Constant Temperature Heating Tank

The constant temperature heating bath maintains the liquid inside the bath at a set temperature through electric heating elements and a temperature controller. It is used for laboratory operations such as constant-temperature heating of samples and reaction insulation. It is commonly found in applications requiring a stable temperature environment, such as material aging tests and viscosity measurements.
Selection
When selecting, consider the temperature range and accuracy, corrosion resistance of the tank material, compatibility of capacity with sample size, and uniformity of the stirring function, as well as the completeness of safety protection features. Determine the temperature control method and heating power based on practical applications, and pay attention to the tank opening size and operational convenience.

Terms

Standards

Instruments

With dual functions of refrigeration and heating, Temperature range -20~ 100 ℃, Temperature Fluctuation +/- 0.2 ℃, support multi-stage programming and internal and external circulation, equipped with over-temperature alarm and liquid level protection.

$ 1648.00

Temperature range -5~ 95 ℃, accuracy +/- 0.05 ℃, Tank volume 15L, pump flow 6L/min, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 1505.00

Temperature range -40~ 95 ℃, temperature accuracy +/- 0.1 ℃, Tank volume 15L, providing uniform and constant temperature field source, suitable for a variety of test needs.

$ 2936.00

Using 300mm × 300mm stainless steel inner Tank, equipped with heating temperature control function, support timing operation and drawer sample stage, to ensure safe and efficient cleaning process.

$ 9433.00

Water Bath, water temperature box and boiling disinfection box three functions, Temperature range from room temperature to 100 ℃, Tank size 42 * 18 * 20cm, to meet a variety of experimental heating and disinfection needs.

$ 180.00

With three uses of water Bath, thermostatic and boiling disinfection, Temperature range RT +~ 100 ℃, Tank volume 36L, suitable for a variety of experimental heating and equipment processing needs.

$ 209.00

The use of domestic circulation to ensure uniform and constant temperature, external circulation pump can lead the liquid outside the Tank heating, temperature control accuracy +/- 0.1 ℃, Temperature Fluctuation +/- 1 ℃, LED dual window digital display, insulation layer efficient, Benchtop structure small size.

$ 1080.00

Temperature range -10~ 100 ℃, Temperature Stability +/- 0.02 ℃, using imported Compressor and SUS304 stainless steel heating device, support internal and external circulation, can accommodate 500ml beaker directly inserted into use.

$ 1361.00

Temperature control accuracy of +/- 0.1 ℃, Tank volume 6.7L, equipped with over-temperature alarm and liquid level protection system, support multi-stage programmable operation, circulating pump Flow rate 8L/min, to meet the needs of complex experiments.

$ 562.00

Temperature range covers -30~ 100 ℃, temperature control accuracy of +/- 0.02 ℃, with over-temperature low temperature sound and light alarm and liquid level protection functions, support internal and external circulation and data processing interface.

$ 1756.00

Temperature Fluctuation +/- 0.2 ℃, Temperature range 5~ 150 ℃, supports multi-stage programmable control, with over-temperature alarm and liquid level protection functions, circulating pump Flow rate up to 8L/min.

$ 927.00

Temperature range -40~ 95 ℃, temperature control accuracy +/- 0.1 ℃, Tank volume 7.5L, circulating pump flow 6L/min, providing a uniform and constant temperature environment.

$ 2089.00

Temperature range -20~ 100 ℃, temperature control accuracy +/- 0.02 ℃, equipped with imported Compressor and circulation pump, support internal and external circulation, with over-temperature alarm and liquid level protection functions to ensure the safety and reliability of the sample.

$ 1460.00

Temperature control accuracy of +/- 0.02 ℃, Temperature range -40~ 100 ℃, with over-temperature alarm and liquid level protection function, support internal and external circulation and data processing interface, to ensure experimental safety and data integrity.

$ 2052.00

Temperature range -10~ 100 ℃, temperature control accuracy +/- 0.2 ℃, support multi-stage programming and internal and external circulation, provide over-temperature and low temperature sound and light alarm and liquid level protection.

$ 1450.00

Articles

Constant temperature bath selection: circulation method and temperature control range.
This article on thermostatic bath selection primarily analyzes two core factors: circulation mode and temperature control range. The circulation mode is divided into natural convection and forced circulation, where the former is suitable for simple static experiments, while the latter offers higher precision and is better suited for multiple samples or integration with external devices.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
How to Match the Selection of Fineness Gauge with Grinding Process Requirements
The fineness gauge is used to measure the particle dispersion of materials such as slurries and coatings, reflecting the particle size distribution through the depth of grooves on its surface.
Operating Specifications and Result Interpretation of Paint Fineness Gauges
The fineness gauge is used to measure the dispersion of particles in paint. During operation, the sample should be applied to the groove under standard conditions, and a scraper is used to spread it evenly to form a wet film. The particle visibility is then observed under appropriate lighting, and the fineness value is read from the corresponding scale.
Scraper Fineness Gauge for Determining the Fineness of Paste Inks
The Scraper Fineness Gauge is used to measure the dispersion degree of pigment particles in products such as paste inks. Its principle involves scraping a film on a scraper plate with wedge-shaped grooves and observing the scale at which particles appear to assess the fineness, with the result expressed in micrometers.
Application of Gardner Colorimeter in the Determination of Oil and Fat Color
The Lovibond tintometer determines the color of oils and fats by visually comparing them with standard glass color standards, with results expressed as numerical codes. During operation, clarified oil samples are poured into the colorimetric cell and compared with color chips under a stable light source.
The difference between a wire bar coater and a gap-type wet film applicator.
The wire-wound drawdown bar directly quantifies the coating through the gap between wires, making it suitable for thin coating preparation with high precision, particularly for low-viscosity fluids. In contrast, the gap-type wet film applicator indirectly controls film thickness through the groove depth, with the actual coating thickness significantly influenced by material properties, making it more suitable for high-viscosity coatings and thick film preparation.
The difference between a wire-wound rod coater and an extrusion coating rod
This article primarily compares the technical differences between wire-wound and extrusion coating rods. Although they are interchangeable in most scenarios, there are subtle variations in liquid loading capacity due to their distinct groove principles.