Quick Water Quality Determination System

The rapid water quality analyzer works by using chemical reagents to react with specific substances in water, producing color changes, which are then measured by photoelectric sensors to convert absorbance into concentration. It is used for on-site detection of parameters such as residual chlorine, pH, ammonia nitrogen, and is suitable for daily monitoring in water treatment plants, sewage treatment facilities, and swimming pools.
Selection
Select the corresponding detection module based on the target indicators, considering whether the measurement range and detection limits meet the usage requirements. Verify the instrument certification standards, and ensure that the complexity of the operation process matches the personnel's skills. Compare the costs of reagents and consumables, as well as the maintenance cycles, across different models.

Terms

Instruments

Digestion determination does not affect the accuracy, equipped with PID automatic temperature control timing system, Optical inspection stability is less than 0.002A/20min, can store 30 standard Linear dispersion and 199 measurement values, IP65 protection design.

$ 1560.00

ED test technology integrates 8 specific absorption peak wavelengths, can detect more than 50 water quality items, supports user-defined 100 Measuring methods, with IP65 Protection Rating and 2000 sets of Data storage capabilities.

$ 1806.00

With 12 water quality paraMeter detection capabilities, resolution of 0.001mg/L, Repeatability 2%, micro-processing technology and long-life Illuminant, support custom Linear dispersion calibrating and data smoothing.

$ 1058.00

The eight-stage deep purification system ensures that the water quality is pure, the resistivity of the pRoduced water is 18.25MΩ .cm, and it is equipped with an intelligent Control system to realize automatic monitoring and a variety of water intake modes to meet the strict experimental requirements.

$ 4511.00

Measurement range 000-5.000 mg/L, single set of Reagent can complete 100 times detection, supporting the special Colorimetric tube operation is simple, suitable for rapid determination of urea content in water quality.

$ 164.00

With 18.2MΩ · cm ultra-pure water output and 10L/H water pRoduction capacity, 7-inch touch screen real-time display of water quality paraMeters, support for automatic circulation and consumables reminders, improve experimental efficiency and water quality Reliability.

$ 3491.00

Measurement range 0~ 1.5mg/L, resolution up to 0.01mg/L, eliminating human error, suitable for the determination of inorganic phosphoric acid content after digestion of various water samples.

$ 285.00

Equipped with 18.25MΩ · cm ultra-pure water quality and 100L/H water pRoduction capacity, 7-inch color touchscreen displays three-way water quality and temperature in real time, supports consumables failure reminder and automatic circulation system to ensure stable water quality.

$ 5195.00

It can simultaneously measure 7 water quality paraMeters, equipped with 45,000 data storage capacity, adopts IP67 waterproof grade and intelligent ElectRode identification system, supports automatic temperature compensation and fast Adjustment.

$ 2074.00

With 40L/H water pRoduction capacity and 18MΩ · cm resistivity ultrapure water output, the 7-inch touchscreen displays three-way water quality and temperature in real time, supports automatic circulation, consumables reminder and disinfection functions, ensuring stable water quality and low bacterial contamination.

$ 4408.00

Measurement range 0~ 500 ppm, accuracy +/- 3 ppm, support for CAL CheckTM Adjustment, suitable for a variety of water quality testing scenarios.

$ 215.00

With 40L/H water pRoduction capacity and 18.2MΩ · cm resistivity, 5.1-inch large screen real-time display of water quality, automatic circulation and disinfection system to extend the life of consumables, support regular quantitative water intake, all-plastic shell rust-proof and durable.

$ 2205.00

Support 16 water quality paraMeters synchronous testing, equipped with IP67/IP68 waterproof rating and automatic temperature compensation system, data storage capacity up to 45000 groups, Measurement range covers 0-400mS/cm conductivity and 0-1000FNU turbidity.

$ 8494.00

Digestion instrument and measuring instrument separation design to ensure measurement accuracy, using PID automatic temperature control technology, temperature range to 180 ℃, temperature control accuracy +/- 0.5 ℃, support 4 water sample batch processing, Optical inspection stability is better than 0.002A/20min.

$ 1753.00

Equipped with a 5.1-inch LCD screen to monitor water quality in real time, support three-way water quality and temperature display, automatically cycle to prolong the life of consumables, set the use time of consumables and remind, and one-click disinfection function to reduce bacterial contamination.

$ 1498.00

Articles

Wavelength selection for the determination of sulfate content in water quality using photometric titrator
This article discusses how to select the wavelength when using a photometric titrator to determine the sulfate content in water. The core issue lies in the fact that wavelength selection directly affects the accuracy and anti-interference capability of the detection.
Conductivity meter measures the conductivity of water extract from pulp.
This article introduces the method of measuring the electrical conductivity of pulp water extracts using a conductivity meter. Electrical conductivity reflects the content of soluble ions in pulp, which is used to evaluate washing effectiveness and the impact of water quality.
Practical Application of Spectrophotometer in COD, Ammonia Nitrogen, and Total Phosphorus Determination
This article introduces the practical applications of spectrophotometers in measuring key water quality indicators—Chemical Oxygen Demand (COD), Ammonia Nitrogen, and Total Phosphorus.
How to Choose a Suitable Multi-Parameter Water Quality Analyzer Based on Detection Indicators
When selecting a multi-parameter water quality analyzer, the first step is to clarify the parameters that need to be measured, such as physical, chemical, or biological indicators, because different parameters require different detection principles, measurement ranges, and accuracy levels for the instrument.
How to choose between laboratory benchtop and portable water quality testing instruments
When selecting a water quality analyzer, the primary consideration is whether the testing task is conducted in a laboratory or on-site. Benchtop analyzers are suitable for laboratories, offering high precision, excellent stability, and the ability to handle large sample volumes. Portable analyzers are designed for fieldwork or emergencies, emphasizing rapid results, ease of operation, and strong environmental adaptability.
How can multi-parameter water quality analyzers avoid cross-contamination and improve data accuracy?
This article mainly discusses how to avoid cross-contamination in multi-parameter water quality testing to ensure data accuracy. Cross-contamination refers to the residue from a previous sample affecting the results of the next sample, which may lead to data deviation.
Which is more convenient for water hardness testing: the electrode method or the titration method?
Both electrode method and titration are used to measure water hardness. The choice depends on specific needs: opt for the electrode method for speed, and choose titration for accuracy.
Application of UV-Visible Spectrophotometer in the Detection of Heavy Metals in Water
This article introduces the application of ultraviolet-visible spectrophotometry in the detection of heavy metals in water.