Temperature-Humidity Conditioning Chamber

The temperature and humidity chamber controls the internal temperature and humidity through a heating/cooling system and humidification/dehumidification devices, and is used to simulate environmental conditions for testing material performance. It is commonly used in weathering tests for products such as coatings and paper.
Selection
When selecting, consider that the temperature range covers testing requirements, humidity control accuracy matches standards, chamber dimensions accommodate sample volume, material corrosion resistance suits long-term use, and the operation interface aligns with user habits.

Terms

Standards

Instruments

Adopt equilibrate Conditioning Control system, Temperature and Humidity control range -60~ 150 ℃ and 20~ 98% R.H., equipped with imported Compressor and environmentally friendly refrigerant, with automatic calculation control and multiple Safety protection to ensure uniform and stable testing.

$ 3317.00

Adopt TMHM equilibrating Conditioning method, temperature control accuracy up to +/- 0.5 ℃, equipped with imported Humidity Sensor and independent temperature limit alarm system, 25mm test hole on the left for easy operation.

$ 6785.00

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% R.H., with multi-stage heating pipe and circular split humidifier, with energy-saving regulating valve to achieve segmented control, ensure uniform and stable heat preservation Humidity.

$ 2736.00

Adopt equilibrating Conditioning Control system, Temperature and Humidity control range -20~ 150 ℃ and 20~ 98% R.H., with multi-stage heating and energy saving functions to ensure long-term accurate operation.

$ 5039.00

The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.

$ 5110.00

Adopt equilibrating Conditioning Control system, with multi-stage intelligent output to ensure stable Humidity. Temperature range -60~ 150 ℃, Humidity Control Range 20~ 98% R.H., with energy saving function and comprehensive protection system to ensure long-term accurate operation.

$ 6330.00

Adopt equilibrate Conditioning Control system, Temperature and Humidity control range -20~ 150 ℃ and 20~ 98% RH, equipped with imported Compressor and multi-stage heating pipe, with High Accuracy PID calculation and comprehensive protection function to ensure stable and reliable testing.

$ 3102.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Adopt equilibrate Conditioning Control system, Temperature and Humidity control range -40~ 150 ℃ and 20~ 98% R.H., equipped with imported Compressor and environmental protection refrigerant, with automatic calculation control and High Accuracy Stability, avoid test dead angle.

$ 2655.00

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, equipped with imported Compressor and multi-stage PID calculation, ensure uniform and stable heat preservation Humidity, energy saving and high efficiency.

$ 2457.00

Adopt equilibrate Conditioning Control system, Temperature and Humidity control range -40~ 150 ℃ and 20~ 98% R.H., with energy saving function, built-in automatic High Accuracy PID calculus control to ensure stable operation.

$ 2789.00

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, with multi-stage heating and energy-saving control valve, special air circulation design to ensure uniform temperature, built-in a variety of protection functions to ensure long-term stable operation.

$ 2462.00

Using multi-stage programmable PID controller and equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and a variety of protection functions.

$ 3630.00

Adopt equilibrating Conditioning Control system, Temperature range -60~ 150 ℃, Humidity Control Range 20~ 98% R.H., with multi-stage intelligent output and energy saving function, built-in automatic High Accuracy PID calculus control, ensure uniform and stable heat preservation Humidity.

$ 2779.00

Adopt equilibrate Conditioning Control system, Temperature range -40~ 150 ℃, Humidity control 20~ 98% R.H., with multi-stage intelligent output and energy saving function, built-in High Accuracy Sensor to ensure uniformity, support RS232 remote control, Compressor adopts imported brand to ensure reliable cooling.

$ 3209.00

Articles

The Application of Contact Angle Measurement Instruments in the Study of the Relationship Between Ink Printing Wettability and Substrate Surface Tension
This article introduces how a contact angle measuring instrument is used to study the relationship between wettability and substrate surface tension in ink printing. It first explains the principle, assessing the degree of wettability through the size of the contact angle, where an angle less than 90 degrees indicates good wettability.
The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
The friction color fastness tester measures the amount of color transfer under dry and wet abrasion conditions for ink.
This article introduces a method for testing the amount of ink color transfer using a friction colorfastness tester, simulating both dry and wet rubbing conditions. Dry rubbing involves rubbing the ink surface with a dry white cotton cloth, while wet rubbing uses a white cotton cloth moistened with water.
Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Determination of Thermal Decomposition Temperature and Inorganic Filler Content in Ink by Thermogravimetric Analyzer
This article introduces how to determine the thermal decomposition temperature and inorganic filler content of ink using a thermogravimetric analyzer. During the test, a small amount of ink sample is heated in a nitrogen or air atmosphere, and the mass change curve is recorded.
Application of High-Temperature Universal Testing Machine in the Study of Hot Modulus of Rupture of Refractory Materials
This article introduces the application of a high-temperature universal testing machine in measuring the hot modulus of rupture of refractory materials. It explains the working principle, testing procedure, and key parameters of the testing machine, such as the effects of heating rate, holding time, and loading rate.
How is a high-temperature muffle furnace applied in ash determination?
This article introduces the application of high-temperature muffle furnaces in ash determination. The principle of ash determination involves completely burning the sample at high temperatures, leaving behind inorganic mineral residues. The muffle furnace provides a stable and controllable thermal environment, ensuring accurate results.
Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
Laboratory Drying Oven Model Selection - Difference Between Forced Air Convection and Non-Forced Air Convection
This article on the selection of laboratory drying ovens primarily introduces the differences between forced convection (air-blowing) and natural convection (non-air-blowing) drying ovens.
Incubator Selection: Applicability of Temperature Control Range and Function Configuration
This article mainly introduces the compatibility between temperature control range and functional configuration that need to be considered when selecting an incubator.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Optimization of mixing efficiency of vortex mixer in liquid-liquid microextraction
This paper explores how to enhance mixing efficiency in liquid-liquid microextraction by adjusting the operating parameters of a vortex mixer.
Rapid temperature change high and low temperature test chamber for thermal fatigue evaluation of PCB board solder joints.
This paper discusses the application of rapid temperature change high and low temperature test chambers in evaluating the thermal fatigue of PCB board solder joints. Solder joint fatigue is primarily caused by differences in material thermal expansion, and the test chamber simulates thermal stress through temperature cycling to accelerate the fatigue process.
Application of Three-Chamber High and Low Temperature Test Chambers in Rapid Temperature Cycling for Electronic Products
The three-chamber high-low temperature test chamber is used for reliability testing of electronic products, enabling rapid temperature transitions through independent high temperature, low temperature, and test zones. Compared to traditional single-chamber equipment, it reduces temperature change time and enhances testing efficiency.