Dial-Type Thickness Gauge

The dial thickness gauge measures the thickness of objects through mechanical contact. The probe contacts the sample, driving the gears to rotate, and the pointer displays the value on the dial. It is used to measure the thickness of materials such as coatings, films, and sheets, ensuring production meets specification requirements.
Selection
When selecting, consider that the measurement range covers the sample thickness, the precision meets the detection requirements, the probe size fits the shape of the object being measured, the material is corrosion-resistant to suit the environment, and regular calibration maintains measurement accuracy.

Terms

Instruments

Measurement range 0-10mm, accuracy ≤ 0.02mm, using Dial reading, Graduation 0.01mm, upper probe diaMeter 6mm plane, suitable for workshop site and laboratory thickness measurement.

$ 219.00

Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.

$ 88.00

Battery-free, durable rare earth cobalt magnets, Measurement range 0 to 200 μm, accuracy +/- 1 µm (within 20 µm), with audible cues and wear-resistant carbide Probe.

$ 464.00

Dial indicator reading is accurate, with dual unit display without conversion, maximum Measured value 100N, Indication Error +/- 1%, can freely switch peak holding and real-time load value, suitable for all kinds of fixture installation.

$ 136.00

Dial indication for easy reading, with dual unit display function without conversion, can freely switch peak holding and real-time value mode, Measurement accuracy of +/- 1%, push-pull Rod Travel 10mm, suitable for all kinds of fixture installation.

$ 136.00

Dial indicator reading accuracy, with peak holding and real-time load measurement switching function, the maximum Measured value 30kg, Indication Error +/- 1%, compact and portable and easy to operate.

$ 136.00

Measurement range 0-20mm, accuracy ≤ 0.02mm, probe diaMeter Φ 6mm, Dial reading indexing value 0.01mm, pressure 22kPa +/- 5kPa, in line with chemical industry standards.

$ 307.00

Measurement range 0~ 10mm, accuracy ≤ 0.02mm, probe center to the maximum measurement depth 130mm, Dial reading, portable handheld design, suitable for on-site rapid detection.

$ 261.00

Measurement range 0-10mm, accuracy ≤ 0.02mm, Graduation 0.001mm, probe diaMeter Φ 20mm plane, portable handheld design, in line with chemical industry standards.

$ 361.00

Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.

$ 180.00

Dial design can maintain the maximum Measured value display, Measurement range 0-100 Shore, accuracy up to 1shore, made of wear and corrosion resistant stainless steel aluminum oxide material.

$ 1053.00

Measurement range 0-1mm, Graduation 0.001mm, using Dial reading, probe diaMeter Φ 5mm plane, pressure 22kPa +/- 5kPa, simple and reliable structure, suitable for laboratory and field determination.

$ 267.00

Small portable size only 225mm * 60mm * 51mm, Dial reading accuracy +/- 1%, with peak holding and real-time load switching function, support dual unit display without conversion, push-pull Rod Travel 10mm.

$ 136.00

Measurement range 0-20mm, accuracy ≤ 0.02mm, Graduation 0.01mm, probe diaMeter Φ 56.42mm plane, in line with HG/T 2041-2009 standard, easy to operate.

$ 477.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Articles