VOC Detector

VOC detectors capture volatile organic compound molecules through gas sensors, generating electrical signals that are converted into concentration values. They are used for on-site monitoring of industrial exhaust gases, indoor air quality, and environmental inspections, enabling rapid identification of organic pollutants such as benzene and aldehydes.
Selection
When selecting, consider the matching requirements for the types of gases to be detected and the measurement range, and pay attention to the sensor's anti-interference capability and service life. Portable devices are suitable for inspections, while fixed ones are used for continuous monitoring. The calibration cycle and maintenance costs should be evaluated in conjunction with the frequency of use.

Terms

Standards

Instruments

It can simultaneously detect 7 paraMeters such as PM2.5, formaldehyde, and TVOC, with an accuracy of +/- 10%. It is equipped with a 2.8-inch true color screen to display real-time trend charts, and supports 5000 data records and dual national standard selection.

$ 189.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds, with explosion-proof structure and a variety of signal output interfaces, support remote monitoring and linkage control.

$ 332.00

Using MCU chip to achieve low power consumption operation, detection error ≤ +/- 3% F. S, Response Time ≤ 30 seconds; with flameproof structure and a variety of signal output, support remote monitoring and customized range, through a number of international safety certifications.

$ 332.00

Using PID Sensor technology, range 0~ 500ppm, resolution 0.1ppm, support 1-6 Sensor expansion, with a variety of signal output modes, including 4-20mA, RS485 and relay output, Protection Rating IP65, suitable for harsh environments.

$ 1818.00

Using 32-bit microprocessor and 24-bit ADC chip, equipped with 2.4-inch high definition display, supports 1-6 Sensor configurations, with 4-20mA, RS485 and other signal output, Protection Rating up to IP65, Response Time ≤ 20 seconds.

$ 545.00

Pump-suction sampling and imported Electrochemical sensor, Response Time ≤ 20 seconds, resolution 0.01ppm, support 1-5 Sensor expansion, IP65 Protection Rating, suitable for harsh environments.

$ 754.00

Pump-suction sampling and a variety of detection principles, Response Time ≤ 20 seconds, accuracy ≤ +/- 3%, built-in 3800mAh battery, support 120,000 sets of Data storage and Temperature Humidity detection.

$ 527.00

Adopt PID light ion detection principle, range 0-50ppm, Response Time ≤ 30S, with explosion-proof structure, multiple signal output and remote alarm function, support customized wireless transmission.

$ 1171.00

Adopt PID photoion detection principle, range 0-50ppm, Response Time ≤ 30S, support 4-20mA, RS485 and wireless signal output, with explosion-proof structure and remote monitoring capability.

$ 1171.00

Pump-suction sampling and PID Photoion Sensor technology, Response Time ≤ 20 seconds, resolution of 0.001 ppm, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 2557.00

Using ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³, equipped with independent variable frequency wind speed adjustment device, Modular design is easy to maintain, and the operating power is as low as 1.2kw.

$ 25602.00

Equipped with 2.4-inch high definition color screen, supports 1-6 Sensor expansion, with 4-20mA and RS485 output, Response Time ≤ 20 seconds, Protection Rating IP65, suitable for harsh industrial environments.

$ 583.00

Adopt ultra-low VOC background concentration control technology, background concentration formaldehyde ≤ 0.006mg/m ³; equipped with independent variable frequency wind speed adjustment device, the wind speed range is 0.1-1 m/s; Modular design is easy to maintain, and the integrated gas supply purification system is easy to operate.

$ 35348.00

Pump-suction sampling and PID photoion technology, detection accuracy of +/- 3%, Response Time ≤ 20 seconds, IP65 Protection Rating and explosion-proof certification, support for multi-Sensor expansion and Data storage functions.

$ 1532.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Articles

Application of Gravure Printing Proofer in Water-based Ink Proofing and Pinhole Defect Evaluation
This article introduces how the gravure printability tester is used for water-based ink proofing and pinhole defect evaluation. Water-based inks are environmentally friendly but prone to tiny pinhole defects. The instrument enables standardized sample preparation and reduces human interference by controlling parameters such as cell depth and doctor blade angle.
Use of Fluorescence Spectrophotometer in Measuring Excitation and Emission Spectra of Anti-Counterfeiting Fluorescent Inks
This article introduces the application of fluorescence spectrophotometry in the spectral measurement of anti-counterfeiting fluorescent inks, including instrument calibration, sample preparation, and methods for measuring excitation and emission spectra.
Spectrophotometer measures ink spectral reflectance and opacity.
This article introduces how to measure the hiding power of ink using a spectrophotometer. The instrument irradiates the ink sample, measures its reflectance within the visible light spectrum, and calculates the hiding power using the Kubelka-Munk model.
Cost-performance analysis of single-channel versus multi-channel switching modules when selecting a laboratory ion meter.
This article compares the cost-effectiveness of single-channel and multi-channel switching modules for laboratory ion meters. Single-channel devices have lower purchase costs, but additional instruments are required for each additional detection parameter. Multi-channel units have higher initial investment, but when testing more than three parameters, the total cost over three years is lower and the sample throughput is greater.
Application of Spray Coating Machines in the Encapsulation of Flexible Electronic Devices
This paper introduces the application of spray coating machines in the encapsulation of flexible electronic devices.
Extended Application of Paper Water Absorption Tester in the Dispersibility Evaluation of Tissue Paper
This article explores how to extend the application of an instrument originally used for testing the water absorption capacity of paper to evaluate the dispersibility of tissue paper.
Flexographic proofing press is used for evaluating the printability of water-based inks on kraft paper.
This article explores the use of flexographic proofing printability testers to evaluate the printing performance of water-based inks on kraft paper. The instrument simulates actual printing conditions, enabling quantitative analysis of key parameters such as ink transfer rate, print contrast, and dot gain.
The Impact of Cooling Circulating Water Chillers on the Temperature Stability of Digesters
The cooling circulator helps maintain a stable temperature for the digester by circulating the cooling medium, thereby improving the repeatability of experiments. Its working principle involves using a refrigeration system to lower the water temperature, and then circulating the cooled water to the digester through a circulation pump to absorb excess heat.
Key Operational Points of Solvent Resistance Tester in Evaluating Coating Chemical Resistance
This article introduces the key operational points of the solvent rub resistance tester in evaluating the chemical resistance of coatings. The instrument simulates friction and chemical contact, recording the number of rubs before coating failure to assess performance.
High-temperature viscometer evaluates the flow characteristics of ceramic coatings before sintering.
This article introduces how to use a high-temperature viscometer to evaluate the flow characteristics of ceramic coatings before sintering. During measurement, the instrument detects changes in the viscosity of the coating sample under simulated sintering temperature conditions using rotational or oscillatory principles.
Practical Guide to Selecting Rotors and Speeds for Rotational Viscometers
A rotational viscometer measures viscosity by detecting the resistance encountered by a rotor rotating in the sample. When selecting a rotor, it is necessary to consider the estimated viscosity range of the sample, ensuring that the torque reading falls within 10% to 90% of the instrument's measurement range, while also taking into account the sample volume and rheological properties.
Difference between Black Panel Temperature and Black Standard Temperature in Light Aging Test Chambers
In the light aging test chamber, black panel temperature and black standard temperature are two distinct temperature indicators. The black panel temperature is measured using a black metal panel sensor, reflecting the immediate heating effect on the material surface under light exposure and is significantly influenced by air convection.
High-temperature aging test chamber accelerates life testing of electronic components.
The high-temperature aging test chamber accelerates the physical and chemical changes within electronic components by simulating high-temperature environments, thereby predicting their long-term performance and failure modes.
Selection Recommendations for Paint Film Cross-Cut Testers Based on Different Adhesion Testing Requirements
This article mainly discusses how to choose the appropriate paint film cross-cut tester based on different adhesion testing requirements.
Evaluation of Coating Adhesion Grade by Cross-Cut Tester Combined with Tape Method
This article introduces the method of evaluating coating adhesion using a paint film cross-cut tester combined with the tape method.