion assessment is uniformly applied using a film applicator.
This article emphasizes that the use of a film applicator to prepare uniform coating samples is crucial, and it elaborates on how the working principle of the film applicator, coating speed, and other parameters affect the quality of the coating.
The coating machine applies planar optical waveguide cladding material to the surface of optical fibers.
This article introduces the technique of using a coating machine to apply planar optical waveguide cladding materials onto the surface of optical fibers. It analyzes the characteristics of the cladding materials, such as viscosity and surface tension, and their impact on coating quality.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.