Stationary Mounted Mixer

A fixed mixer uses a motor to drive stirring blades that rotate inside a container, ensuring uniform mixing of materials. It is used in laboratories for the preparation of samples such as coatings and inks, guaranteeing consistent distribution of components.

Instruments

32 5ml centrifuge tubes can be installed vertically on both sides, using a vertical installation design, suitable for HT-X100 swirl/spin Mixer, improving Sample Handling efficiency.

$ 149.00

Double-sided horizontal mounting design can accommodate 40 centrifuge tubes simultaneously, compatible with 1.5ml and 2.0ml specifications, suitable for swirl/spin Mixer for efficient Sample Handling.

$ 149.00

The double-sided horizontal mounting design can simultaneously accommodate 16 50ml centrifuge tubes, which are suitable for standard 50ml tube specifications and provide a stable and reliable sample carrying platform.

$ 149.00

44 1.5ml or 2.0ml centrifuge tubes can be installed vertically on both sides, providing efficient Sample Handling capability, adapting to a variety of centrifuge tube specifications, and improving the convenience of experimental operation and space utilization.

$ 149.00

12 10ml or 15ml centrifuge tubes can be installed vertically on both sides, providing stable fixation and efficient mixing. They are suitable for a variety of centrifuge tube specifications and enhance the convenience of experimental operation.

$ 149.00

Wall-Mounted waterproof structure is equipped with PTFE anti-clogging dialysis membrane, supports 0.0-14 pH Measurement range and +/- 0.2pH accuracy, alarm point can be set at 3-11pH, LED light reminder when the setting exceeds +/- 0.5pH, extending ElectRode life.

$ 272.00

Adopting rotary oscillation design, Frequency 3000rpm, pendulum amplitude 5mm, suitable for small containers such as testtube and Colorimetric tube, it can efficiently handle the experimental requirements of large chemical reactions and few solutions.

$ 125.00

Using the rotary oscillation mode, Oscillation Frequency up to 3000 rpm, swing amplitude of 5mm, through smooth contact to achieve rapid mixing, speed can be adjusted with pressure, suitable for a variety of laboratory applications.

$ 133.00

Using stepless speed regulation technology, Speed range 0~ 2800rpm, turnover diaMeter 4mm, support point and continuous Operating Mode, high performance motor to ensure rapid mixing and low noise.

$ 208.00

Rotation speed 2500rpm, can handle 2000ml volume sample, integrated magnetic stirring, vortex mixing and microplate oscillation multi-function.

$ 396.00

Double-sided horizontal mounting design can accommodate 40 5ml centrifuge tubes, suitable for standard centrifuge tube specifications, improving Sample Handling efficiency and ease of operation.

$ 149.00

Support simultaneous detection of 4 gases, integrated temperature and Humidity detection, with Internet of Things remote monitoring function, Response Time T90 ≤ national standard, Protection Rating IP66, suitable for a variety of Installation methods.

$ 301.00

With magnetic stirring function, the maximum stirring capacity of 2000ml, Speed range 200-2500rpm, vibration range 4.5mm, support point and continuous operation mode switching.

$ 359.00

Simultaneously detect 4 kinds of gases and integrate temperature and Humidity detection, adopt dual temperature Humidity compensation design, Response Time T90 ≤ national standard, with a variety of wireless communication options and remote paraMeter configuration functions.

$ 635.00

Support simultaneous detection of 4 kinds of gases, integrated temperature Humidity detection, with 10 Meters visual distance high definition color screen, dual temperature Humidity compensation design, Response Time T90 ≤ national standard, Protection Rating IP66.

$ 935.00

Articles

Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Temperature Oscillation Suppression in Reflux Synthesis Using Laboratory Stirring Heating Mantles
This article explores the causes and suppression methods of temperature oscillations in laboratory heating mantles during reflux synthesis.
Standard ink film preparation with a blade coater before tack testing of offset printing inks.
This article introduces the method of preparing a standard ink film using a blade coater before testing the tackiness of offset printing inks. It explains the principle of controlling ink film thickness by adjusting the blade gap and details the operational steps from securing the substrate and applying the ink to completing the coating process.
Heat Deflection Temperature Tester for Measuring the Thermal Resistance of Carbon Fiber Reinforced Plastics
This article introduces the method of testing the heat resistance of carbon fiber-reinforced plastics using a heat deflection temperature tester. The instrument applies a fixed load to the material while increasing the temperature, measuring the temperature at which the material reaches a specified deformation, thereby evaluating its short-term resistance to thermal deformation.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Heat Sealing Tester Determines the Optimal Heat Sealing Temperature for Films
A heat seal tester is used to determine the optimal heat sealing temperature of films to ensure the sealing strength and integrity of packaging. During testing, by setting a temperature gradient and fixing parameters such as pressure and time, samples are heat-sealed at different temperatures, and then their strength is measured.
The Taber Abraser evaluates the wear resistance of coatings.
The Taber abrasion tester simulates surface wear of materials through rotational friction, used to evaluate the wear resistance of coatings. During testing, a grinding wheel is used to rub the specimen under a fixed load, and performance is quantified by measuring mass loss or thickness changes after a specified number of cycles.
Pencil Hardness Tester for Rapid Evaluation of Coating Surface Hardness
The pencil hardness tester is a tool used for rapidly assessing the relative hardness of coating surfaces through standardized scratch tests. It employs a series of pencil leads with known hardness levels, which are drawn across the coating under a fixed load and angle. The hardness grade, ranging from 6B to 9H, is determined based on whether a permanent scratch is produced.
Method for determining the dynamic viscosity of varnish using a falling ball viscometer
This article introduces a method for measuring the dynamic viscosity of varnish using a falling-ball viscometer. It is based on Stokes' law, which calculates viscosity by measuring the time required for a standard small ball to fall a fixed distance in a vertical glass tube filled with varnish.
Circle Method Adhesion Tester for Evaluating the Adhesion of Paint Coatings by the Circular Rolling Line Method
The rolling circle method is a technique for testing the adhesion of paint coatings using a circle-drawing instrument. The instrument employs a fixed-load stylus to draw a continuous circular trace on the coating at a constant speed, and the adhesion level is assessed based on the peeling condition of the scratch.
Pencil Hardness Plan Outstanding Paint Film Pencil Hardness Grade
The pencil hardness test is a method for evaluating the scratch resistance of paint films. It involves using a series of pencils with known hardness levels to scratch the coated surface under fixed conditions. The hardness grade of the coating is determined by observing whether permanent scratches are produced.
Schopper air permeability tester measures paper air permeability.
The Schopper air permeability tester measures the air permeability of paper based on Poiseuille's law, calculating the permeability by either the air flow rate under a constant pressure difference or the pressure difference at a fixed flow rate.
Application of Film Pencil Hardness Tester in Coating Scratch Resistance Testing
The paint film pencil hardness tester is an instrument used to evaluate the scratch resistance of coatings. It works by scratching the surface of the coating with a pencil of known hardness under a fixed load, and then assessing the hardness grade based on whether scratches are produced.
Operation Specification for Circular Scratch Adhesion Tester
The circle method adhesion tester is used to evaluate the adhesion strength between coatings and substrates. Before operation, it is necessary to inspect the instrument, prepare samples, and control the ambient temperature and humidity. During testing, the sample should be secured, appropriate load and scratch spacing should be selected, and the stylus should be moved at a constant speed to create a circular scratch.
Stormer viscometer measures the KU viscosity of latex paint
This article introduces the method of measuring the KU viscosity of latex paint using a Stormer viscometer. The viscometer measures the load required to maintain a fixed rotational speed through the rotation of its paddle, thereby calculating the KU value, which is related to the application and storage properties of the coating.