Metal color wheel

The metal drawdown bar evenly applies coatings onto the substrate surface by rotating a metal disc, forming a wet film of standard thickness for visual color comparison or instrumental measurement of properties such as color and hiding power. It is suitable for quality control and research and development testing in the coatings and inks industries.
Selection
When selecting, consider that the wheel material must be corrosion-resistant, the groove specifications should match the viscosity of the sample to be tested, and the rotation mechanism should be stable and free from shaking. Determine the number and size combination of grooves according to the testing standards, while also considering substrate compatibility and cleaning convenience.

Terms

Standards

Instruments

With high color strength index CRI = 98 and all-metal material, equipped with D65 and D50 dual light sources, it can simulate different lighting conditions, provide uniform lighting and stable structure to ensure accurate and reliable color evaluation.

$ 1848.00

With a high CRI of 98 and a color temperature of 6500K, it is equipped with a light source Timer and three drawer, and the all-metal construction ensures durability and ease of operation.

$ 2171.00

With three light sources including D65, TL84 and D50, high color strength index CRI = 98, the all-metal material is stable in structure, providing uniform lighting and accurate color evaluation, suitable for a variety of industry environments.

$ 1961.00

Using high color rendering index CRI = 98 D65 light source, equipped with 4 36W lamps and light source Timer, all-metal structure to ensure stable and uniform light, in line with ISO3664 international standards.

$ 1735.00

High definition color screen display rich information, all metal shell anti-interference; viscosity range 400~ 80000000mPa · s, support timing function to ensure data conformity, high-speed processor to improve efficiency.

$ 2252.00

High definition color screen display rich information, all metal shell anti-interference; viscosity range 10~ 16000000mPa · s, speed 0.1~ 200rpm; support timing measurement and data storage to ensure conformity.

$ 2252.00

Adopt 2.4 inch full view color screen and 0.1Gs resolution, support single and continuous Measurement mode, built-in 3000mAh lithium battery for long battery life, metal base design to improve durability, suitable for high-gloss material detection.

$ 393.00

Adopt high definition color screen and metal shell, strong anti-interference; support 0.1~ 200rpm continuously variable speed and +/- 1% Measurement accuracy; with timing function and real-time viscosity Linear dispersion, suitable for non-newtonian fluid testing.

$ 2010.00

Using high definition color screen and metal shell design, strong anti-interference. Equipped with high-speed processor and timing function, Measurement accuracy +/- 1% F.S., support real-time viscosity Linear dispersion display and data storage.

$ 2171.00

All-metal material structure is sturdy and durable, equipped with swirl/spin reflection plate and roller foot for easy adjustment and movement; Graphica imported lamp, color rendering index CRI ≥ 95, reflection and transmission of each 4 36W lamp to ensure uniform lighting.

$ 1187.00

It adopts all-metal sheet metal structure, equipped with 4 18W high color rendering lamps, with a color rendering index of more than 95, with Illuminant Timing function, and the inclined operation table conforms to human visual observation habits.

$ 1074.00

The all-metal sheet metal structure is sturdy and stable, equipped with 36W × 4 Graphica imported lamps, CRI ≥ 95, with Illuminant Timer, inclined platform conforms to visual observation habits, and the foot with roller can be moved and adjusted.

$ 961.00

High definition color screen displays rich information, all metal shell enhances anti-interference, PT100 temperature sensor ensures accuracy, Measurement range 320~ 320000000mPa · s, supports continuously variable speed and automatic timing function, suitable for non-newtonian fluid analysis.

$ 1445.00

The all-metal sheet metal structure is sturdy and stable, equipped with 36W × 4 Graphica imported lamps, with a color rendering index CRI ≥ 95, uniform lighting and Illuminant Timer, and the inclined surface console conforms to visual observation habits.

$ 1639.00

Adopt all-metal sheet metal bracket structure, equipped with 36W × 4 reflection lamps and 36W × 4 transmission lamps, color rendering index CRI ≥ 95, tempered Glass and acrylic uniform plate make the light uniform and not dazzling, with rollers and adjustable support feet.

$ 1639.00

Articles

How to choose a single-column electronic universal testing machine based on the maximum test force
This article introduces how to select a single-column electronic universal testing machine based on the maximum test force. First, determine the strength range according to the material type and standard, such as plastics, metals, etc. Then, calculate the maximum force based on the tensile strength and specimen area, and multiply it by a safety factor of 1.3 to 1.5.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
Cup Test Instrument for Coating Tests the Impact and Deformation Resistance of Coatings on Metal Substrates.
This article introduces how the coating cupping tester measures the resistance to stamping deformation of coatings on metal substrates.
T-bend tester for coatings is used to determine the T-bend grade of metal sheet coatings.
This article introduces how the T-bend tester for paint films is used to evaluate the flexibility and adhesion of coatings on metal sheet surfaces.
Brinell hardness tester is used for hardness testing of plastics and soft metal coatings.
This article introduces how a Brinell hardness tester is used to measure the hardness of plastics and soft metal coatings.
Atomic Absorption Spectrometer for Measuring Heavy Metal Content in Rubber
This article introduces a method for determining the heavy metal content in rubber using atomic absorption spectrometry. It first explains that rubber may contain harmful elements such as lead and cadmium, which require accurate measurement.
Controllable Coating of Composite Separator Coatings for Lithium Metal Batteries
This article primarily explores the controllable coating technology for composite separator coatings in lithium metal batteries.
Preparation of metal thin films by the coating method for mechanical property studies.
This paper discusses the key process parameters in the preparation of metal thin films using a film coater and their effects on mechanical properties. The film coater forms metal thin films on a substrate through solution deposition, with its uniformity and repeatability directly influencing film quality.
Application of Coating Thickness Gauges in Electroplating Thickness Detection
Coating thickness gauges are used to measure the thickness of electroplated layers, primarily employing the electromagnetic induction method for measuring non-magnetic coatings on magnetic substrates, or the eddy current method for measuring insulating coatings on non-magnetic metal substrates.
Eddy current thickness gauge measures metal coatings on non-conductive substrates.
The eddy current thickness gauge utilizes the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil to induce eddy currents in the metal coating, thereby measuring thickness based on changes in coil impedance.
Use of Muffle Furnace for Ash Determination in Pulp Inorganic Matter Testing
This article introduces the application of the ash determination muffle furnace in the detection of inorganic substances in pulp. The muffle furnace removes organic matter in the sample through high-temperature combustion, and the remaining inorganic residue, known as ash, is used to analyze the content of fillers and metal ions in the pulp.
Coulometric Method Coating Thickness Gauge for Non-Destructive Measurement of Precious Metal Coatings
The coulometric coating thickness gauge measures the thickness by calculating the amount of electricity required to dissolve the precious metal coating through the principle of electrolytic dissolution. This method is non-destructive to the overall sample, only forming tiny electrolytic spots.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Eddy current thickness gauge detects coatings on non-ferrous metals.
The eddy current thickness gauge operates on the principle of electromagnetic induction, generating an alternating magnetic field through the probe coil, which induces eddy currents on the surface of non-ferrous metal substrates.
Atomic Absorption Spectrometer for Determining Heavy Metal Content in Coatings
This article introduces a method for determining the content of heavy metals such as lead, cadmium, chromium, and mercury in coatings using atomic absorption spectroscopy. The method is based on the absorption of characteristic wavelength light by atoms for quantification. It requires acid digestion pretreatment of coating samples and optimization of instrument conditions to improve accuracy.