Ultrasonic Viscosity Meter

The ultrasonic viscometer emits high-frequency sound waves that penetrate the sample and measures the degree of sound wave attenuation to calculate viscosity. It is used for real-time monitoring of viscosity changes in fluids such as coatings and inks during production, making it suitable for online quality control.
Selection
Select the range and accuracy based on the characteristics of the material to be measured, taking into account temperature adaptability; choose probe materials and protection levels suitable for the working conditions; confirm that the output interface is compatible with the existing control system; and evaluate the convenience of cleaning and maintenance.

Terms

Standards

Instruments

With microwave and ultrasonic coordinated control function, 250ml container capacity with 1800W adjustable ultrasonic Power, infrared temperature sensor and magnetic stirring system, support a variety of reaction modes to expand applications.

$ 17178.00

Equipped with microwave and ultrasonic synergy function, 2000ml large-capacity reactor and 1800W ultrasonic power, support platinum resistance accurate temperature measurement and magnetic stirring, and realize multi-mode chemical reaction control.

$ 15887.00

With microwave and ultrasonic synergy function, support 500ml reaction vessel, ultrasonic Power 1800W can be fine-tuned, Frequency 20KHz, integrated infrared temperature control and magnetic stirring, suitable for a variety of synthesis conditions to accelerate the reaction.

$ 17178.00

It is equipped with ultrasonic and degassing cleaning modes, supports accurate temperature control within 80 ° C and 60-minute timing, and is designed with SUS304 stainless steel punching Tank without solder joints. The transducer has high conversion rate and ultrasonic power of 600W.

$ 315.00

Equipped with microwave ultrasonic individual and collaborative control functions, equipped with 2000ml reaction vessel and 1800W ultrasonic Power, supports infrared temperature measurement and magnetic stirring, and can achieve a variety of synthesis conditions.

$ 17178.00

With microwave ultrasonic separate control and coordination function, support 1000ml reaction capacity and 1800W ultrasonic Power, using infrared temperature sensor and magnetic stirringdevice, can realize multi-mode reaction operation.

$ 17178.00

With microwave ultrasonic separate and collaborative control function, using Platinum Resistance Sensor to achieve +/- 1 ℃ temperature control accuracy, equipped with 1800W adjustable ultrasonic Power and 1000W microwave output, support multi-stage program control and real-time response monitoring.

$ 15887.00

Using 40KHz 130W ultrasonic Nebulizer, liquid viscosity to adapt to 1-50mPa · s, equipped with AI-PID temperature control system, the maximum temperature of 500 ℃, to achieve accurate solution atomization and substrate temperature control, to meet the diverse experimental needs.

$ 24279.00

With 20-25KHz Ultrasonic Frequency and 1800W Maximum Power, it supports ultrasonic, homogeneous emulsification and vortex mixing operation at the same time, provides over-temperature overload alarm and remote control function, Glass parts are resistant to corrosion and high and low temperature.

$ 8465.00

The device uses 40KHz Ultrasonic Frequency, is equipped with 300W Heating power, supports 1-30 minute timing and 20-80 ℃ temperature regulation, ensuring deep cleaning and rapid dissolving of dirt.

$ 190.00

With ultrasonic and degassing dual cleaning mode, it supports accurate temperature control within 80 ° C and 60-minute timing. It adopts stainless steel punching Tank without solder joint design, resulting in high transducer conversion rate and long service life.

$ 140.00

It is equipped with microwave and ultrasonic separate control and coordination functions, supports platinum resistance temperature measurement and 1800W ultrasonic power, and is equipped with magnetic stirring and ultraviolet catalytic system, which can realize multi-stage program control and real-time data monitoring.

$ 15887.00

With ultrasonic and degassing two cleaning modes, support 14 temperature within 80 ℃ precise control and 60 minutes timing. SUS304 stainless steel punching Tank without solder joint design, the transducer conversion rate is high, long service life.

$ 251.00

With 4000W Ultrasonic Power and 50L processing capacity, it supports simultaneous operation of ultrasonic processing and mechanical stirring. It is made of high borosilicate Glass to withstand heat Impact and can store 20 sets of operating procedures.

$ 13080.00

Integrated ultrasonic vibration and high-speed shearing technology, maximum line speed of 47m/s, Processing capacity 2-10L, with Power continuous adjustment and automatic Frequency tracking function, suitable for high viscosity samples.

$ 4914.00

Articles

Application of High-Temperature Viscometer in Testing the Melt Viscosity Characteristics of Hot Melt Ink
This article introduces a method for testing the melt viscosity of hot-melt ink using a high-temperature viscometer. The test employs a rotational viscometer to measure the viscosity of three ink samples at different temperatures.
Application of Cone-and-Plate Viscometer in Determining the Rheological Curve of Non-Newtonian Fluids in UV Inks
This article introduces how a cone-plate viscometer measures the rheological curve of UV ink. UV ink is a non-Newtonian fluid whose viscosity changes with shear rate.
Lab Mixer Selection - Viscosity Determines Torque
This article mainly discusses how to select a laboratory mixer based on the viscosity of the material. The higher the viscosity, the greater the torque required. Low-viscosity liquids are suitable for high speed and low torque, while high-viscosity materials require low speed and high torque.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
The impact of temperature uniformity in laboratory water baths on viscosity measurement
This article discusses the importance of temperature uniformity in laboratory water baths for viscosity measurement. Viscosity is highly sensitive to temperature variations, and uneven temperature distribution within the water bath can lead to deviations in measurement results.
Guide to Selecting a Laboratory Rotational Viscometer for Coatings Development
This article introduces how to select a laboratory rotational viscometer in coatings research and development. It first explains the principle of rotational viscometers measuring viscosity based on shear resistance, and then points out that key parameters to consider during selection include measurement range, shear rate, temperature control, and rotor configuration.
The Zahn cup is used for the daily inspection of the viscosity of electrophoretic paint bath solutions.
This article introduces the application of the Zahn cup in daily inspections of the viscosity of electrophoretic paint bath solutions. The viscosity of electrophoretic paint affects coating quality, making daily inspections crucial. The Zahn cup is simple to operate, cost-effective, and suitable for rapid on-site measurements.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Desktop Viscometer Cups in Batch Sample Screening at Quality Inspection Centers
This article introduces the application of desktop viscosity cups in batch sample screening at quality inspection centers. Viscosity cups estimate viscosity by measuring the outflow time of fluids, making them suitable for rapid screening.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
High-temperature viscometer measures the flow behavior of powder coatings in the molten state.
This article introduces the use of a high-temperature viscometer to measure the flow behavior of powder coatings in their molten state. Powder coatings need to melt and flow before curing, a process that directly affects the smoothness and performance of the coating.
Temperature-controlled Rotational Viscometer Simulates Coating Rheology in Construction Environments
This article introduces how to use a temperature-controlled rotational viscometer to simulate construction environments in order to study the flow characteristics of coatings. The viscosity of coatings changes under different temperatures and shear conditions, which affects their application performance.
When selecting a laboratory disperser, it is essential to evaluate the dispersion capacity and the speed range.
When selecting a laboratory disperser, it is crucial to evaluate the dispersion capacity and speed range. The dispersion capacity should be determined based on parameters such as material viscosity and solid content to avoid uneven dispersion or localized overheating caused by excessive or insufficient capacity.
Rotational rheometer measures the viscosity and processing performance of polymer melts.
A rotational rheometer applies a controlled shear field to measure rheological parameters such as the viscosity of polymer melts. The melt typically exhibits shear-thinning behavior, where its viscosity changes with the shear rate, directly affecting processing methods such as extrusion and injection molding.