The sampling area is 100mm ² and the error is controlled within +/- 0.35cm ², which can handle 0.1~ 1.2mm Film thickness materials. The circular sampling design is used to ensure the standard of the sample, and the operation is simple and the results are reliable.
The special No. 10 steel knife edge is used to ensure durability, the punching sample is smooth without burrs, the integrated casting structure is sturdy and not deformed, the sampling area is 100cm2, and the sampling Film thickness range is 0.01-1 mm.
Cutting sample area of 100cm ², accuracy +/- 0.35, suitable for paper single or multi-layer 0.1-5 mm and ordinary Cardboard single layer < 6mm thickness, compact structure and labor-saving operation.
Special No. 10 steel high temperature quenching knife edge, smooth cutting without burrs; one-piece casting structure is sturdy and durable; sampling area 100cm ², error +/- 0.35cm ², suitable for 0.1~ 1.2mm Film thickness material.
Synchronized processing of 12-bit samples, temperature control accuracy of +/- 1 ℃, circular water Bath heating and independent air path adjustment. Each air needle channel can be switched on and off separately, 316 stainless steel material is corrosion resistant, suitable for a variety of testtube specifications, supports timing and over-temperature alarm functions.
The precision blade combination ensures that the edge of the specimen is flat, and 152 * 12.7mm annular compression specimens and (200~ 250) * 15mm tensile specimens can be cut, meeting TAPPI-T409 and JIS-P8113 standards.
Using electric pressure system and circular pressing operation mode, printing pressure 0-4mm, speed 0-100 Meters, adjustable scraper pressure and speed, support low accuracy overprinting and Color detection.
The precision blade combination ensures that the edge of the sample is flat, and can cut 152 × 12.7mm annular pressure samples and (200~ 250) × 15mm tensile samples, with a volume of 670 × 450 × 470mm and a weight of 35kg.
Fillable internal reference solution design with circular Glass sensitive membrane and annular ceramic liquid junction for low Conductivity Detector samples ensures measurement Stability and accuracy.
Using irreversible discoloration technology, white turns black after overheating while displaying numbers, Measuring temperature 75 ° C, circular patch design is easy to observe temperature changes.
The adhesion was measured by the circular trace method, the drawing diaMeter was 0~ 10.5mm, and the Working Travel ≥ 80mm. The integrity of the paint film was evaluated by seven grades, and the operation was simple and conformed to the GB/T1720 standard.
Can cut 25 * 100mm sample, sampling error +/- 0.5mm, sampling thickness range of 18mm, fast and accurate completion of Corrugated Board Edge Crush Test and adhesive strength test sample preparation.
Pressure sensitive adhesive paste firmly, 65 ℃ single point temperature measurement accuracy, irreversible discoloration characteristics can permanently record the overtemperature state, circular design for easy observation, 2x2cm specification suitable for small space installation.
Precision combination of cutting edge to ensure that the sample edge flat, especially for ring pressure test design, can cut standard samples, easy to operate, cutting effect is good.
The circular stainless steel liner is used to prevent condensation and dripping, the copper tube bell mouth is designed with good air tightness and low water consumption, and the special high temperature foaming material improves the pressure life. It is equipped with a 16L large-capacity water Tank and an automatic water replenishment system.