Imported Humidity Sensor and Compressor, temperature control accuracy of +/- 0.5 ℃, humidity deviation +/- 3% RH, equipped with independent temperature limit alarm system and test hole to ensure the safety and reliability of the experiment.
Temperature range -40~ 100 ℃, humidity control 35~ 95% RH, fluorine-free design, imported stainless steel liner, support multi-stage programming and remote communication, ensure uniform and stable insulation Humidity.
Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, temperature control accuracy +/- 0.1 ℃, equipped with independent temperature limit alarm and double-decked Glass window to ensure safe and stable operation of the experiment.
Adopt ALLCOLD ™ equilibrate refrigeration and automatic defrosting, Temperature range 0~ 65 ℃, humidity deviation +/- 2%, equipped with PT100 Sensor and adjustable wind speed, support continuous operation and remote monitoring.
Using French Taikang Compressor and multi-wing air supply circulation, Temperature Uniformity ≤ +/- 2 ℃, humidity deviation + 2-3% R.H, with independent temperature limit alarm and double-decked Glass observation window to ensure safe and reliable testing.
Adopt equilibrate control method, temperature control accuracy +/- 1.0 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system, the box with test hole is easy to operate, to ensure the safety and reliability of the experiment.
Mirror stainless steel liner and high-efficiency air circulation system, Temperature range -5~ 80 ℃, Humidity deviation +/- 3% R.H., support 99 cycle programs to ensure experimental Stability and uniformity.
Adopt equilibrated refrigeration technology, with small temperature fluctuations, equipped with automatic defrosting function; fluorine-free R134 refrigerant is more energy-saving and environmentally friendly; mirror stainless steel liner, adjustable shelf; microcomputer PID control, Humidity Accuracy +/- 0.1 ℃.
Microcomputer temperature and humidity controller, Temperature Fluctuation +/- 0.5 ℃, humidity fluctuation +/- 5% RH, with over-temperature protection, independent temperature limit alarm system to ensure safe and stable operation of the experiment.
Adopt mirror stainless steel liner and PID Control mode, Temperature range 0~ 60 ℃, Humidity deviation +/- 5~ 8% R.H., 99 cycle programs and independent temperature limit alarm system.
Humidity Control Range 80~ 95% RH, Temperature resolution 0.1 ℃, Humidity deviation +/- 3% RH, Mirror stainless steel liner easy to clean, independent temperature limit alarm system to ensure safety.
Sensor imported, temperature control accuracy of +/- 0.5 ℃, Humidity deviation of +/- 3% RH, equipped with independent temperature limit alarm system and test hole, to ensure safe and stable operation of the experiment.
The mirror stainless steel liner is easy to clean, the TMHM equilibrating conditioning method controls temperature and humidity accurately, Temperature Fluctuation +/- 0.5 ℃, Humidity deviation +/- 3% RH, with independent temperature limit alarm system.
Temperature range 15~ 45 ℃, Humidity control 60~ 85% R.H., with independent temperature limit alarm and optional test hole, to ensure the safety and convenient operation of the experiment.
Adopt multi-stage programmable PID controller and TMHM equilibrate Conditioning method, temperature control fluctuation high temperature +/- 0.5 ℃, humidity control deviation +/- 3% RH, with independent temperature limit alarm and 100 group program storage function.