Credit-Card Type Wet Film Gauge

The card-type wet film thickness gauge employs a toothed measurement principle. When the instrument is pressed vertically into the wet film, the scale at which the tooth tips contact the substrate indicates the film thickness. It is used for rapid on-site measurement of the thickness of liquid coatings such as paint and ink to ensure construction quality. It is suitable for monitoring wet film thickness on substrates such as metal, wood, and concrete.
Selection
When selecting, consider the measurement range to cover common coating thicknesses, with a tooth-shaped structure that requires wear and corrosion resistance. The handheld design ensures ease of operation, and clear scales facilitate reading. Match the range based on common coating types, and use stainless steel material to adapt to on-site environments. Verify the consistency of scale accuracy with industry standards.

Terms

Standards

Instruments

Made of stainless steel, the thickness is only 1.5mm, the range is 20~ 200μm, Division 20μm, the card design is convenient for quick measurement of wet-film Coating thickness on site.

$ 119.00

Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.

$ 146.00

Made of precision stainless steel, with a range of 50 to 950 μm, the 10-step tooth design can accurately measure wet film thickness, ensure painting mass and avoid material waste.

$ 109.00

Made of stainless steel, durable and repeatability; range 20~ 200μm, Division 20μm, step number of teeth 10, unilateral design is convenient for vertical pressing into wet-film measurement, in line with international standards.

$ 109.00

The stainless steel material is durable, the range is 10~ 100μm Division 10μm, the unilateral design is convenient for vertical pressing into the wet-film measurement, and the number of teeth 10 can accurately read the thickness value between the infiltrated and uninfiltrated teeth.

$ 109.00

In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.

$ 127.00

In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.

$ 127.00

Stainless steel material is sturdy and durable, with a range of 50-950 microns, Division 50 and 100 microns, and a compact shape of only 65 * 43 * 1.5mm, suitable for rapid measurement of wet film thickness on site.

$ 119.00

Made of medical grade stainless steel, Hardness up to HRC55, wet film thickness 75 μm, accuracy control within +/- 2 μm, suitable for a variety of flat surface Spreader applications.

$ 791.00

Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.

$ 180.00

The three-wheel structure design is adopted, and the center wheel contacts the film directly for reading. The measuring range is 0-500 μm and the indexing is 25 μm. It can perform nondestructive thickness measurement on plane and curved surface.

$ 186.00

Support HDMI, WIFI and SD card three output, 1920 * 1080 resolution, can directly control camera paraMeters through USB mouse, embedded image capture and video recording, suitable for a variety of detection scenes.

$ 1461.00

The three-wheel structure design is adopted, and the thickness of the center wheel contact film is directly read, with a range of 0-100 μm and a Graduation of 5 μm, which can be used for nondestructive measurement on planes and surfaces.

$ 186.00

Made of DAIDO 440C medical grade stainless steel, Hardness reaches HRC55, wet film thickness 125μm, application width 75mm, accuracy +/- 2μm, Spreader can be uniform on flat surface without adjustment.

$ 791.00

The three wheel structure design is adopted, and the thickness of the center wheel contact film is directly read, with a range of 0-1000 μm and a Graduation of 50 μm. Destructiveness measurement can be carried out on the curved surface, and the operation is simple and high accuracy.

$ 186.00

Articles

Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Laboratory rod coater for submicron wet film preparation of photoresist.
This article introduces the process of using a laboratory bar coater to prepare submicron wet films of photoresist.
Application of Karl Fischer Micro Moisture Meter in Moisture Control of Lithium Battery Electrolyte
The Karl Fischer micro-moisture analyzer is based on the Karl Fischer titration principle, which measures trace moisture in lithium battery electrolytes through the quantitative reaction between iodine and water.
Comparison Between Halogen Moisture Analyzer and Karl Fischer Moisture Analyzer in Plastic Moisture Detection
This article compares the differences between halogen moisture analyzers and Karl Fischer moisture analyzers in detecting moisture in plastics.
Selection and Differentiation of Karl Fischer Method and Halogen Method for Paint Moisture Analyzers
This article introduces two common methods for determining moisture in coatings: the Karl Fischer method and the halogen heating method.
The combination of hiding power chart paper and a spectrophotometer enables the digital evaluation of hiding power.
This article introduces how to combine hiding power cards with spectrophotometers to achieve digital assessment of hiding power.
Technical Details of Measuring Paint Contrast Ratio Using Black-and-White Checkerboard Method with Hiding Power Card
This article introduces a method for measuring the hiding power of coatings using black and white checkerboard paper.
Application of Wet Film Wheel Gauge in Continuous Measurement of Wet Film Thickness for Large-Area Coatings
The wet film wheel gauge is a mechanical tool used to measure the thickness of wet coatings, operating based on the geometric relationship of three coaxial disks (two parallel outer wheels on the sides and an eccentric inner wheel in the middle).
Operating specifications for on-site measurement of coating wet film thickness using wet film combs
This article introduces the operational standards for on-site measurement of coating wet film thickness using a wet film comb gauge. First, it explains the measurement principle of the wet film comb gauge, which involves estimating the thickness by observing the extent to which the teeth of the gauge are coated with the paint.
Test card paper for coatings is used for evaluating the appearance and film thickness consistency of coatings.
Coating test card is an integrated testing tool used to evaluate the appearance and film thickness uniformity of coatings.
Application of Coating Rate Cardboard in the Determination of Coating Rate for Architectural Coatings
Coating rate card paper is a standardized substrate used to determine the spreading rate of architectural coatings. It features a smooth surface and stable parameters, which help minimize the influence of substrate variations and environmental factors associated with traditional methods.
Vicat softening point tester measures the heat deflection temperature of special engineering plastics.
The Vicat softening point tester measures the temperature at which a needle penetrates a plastic sample to a specified depth by heating and applying a load, thereby evaluating the heat deflection temperature of special engineering plastics.
Vicat Softening Point Tester measures the heat resistance of plastics.
This article introduces how a Vicat softening point tester measures the heat resistance of plastics. During the test, the instrument applies a fixed load to the plastic sample and heats it at a constant rate. When the flat-ended needle penetrates the sample to a depth of 1 millimeter, the temperature at that moment is recorded, which is known as the Vicat softening point.
Selection of wet film thickness gauge range and accuracy requirements for comb teeth spacing.
When selecting a wet film thickness gauges, the key considerations are the measurement range and the accuracy of the comb teeth spacing. The range should cover the coating thickness with a slight margin to avoid being too small for measurement or too large, which could reduce resolution.
Selection of Moisture Analyzer: Applicability of Halogen or Karl Fischer Method for Materials
This article introduces the principles and application scenarios of halogen heating method and Karl Fischer method in moisture determination.