Odor Detector

Odor detectors capture gas molecules through sensors to generate changes in electrical signals, converting concentration into numerical values for display. They are used for on-site monitoring of odor intensity in scenarios such as industrial exhaust emissions and wastewater treatment, assisting in environmental management and emission control.
Selection
When selecting, consider the compatibility of the gas types to be detected with the sensors, ensure the measurement range covers the actual concentration levels, check that the explosion-proof rating is suitable for the operating environment, confirm that data recording functions and response speed meet monitoring requirements, and regularly calibrate and maintain sensor sensitivity.

Instruments

Electrochemical sensor, range 0-5ppm, resolution of 0.001ppm, Response Time ≤ 30 seconds, with flameproof design, support 4-20mA, RS485 and wireless signal output, can be operated by remote control without opening the lid.

$ 357.00

Platinum Sensor provides linearly stable measurement results, Conductivity Detector cell constant K = 10, Measurement range 0 to 200mS/cm, suitable for high Conductivity Detector liquid detection.

$ 106.00

Conductivity Detector cell constant K = 0.1, built-in temperature sensor real-time sensing sample temperature, suitable for low Conductivity Detector liquid measurement.

$ 314.00

Using platinum sheet material, Conductivity Detector cell constant is 10, suitable for high conductivity environment water measurement, equipped with three core socket interface, no temperature compensation design.

$ 102.00

Using platinum sheet material, Conductivity Detector cell constant 0.1, no temperature compensation function, suitable for pure water and ultra-pure water and other water quality measurement, optional Glass flow Tank.

$ 185.00

Using platinum sheet material, Conductivity Detector cell constant is 1, Measurement range covers 2.0~ 200 µS/cm, suitable for conventional water detection, interface is three-core socket, no temperature compensation function.

$ 99.00

Conductivity Detector 1 with platinum sheet material. Measurement range from 200 µS/cm to 200 mS/cm. Suitable for environmental and conventional water detection without temperature compensation.

$ 99.00

Platinum Sensor ensures linear and stable measurement, built-in temperature sensor real-time compensation, Measurement range of 0-200mS/cm, suitable for high Conductivity Detector liquids, equipped with 5 Meters low noise Shielding cable.

$ 140.00

Using Platinum Sensor to ensure linear and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 20mS/cm, suitable for conventional liquid detection, Operating temperature 0~ 80 ℃.

$ 102.00

Platinum Sensor ensures fast and stable measurement, Conductivity Detector cell constant K = 1, Measurement range 0~ 35mS/cm, Glass shell is durable, suitable for conventional liquid detection.

$ 185.00

Fillable internal reference solution design with circular Glass sensitive membrane and annular ceramic liquid junction for low Conductivity Detector samples ensures measurement Stability and accuracy.

$ 330.00

Conductivity Detector measurement principle, measurement range 0~ 95%, resolution of 0.1%, Response Time of only 1 second, with temperature compensation and automatic shutdown function, portable design weight of about 175 grams for on-site use.

$ 144.00

Glass bulb sensitive film, Measurement range 0-14pH, suitable for low Conductivity Detector sample measurement under closed static conditions, Dimension Φ 12 × 120mm.

$ 89.00

Conductivity Detector Measurement principle, Measurement range 0-50%, Response Time less than 1 second, with temperature and humidity compensation function, split design for quick detection on site.

$ 230.00

Conductivity Detector temperature compensation technology, Measurement range 8~ 40%, accuracy +/- 0.5%, Response Time 1 second, with backlight display and automatic shutdown function, portable design weight only 175 grams.

$ 267.00