Digital display design, compact and easy to operate, Measuring accuracy, low power consumption, easy to carry, suitable for field and laboratory rapid Hardness detection.
Suitable for low Hardness Rubber and Sponge Determination, Measurement range 20-90HAO, Indication Error ≤ +/- 1HAO, Portable design for quick field testing.
Suitable for low hardness rubber and sponge determination, measurement range 20-90HAO, resolution 0.1HAO, support real-time mode, peak mode, automatic timing and average mode.
Travel range of pressure needle 0~ 2.5mm, measurement error +/- 1HAO, suitable for low Hardness rubber and sponge materials, can be hand-held or installed on a fixed load measuring rack.
Travel range of the crimp is 0~ 2.5mm, measurement error is +/- 1HAO, and the end pressure of the crimp is 0.55~ 8.05N, which is suitable for accurate Hardness detection of low Hardness rubber materials.
Adopt double-pointer design, pressure needle Travel 0~ 2.5mm, measurement error +/- 1HAO, can be handheld or used with the bench, suitable for stable and fast detection of low Hardness rubber materials.
Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
Measurement range 0~ 100HC, error +/- 1HC, suitable for the detection of microporous materials with stress above 0.049MPa when the compression rate is 50%.
Che type hardness Gauge, test range 0~ 100HBa, equivalent to brinell hardness 25~ 150HB, no support, one-handed operation, with MAX Maximum retention function, suitable for various aluminum alloys and frp materials.
The device adopts D-type Impact device, supports 360 ° measurement, can display a variety of Hardness standards, has 600 sets of Data storage capacity, is small in size and weighs only 0.2kg, and has a standby time of 100 hours. It is suitable for small spaces and field environments.
Supporting D-type Shore DuroMeter, applying 5kg test force by weight, equipped with Glass bench and adjusting nut to ensure full contact with the sample and improve measurement Stability.
Suitable for materials such as high Hardness rubber and engineering plastics, pressing needle Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, in line with ASTM D 2240-05 and GB/T2411-2008 standards.
The C-type Impact device has a small impact force and is suitable for surface hardening and thin-walled component testing; dual coil technology ensures +/- 6HL typical accuracy; built-in directional Sensor automatically compensates for errors; supports 5 Hardness standard conversions.
Suitable for medium Hardness rubber, thermal plasticity resilience and other materials, Measurement range 0-100HB, can be hand-held or matched with a fixed load test bench to ensure stable measurement.
Suitable for soft rubber, thermal plasticity resilience and extremely soft plastics, Hardness Measurement range < 20 HDO, with real-time, peak, timing and average Measurement mode, can be connected to the computer for data management and analysis.