Static Humidity and Heat Test Chamber

The static damp heat test chamber generates saturated steam by heating a water tank, maintaining a constant temperature and humidity environment within a sealed space. It is used to simulate the weathering resistance of products under humid climatic conditions and is commonly employed for verifying the moisture-proof performance of electronic components and paint samples.
Selection
When selecting, focus on the corrosion resistance of the inner tank material, ensure that the temperature and humidity control accuracy meets the testing standards, and leave ventilation gaps based on the sample dimensions. Confirm that the equipment is designed to prevent condensation, and ensure that the compressor and sensors are suitable for long-term continuous operation.

Terms

Standards

Instruments

Adopt equilibrating Conditioning Control system, Temperature range -20~ 150 ℃, humidity control 20~ 98% RH, equipped with imported Compressor and multi-stage PID calculation, ensure uniform and stable heat preservation Humidity, energy saving and high efficiency.

$ 2457.00

Temperature range -10~ 100 ℃, humidity control 35~ 95% RH, with independent temperature limit alarm system and multi-stage programmable PID controller to ensure safe operation and precise control of temperature and Humidity.

$ 3078.00

Adopt 7.0 inch Touchscreen controller, support 100 programs and 1000 cycles; high temperature and humidity control accuracy, temperature fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier and French Taikang Compressor to ensure stable and reliable testing.

$ 7222.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -60~ 150 ℃, humidity control 30~ 98% RH, multi-wing air supply circulation and independent refrigeration system, uniform temperature and humidity distribution, low failure rate.

$ 13209.00

Inner Chamber dimensions 800 * 1000 * 1000mm, temperature range -20~ 150 ℃, humidity range 30~ 98% R.H., using French Taikang Compressor and multi-wing air supply circulation, uniform temperature and humidity distribution, high control accuracy.

$ 9191.00

Temperature range -10~ 100 ℃, Temperature resolution 0.1 ℃, using programmable PID controller and TMHM equilibrating Conditioning method, temperature and humidity control accurate fluctuation is small, with independent temperature limit alarm system and a variety of Safety protection functions.

$ 7871.00

Inner Chamber dimensions 800 * 1000 * 1000mm, Temperature range -40~ 150 ℃, humidity control 30~ 98% RH, using French Taikang Compressor and multi-wing air supply circulation system to ensure uniform and stable distribution of temperature and humidity.

$ 12531.00

Adopt multi-stage programmable PID controller to achieve accurate temperature and Humidity control, with small fluctuations; unique air duct circulation system to ensure uniform temperature and Humidity; with 100 sets of programs and 1000 segments capacity, support RS-232 or RS-485 communication interface, easy data monitoring and remote operation.

$ 9152.00

Adopt TMHM equilibrate Conditioning method, temperature fluctuation +/- 1.0 ℃, humidity deviation +/- 3% RH; with 100 sets of program capacity and P.I.D automatic calculation function, ensure stable and uniform heat preservation Humidity, support multi-stage programmable operation.

$ 2841.00

Using 7.0 inch Touchscreen controller, high temperature and humidity control accuracy, Fluctuation ≤ +/- 0.5 ℃, humidity deviation + 2, -3% R.H; built-in stainless steel humidifier, multi-wing air supply circulation, uniform temperature and humidity distribution, improve test reliability.

$ 6560.00

The equilibrate temperature control method is used to achieve Temperature Fluctuation ≤ +/- 0.5 ° C, humidity control range is 30-98% RH, equipped with a large area observation window to observe the sample status in real time, and the studio is made of 304 stainless steel.

$ 5705.00

Adopt equilibrate Conditioning Control system, Temperature Humidity range -60~ 150 ℃, 20~ 98% RH, Equipped with imported Compressor and environmentally friendly refrigerant, High Accuracy and stable operation. Special air circulation design ensures uniformity, built-in multiple protection functions, prolong equipment life.

$ 3640.00

Temperature range -20~ 100 ℃, Humidity deviation +/- 3% R. H, using all fluorine-free environmental protection design, multi-stage programmable PID controller to ensure accurate and stable insulation Humidity control, with independent temperature limit alarm system to ensure safety.

$ 6194.00

Adopt fluorine-free environmental protection design, Humidity Control Range 35-95% RH, input Power 2300W, with PID automatic calculation function, ensure accurate and stable thermal insulation Humidity control, equipped with multiple Safety protection systems.

$ 5405.00

Using French Taikang fully enclosed Compressor, Temperature Fluctuation ≤ +/- 0.5 ℃, Humidity deviation + 2, -3% RH, with 100 sets of program capacity and RS-232/485 communication interface, improve test accuracy and convenience.

$ 10804.00

Articles

Comparison of Rotational Viscometer and Capillary Rheometer in Testing the Flowability of Resin Processing
The rotational viscometer measures torque via rotor rotation, making it suitable for testing the static or low-shear fluidity of resins under low shear rates, with simple and quick operation. The capillary rheometer, on the other hand, forces samples through a capillary to simulate high-shear processing, providing flow data closer to actual production conditions, but it is more complex and time-consuming to operate.
Humidity and heat test chamber tests the moisture absorption rate of resin under high temperature and high humidity conditions.
This article introduces the method of using a hygrothermal test chamber to measure the moisture absorption rate of resin under high temperature and high humidity conditions.
Humidity and Heat Test Chamber for Evaluating Coating Performance under High Temperature and High Humidity Conditions
This article introduces how a humidity and heat test chamber is used to evaluate the performance of coatings in high-temperature and high-humidity environments. Coatings are widely used in industries such as automotive and electronics, but they are prone to issues like reduced adhesion and blistering under actual high-temperature and high-humidity conditions.
Determination of Static Surface Tension of Color Coatings Using the Platinum Plate Method with a Surface Tensiometer
This article introduces the method of measuring the static surface tension of colored paints using the platinum plate method. It explains the principle, which involves calculating the surface tension by measuring the force when the platinum plate is lifted from the liquid surface.
Correlation Analysis between Puncture Strength and Bursting Strength of Paperboard
This article analyzes the correlation between the puncture strength and burst strength of cardboard. The two properties respectively measure the ability of cardboard to resist dynamic impact and static pressure. Although their testing principles differ, both are closely related to factors such as the fiber structure and lamination process of the cardboard.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.