Digital Dual Rockwell Hardness Tester

The digital dual Rockwell hardness tester measures the hardness of materials by applying a preload and a main load to the surface, using an electronic sensor to measure the difference in indentation depth and automatically calculating the hardness value. The result is directly displayed digitally. It is used for testing the Rockwell hardness and surface Rockwell hardness of metal materials, and is applied in heat treatment, machining, and quality control to inspect the hardness of components.
Selection
When selecting, consider the type and hardness range of the test material, ensuring the instrument complies with standards such as GB/T230 and ASTM E18. Check that the indenter type and test force match the sample, and ensure the digital display readings are stable and clear. Choose an appropriate worktable based on the sample size, and review the instrument’s calibration certificate and after-sales service support.

Terms

Standards

Instruments

High Accuracy Stepping Control system, support HR, HB, HV conversion scale, large test space, Built-in Printer and RS-232 interface, suitable for a variety of hardness of materials.

$ 3139.00

With three Adjustments, it can simultaneously measure Richter, Brinell, Rockwell and other Hardness values, indication Repeatability 6HLD, support 360 ° measurement direction, standard D-type Impact device and optional Miscellaneous type, anti-vibration Impact electromagnetic interference.

$ 348.00

Split design can be matched with a variety of Impact devices, using digital dual coil probe technology, Measurement accuracy of +/- 6HL, support 360 ° automatic direction compensation, built-in a variety of Hardness standard automatic conversion, with statistical and QC two Measurement modes.

$ 574.00

Measurement accuracy up to +/- 6HL with digital dual coil probe technology, support for a variety of Hardness standard automatic conversion, with 360 ° direction automatic compensation function, can be adapted to four different Impact devices to meet diverse measurement needs.

$ 958.00

The Che design can be operated with one hand, the test range is equivalent to Brinell 25-135HB, and the measurement can be completed on one side without support. It has the function of extreme value retention and average calculation of 29 sets of data.

$ 735.00

Split design with four Impact devices, digital dual coil probe technology to ensure +/- 6HL Measurement accuracy, automatic direction compensation to achieve 360 ° measurement, support a variety of Hardness standard automatic conversion, to meet different detection needs.

$ 335.00

Digital probe technology implementation signal direct processing, strong anti-interference ability, Measurement accuracy +/- 12HL, built-in direction Sensor automatic compensation Impact direction error, support 8 kinds of Hardness standard automatic conversion, weight only 270 grams easy to carry.

$ 231.00

Using split design, the probe and the host are connected by aviation plug, equipped with digital dual coil probe technology, Measurement accuracy can reach +/- 6HL, support a variety of Hardness standard automatic conversion, with 360 ° direction automatic compensation function.

$ 335.00

Support six kinds of Hardness standard conversion, equipped with high luminance LED backlight, metal shell anti-interference, standby time up to 100 hours, can store 600 sets of data, adapt to various harsh environments.

$ 425.00

The device adopts D-type Impact device, supports 360 ° measurement, can display a variety of Hardness standards, has 600 sets of Data storage capacity, is small in size and weighs only 0.2kg, and has a standby time of 100 hours. It is suitable for small spaces and field environments.

$ 192.00

The use of New material has a long life, stable fullness point and correction point, and can measure 0.6-8 mm thickness materials. Hardness value can be converted into Vickers, Rockwell and other standards.

$ 725.00

The integrated structure is compact and portable, and the dual-coil technology is used to ensure good Repeatability and Measurement accuracy. The built-in Direction Sensor automatically compensates for errors, and supports a variety of Hardness standard conversions.

$ 180.00

Digital display design, compact and easy to operate, Measuring accuracy, low power consumption, easy to carry, suitable for field and laboratory rapid Hardness detection.

$ 477.00

The use of New material has a long life, stable fullness point and correction point, Hardness value can be converted into Vickers Rockwell Brinell, the range is 0-20HW, and the accuracy is 0.5HW, which is suitable for workpieces with a thickness of 0.6-13 mm.

$ 725.00

Suitable for medium Hardness Rubber and Plastic, Measurement range 0-100HC, resolution 0.1HC. Measurement modes of real-time, peak, automatic timing and average value can be connected to computer for data Linear dispersion analysis and storage.

$ 590.00

Articles

Comparison of Single-Column and Dual-Column Tensile Testing Machines in Plastic Film Testing Selection
This article introduces the differences between single-column and dual-column tensile testing machines in plastic film testing.
Ultrasonic Thickness Gauge Selection: Technical Considerations for Probe Configuration and Measurement Modes
This article primarily introduces the technical factors to consider when selecting an ultrasonic thickness gauge. In terms of probe configuration, the frequency affects both resolution and penetration depth, while crystal size determines adaptability to curvature and surface conditions. Dual-element probes offer a smaller dead zone compared to single-element probes, and delay-line probes are suitable for thin-wall and high-temperature applications.
Cupping test instrument detects the cracking resistance of coatings under deformation.
This article introduces how the cupping test instrument detects the cracking resistance of coatings under deformation. It uses a spherical punch to uniformly press against the back of the sample, causing the coating to bulge with the substrate, simulating biaxial stretching until the coating cracks. The indentation depth at this point is recorded as the key indicator.
Automatic potentiometric titration method for determining hydrogen peroxide concentration by redox method
This article introduces a method for determining the concentration of hydrogen peroxide using an automatic potentiometric titrator. It is based on the redox reaction between potassium permanganate and hydrogen peroxide under acidic conditions, with the titration endpoint automatically determined by the abrupt change in potential.
Application of Two-Step Method with Pre-Coating and Fine-Coating in Eliminating Bubble Defects for Dual-Blade Coater
The dual-blade coater employs a two-step method of pre-coating and precision coating to eliminate bubble defects during the coating process. In the pre-coating stage, high shear force is applied to break the bubbles in the slurry, causing them to rupture and rise to the surface. The precision coating stage then precisely controls the coating thickness, removing any remaining bubbles to form a uniform wet film.
Differences between single-beam and double-beam structures in paper stiffness testers
Paper stiffness testers come in both single-beam and double-beam structures. The choice should be based on testing standards, sample thickness, and precision requirements.
Comparison of Dual-Principle Instruments: Magnetic Induction vs. Eddy Current for Coating Thickness Measurement
This article compares the principles of two coating thickness gauges. The choice of method depends on the substrate material: magnetic induction is used for magnetic metals, while eddy current is applied for non-magnetic metals.
Cupping tester evaluates the ductility of coatings.
The cupping tester is a detection device used to evaluate the ductility of coatings under biaxial tension. During the test, the punch presses the sample into the die until the first continuous crack appears in the coating, at which point the penetration depth of the punch is recorded as the cupping depth.
How does a roll-to-roll coating machine achieve double-sided coating?
How does a roll-to-roll coating machine achieve double-sided coating? Double-sided coating is a process that simultaneously or sequentially applies functional coatings to both sides of a flexible substrate (such as film, paper, or metal foil).
Difference between dual-beam and array spectrophotometers
This article aims to systematically elucidate the core differences between double-beam and array-type spectrophotometers in terms of working principles, optical structures, performance characteristics, and applicable scenarios, providing clear technical references for professionals in related fields.
Pendulum Hardness Determination: Comparison of Applicability between Double Pendulum Method and Compound Pendulum Method
This article compares two pendulum methods for measuring coating hardness. The choice of method should consider material hardness and testing conditions, and both methods require standardized calibration and sample preparation.
When selecting a drop testing machine, whether to choose a single-arm or double-arm configuration depends on the size and weight of the packaging.
When selecting a drop tester, the choice between a single-arm or double-arm model mainly depends on the size and weight of the packaging. For small, lightweight, and regularly shaped items, a single-arm tester is sufficient. However, for larger, heavier, or irregularly shaped items, it is better to choose a double-arm tester, as it offers greater stability and ensures more accurate test results.