Hydrogen Chloride Moisture Analyzer

The hydrogen chloride moisture analyzer is based on the coulometric method principle. It absorbs moisture from the gas in an electrolytic cell, where the moisture reacts with iodine. The amount of electricity required for electrolysis is measured and converted into moisture content. This analyzer is used to detect trace moisture in hydrogen chloride gas in industries such as chlor-alkali and chemical production, ensuring production safety and process control.
Selection
When selecting, consider that the measurement range must cover the process requirements, paying attention to the instrument's detection limit and accuracy indicators. Check the lifespan and maintenance cycle of the electrolytic cell, ensuring it adapts to on-site gas temperature and pressure conditions. Confirm the corrosion resistance and compatibility with the sample, and evaluate the ease of operation and data output methods.

Terms

Standards

Instruments

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and automatic Zero tracking function, support a variety of signal output interfaces and remote monitoring.

$ 638.00

Adopt pump-suction sampling and dust-proof design, equipped with dust filter, range 0~ 500ppm, resolution 1ppm, Response Time T90 ≤ 20s, can customize paraMeter settings and store 120,000 sets of data.

$ 1042.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions.

$ 638.00

Electrochemical sensor technology, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, Intrinsic Safety (IS) design and automatic Zero tracking function, support multiple signal output and remote monitoring.

$ 764.00

Designed for chloride ion composite ElectRode, provides stable calibrating performance, Encasement size 250ml, to ensure long-term use Reliability and measurement conformity.

$ 110.00

Electrochemical sensor, range 0-200ppm, accuracy +/- 2% F. S, with intrinsically safe circuit design and explosion-proof certification, support for a variety of signal output interfaces, Response Time is less than 10 seconds, suitable for harsh industrial environments.

$ 764.00

Using Industrial-grade Sensor and Microcontrol Technology, Response Time is less than 60 seconds, and Sensor life is 2 years. It has waterproof, dustproof and explosion-proof characteristics, and is detected by natural diffusion. Sensitivity and Repeatability are good.

$ 248.00

Adopt pump suction sampling, Response Time T90 ≤ 20 seconds, detection accuracy ≤ +/- 3%, IP65 Protection Rating, equipped with dust filter, adapt to harsh environment, support multi-Sensor expansion.

$ 603.00

Electrochemical sensor, resolution up to 0.1ppm, Response Time less than 60 seconds, with sound, light and vibration triple alarm, IP65 Protection Rating to adapt to harsh environments.

$ 235.00

The explosion-proof structure design, Response Time is less than 30 seconds, resolution of 0.1ppm, can detect a variety of gas concentrations, with sound and light alarm function to ensure safety monitoring.

$ 251.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds. Support a variety of signal output and wireless transmission, with explosion-proof structure and remote alarm function.

$ 280.00

Using 32-bit processor and 24-bit ADC chip, support 6-level calibrated to ensure accuracy. With 4-20mA, RS485 and relay output, transmission distance up to 1.2km, Protection Rating IP65, long-term use in harsh environments.

$ 620.00

Using halogen lamp heating source, moisture temperature accuracy +/- 0.5%, moisture readability 0.02%~ 0.1%, heating temperature range 50 ℃ to 180 ℃, support timing automatic end measurement, with RS232 communication interface.

$ 585.00

Using halogen lamp heating technology, fast drying samples and real-time display Moisture content, Moisture Precision up to +/- 0.2%, Heating Temperature range 80~ 160 ℃, suitable for a variety of sample detection.

$ 359.00

Using pyrolysis weight principle design, equipped with halogen heating unit, moisture readability of 0.02%, heating temperature up to 200 ℃, support automatic manual timing test, real-time display Moisture content change process.

$ 441.00

Articles

Selection Differences Between Rapid Moisture Analyzers and Coulometric Moisture Analyzers
This article mainly introduces the differences between a rapid moisture analyzer and a coulometric moisture analyzer.
Karl Fischer moisture analyzer measures the water content of resin particles.
This article introduces the method of measuring the moisture content of resin pellets using a Karl Fischer moisture meter.
Karl Fischer Moisture Analyzer for Determining Moisture Content in Coatings
This article introduces a method for determining the moisture content in coatings using a Karl Fischer moisture titrator. It is based on the quantitative reaction of reagents such as iodine and sulfur dioxide with water, and calculates the moisture content by measuring the amount of reagent consumed during titration.
Karl Fischer Moisture Analyzer Determines Moisture Content in Powder Coatings
This article introduces the method of determining the moisture content in powder coatings using a Karl Fischer moisture analyzer. Excessive moisture content in powder coatings can affect the quality of the coating, leading to issues such as bubbles. The Karl Fischer method measures moisture through the quantitative reaction of iodine and sulfur dioxide, which is divided into volumetric and coulometric methods.
Karl Fischer moisture analyzer detects moisture content in hot melt adhesives.
This article introduces the method of using a Karl Fischer moisture analyzer to detect the moisture content in hot melt adhesives. The Karl Fischer method is based on the quantitative reaction of iodine, sulfur dioxide, and water, and calculates the moisture content by measuring the amount of iodine consumed.
Karl Fischer Moisture Analyzer for Determining Water Content in Coatings
This article introduces the method for determining the water content in coatings using the Karl Fischer moisture analyzer. The principle is based on the quantitative reaction of iodine and sulfur dioxide in the reagent with water. The coulometric method is commonly used to generate iodine through electrolysis and calculate the moisture content by measuring the electrical charge.
What is the deviation between the moisture meter's rapid moisture measurement and the oven method?
This article primarily compares the differences between rapid moisture analyzers and traditional oven methods in measuring moisture. Understanding these differences helps in using rapid moisture analyzers more appropriately, ensuring data reliability while maintaining efficiency.
Karl Fischer Moisture Titrator for Determining Solvent Moisture
The Karl Fischer moisture meter determines solvent moisture based on the quantitative reaction of iodine and sulfur dioxide with water in an alkaline environment.
Halogen Moisture Analyzer Rapidly Determines the Moisture Content of Samples
The halogen moisture analyzer utilizes the principle of thermal gravimetric analysis, rapidly heating the sample with a halogen lamp to evaporate moisture. The built-in balance monitors mass changes in real-time and automatically calculates the moisture content.
Difference between halogen moisture analyzer and Karl Fischer moisture analyzer
The core difference between halogen moisture analyzers and Karl Fischer moisture analyzers lies in their measurement principles. Halogen moisture analyzers are based on the thermogravimetric method, while Karl Fischer moisture analyzers rely on titration principles, either volumetric or coulometric, which involve quantitative chemical reactions specifically targeting water molecules.