Computerized Color Comparison Meter

A computer colorimeter illuminates the sample with a light source, and the sensor captures the reflected light, decomposing the color into digital signals. These signals are then compared with standard colors to assess differences. It is used to measure color consistency in products such as coatings and plastics, ensuring color matching between production batches.

Instruments

In line with the LOVIBOND color scale standard, the sub-field of view Color matching Sensitivity is high, the Measurement range is red 0.1-79, yellow 0.1-79 LOVIBOND units, and the structure is simple and easy to operate.

$ 599.00

Matte design system Color, including 290 commonly used Colors, 5 color samples per page 3.1x5.0cm, convenient for industry color comparison and application reference.

$ 93.00

Featuring a 3.5-inch touchscreen for easy operation, it offers a measurement accuracy of 0.01 and a repeatability of ΔE*ab ≤ 0.03. Equipped with multiple built-in color cards for fast matching, it supports various color difference formulas and cloud-based data sharing.

$ 231.00

Automatically collect viscosity data and generate flow Linear dispersion, support ten historical data comparison analysis, measurement results can be exported to Excel format file, easy data processing and archiving.

$ 349.00

Adopt internationally recognized LOVIBOND color scale, measurement range red 0.1-79, yellow 0.1-79, blue 0.1-49 LOVIBOND units, minimum indication 0.1, equipped with three specifications Cuvette to meet multi-sample testing needs.

$ 677.00

Featuring a 45°/0° illumination method and full-spectrum LED light source, it has an 8mm measurement aperture with a standard deviation ΔE*ab of less than 0.03, ensuring excellent repeatability. The built-in compensation optical path ensures data stability, eliminating the need for frequent calibration. Compact and portable, its size is comparable to that of a lipstick.

$ 130.00

Contains 216 Classic Colors, semi-matte surface, full page color sample size 5.0x15.0cm, monochrome design for easy comparison, with U-shaped protective cover for loss prevention.

$ 145.00

Adopting a double-sided design, the front supports No. 4 Cup and No. 2 Zahn Cup conversion, and the back supports ISO3-6, No. 3 Zahn Cup and Gardner Viscometer conversion, covering ISO2431, ASTM D4212 and other standards.

$ 256.00

Colourless Glass material, inner diaMeter accuracy of +/- 0.05mm, height tolerance of +/- 1mm, to ensure the accuracy of Color Comparison and Experimental Repeatability.

$ 119.00

With CRI = 98 high color rendering index and 6500K color temperature, lamp with Timer, all-metal structure, large folio size for easy operation, can be hung and installed to ensure accurate Color comparison.

$ 719.00

Compliant with ISO 8502-3 standard, equipped with illuminated magnifying glass and dust comparison display panel, can accurately assess the size and distribution of surface dust, support pass test and long-term recording.

$ 367.00

In line with ISO3664 international standards, color rendering index of 98, support multi-light source switching, all-metal structure to ensure stability and durability, inclined table in line with visual observation habits.

$ 1913.00

Equipment provides a variety of standard illuminant options, maximum support three Illuminant, high CRI = 98, with Illuminant Timer, uniform lighting, easy to operate, suitable for Color Comparison.

$ 848.00

High Accuracy ball screw drive, fully computerized data collection system, 0.5 level force measurement accuracy and 1/300000 force value resolution, support three closed loop control and custom test method.

$ 3946.00

Using LOVIBOND color scale measurement, Measurement range Red 0.1~ 79.9, Yellow 0.1~ 79.9, Blue 0.1~ 49.9 LOVIBOND units, equipped with a variety of Cuvette sizes and 1.9 times magnifying glass.

$ 732.00

Articles

The necessity of a standard light source box in visual color comparison and color difference assessment of coatings.
In the production of coatings, accurate color evaluation is crucial. Visual color comparison is easily affected by light, as natural light is unstable, and different lighting conditions can make colors appear different.
Visual color comparison method using colorimetric tubes to determine the color phase of varnish.
Colorimetric tube visual colorimetry is a method used to determine the color hue tendency of varnish samples by directly comparing them with a standard color scale using the human eye. During operation, samples and standard liquid columns should be prepared using colorimetric tubes of consistent specifications under standard lighting conditions, and the hue differences should be observed in parallel.
Operating Specifications for the Determination of Hexavalent Chromium Content in Wastewater Using Colorimetric Titration Apparatus
This article introduces the standard operating procedure for determining hexavalent chromium content in wastewater using a colorimetric titrator. The method is based on the reaction between hexavalent chromium and diphenylcarbazide under acidic conditions to form a purplish-red complex, with the titration endpoint determined by monitoring changes in absorbance at a wavelength of 540 nanometers.
Standardized ink color evaluation environment for visual color comparison cabinets
This article introduces the standardized application of visual color comparison boxes in ink color evaluation. It emphasizes that to ensure the accuracy and consistency of color judgments, the evaluation environment must be strictly controlled.
Application of Colorimeter and Color Matching Box in Pigment Color Inspection
A colorimeter and a light booth are two primary tools in pigment color inspection. The colorimeter measures color through photoelectric principles, while the light booth provides a standardized light source environment for visual evaluation of color effects, metamerism, and other phenomena.
Comparative Study of Lovibond Colorimeter and Iron-Cobalt Colorimeter
The Lovibond colorimeter and the iron-cobalt colorimeter are two widely used visual color measurement instruments in the industrial field. Both are designed based on the principle of standard color comparison, yet they exhibit significant differences in their specific implementation methods and application standards.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.