Carbon Monoxide Infrared Analyzer

Carbon monoxide infrared analyzers operate on the principle that gas molecules absorb infrared radiation at specific wavelengths. By measuring the attenuation of infrared light intensity, they calculate the concentration of CO. These instruments are used to detect CO levels in environmental and industrial exhaust gases, and are applied in scenarios such as combustion efficiency monitoring and safety alarms.
Selection
When selecting, consider the measurement range to match detection needs, response speed to adapt to on-site conditions, and anti-interference capability to handle the impact of coexisting gases. Pay attention to the sensor lifespan and maintenance cycle, ensure the device's protection rating suits the installation environment, and confirm that the data output interface meets system integration requirements.

Terms

Standards

Instruments

Using electrochemistry principle to detect carbon monoxide, with a range of 0~ 1000ppm, with four Alarm modes and wireless data transmission functions, support temperature compensation algorithm and a variety of usage methods.

$ 254.00

Using infrared NDIR detection principle, range 0-5000ppm, Response Time ≤ 30S, support 4-20mA, RS485 and switch output, flameproof structure design, suitable for hazardous environment.

$ 1622.00

Electrochemical sensor, range 0~ 1000ppm, with automatic zero correction and temperature compensation function, flameproof design is suitable for dangerous areas, support remote infrared debugging.

$ 146.00

Electrochemical sensor, range 0-1000ppm, with automatic zero correction and temperature compensation function, support 4-20mA and RS485 output, infrared remote control debugging, suitable for dangerous areas.

$ 162.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with automatic Zero tracking and temperature compensation function, explosion-proof design for dangerous places, support a variety of signal output interfaces.

$ 682.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S., with intrinsically safe circuit design and explosion-proof certification, support for multiple output interfaces and automatic Zero tracking, suitable for harsh industrial environments.

$ 682.00

Electrochemical sensor detects 0-1000ppm carbon monoxide, Response Time is less than 60 seconds, through LCD display and buzzer grading alarm, portable design weighs only 115 grams.

$ 170.00

Electrochemical sensor, range 1000ppm, with automatic zero correction and temperature compensation functions, support 4~ 20mA and RS485 output, infrared remote control debugging, suitable for dangerous areas 1 and 2.

$ 172.00

Pump suction sampling and infrared Sensor technology, range 0~ 2000ppm, resolution 1ppm, Response Time ≤ 20s, with IP65 Protection Rating and Dust Filter, adapt to harsh environment.

$ 507.00

Electrochemical sensor, range 1000ppm, with automatic zero correction and temperature compensation, flameproof design for hazardous areas, support 4-20mA and RS485 output.

$ 183.00

Electrochemical sensor, range 1000ppm, Response Time T90 ≤ 60 seconds, with automatic zero correction and temperature compensation function, support flameproof design for dangerous areas, stable and Sensitivity.

$ 162.00

Using infrared NDIR detection principle, range 0-500ppm, accuracy ≤ +/- 1% F. S, Response Time ≤ 30 seconds, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote monitoring capability.

$ 848.00

Imported Electrochemical sensor, Response Time less than 10 seconds, detection accuracy +/- 2% F.S., with explosion-proof design and a variety of output interfaces, support remote monitoring and automatic Zero tracking, adapt to harsh industrial environment.

$ 682.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds; with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions, strong anti-interference ability.

$ 361.00

Electrochemical sensor, detection accuracy +/- 2% F. S, Response Time less than 10 seconds, with intrinsically safe circuit design and explosion-proof certification, support a variety of signal output and remote monitoring functions, strong anti-interference ability.

$ 682.00

Articles

The use of gravure proofing machines in the comprehensive evaluation of gravure ink printability and drying performance.
This article explores how a gravure proofing press can be used to comprehensively evaluate the printability and drying properties of gravure inks. The experiment tested the dot sharpness, transfer rate, and leveling properties of different inks using standard equipment, while recording drying times through the filter paper method and infrared temperature measurement.
UV-Vis-NIR spectrophotometer measures the transmittance of anti-reflection coatings.
This article introduces the method of measuring the transmittance of anti-reflective coatings using a UV-Vis-NIR spectrophotometer. The instrument is based on the Beer-Lambert law, calculating transmittance by comparing the light intensity of the sample and the reference, covering a wide spectral range from ultraviolet to near-infrared.
Performance Comparison of Electrochemical Sensors and Infrared Sensors in Multi-Gas Detectors
This article compares the performance of electrochemical sensors and infrared sensors in multi-gas detectors.
Xenon lamp aging test chamber for testing coating weatherability.
Xenon lamp aging test chambers accelerate the testing of weather resistance for materials such as coatings in the laboratory by simulating the ultraviolet, visible, and infrared portions of sunlight, while controlling conditions like temperature, humidity, and water spray.
How to Choose the Right Spectrophotometer
When selecting a spectrophotometer, it is essential to start from the actual analytical needs, clearly defining the required wavelength range (ultraviolet, visible, or infrared) and the type of detection. Key evaluations should focus on core specifications of the optical system, such as wavelength accuracy, beam type, and stray light levels.