Roller type design, range 0~ 500μm, stainless steel material to ensure durability, suitable for on-site rapid measurement wet film thickness, in line with a number of execution standards.
Dedicated to Coating thickness Gauge calibrating, ensure accurate thickness measurement, suitable for F type equipment, improve Reliability.
Double pointer design with peak holding and continuous load indication function, external tolerance indicator to facilitate force value judgment, Maximum Measured value 10KN, suitable for electromagnetic interference occasions.
Dual pointer design with peak holding and continuous load indication function, Maximum Measured value 20KN, with external tolerance indicator to facilitate force value judgment, suitable for electromagnetic interference environment.
Double pointer design to achieve peak holding and continuous load indication, external tolerance indicator to facilitate force value judgment, Maximum Measured value 200KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
The three-wheel structure design is adopted, and the center wheel contacts the film directly for reading. The measuring range is 0-500 μm and the indexing is 25 μm. It can perform nondestructive thickness measurement on plane and curved surface.
Double pointer design for easy reading, Pin Travel 0~ 2.5mm, Measurement range 0~ 100HD, error +/- 1HD, lightweight and portable only 0.16kg, suitable for on-site Hardness detection.
With dual pointer design can display peak and continuous load at the same time, external tolerance indicator is easy to judge the force value, the maximum Measured value is 100KN, Indication Error +/- 2% FS, suitable for electromagnetic interference environment.
Made of precision stainless steel, with a range of 50 to 950 μm, the 10-step tooth design can accurately measure wet film thickness, ensure painting mass and avoid material waste.
In line with ISO2808-1974 standard, the range is 0~ 150μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction control.
With tracking pointer and peak pointer double pointer design, pressing needle Travel 0-2.5 mm, Measurement range 10-90Hc, suitable for material testing with pressure above 0.049MPa when the compression rate is 50%, and can be matched with test bracket to improve Stability.
The stainless steel material is durable, the range is 10~ 100μm Division 10μm, the unilateral design is convenient for vertical pressing into the wet-film measurement, and the number of teeth 10 can accurately read the thickness value between the infiltrated and uninfiltrated teeth.
Can be used with A type or C type Shore DuroMeter, fixed load weight mass 0.75 +/- 0.05kg, hardness Gauge clamping Rod connection size M7x0.5mm, improve hardness testing accuracy and Stability.
The three-wheel structure design is adopted, and the thickness of the center wheel contact film is directly read, with a range of 0-100 μm and a Graduation of 5 μm, which can be used for nondestructive measurement on planes and surfaces.
In line with ISO2808 standard, the range is 0~ 500μm, the accuracy is not more than 5μm, can measure the wet film thickness and estimate dry-film thickness, suitable for laboratory and pRoduction site.