Handheld ISO Flow Cup

The handheld ISO outflow cup determines viscosity by measuring the time it takes for the coating to flow out from a standard orifice at the bottom of the cup. It is used for on-site rapid testing of liquid fluidity and is suitable for quality control in industries such as paints and inks.

Instruments

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 8mm, viscosity measurement range 600~ 2000cSt, outflow time 30~ 100s, in line with ISO and GB standards.

$ 151.00

Using 5mm flow hole design, the measurement viscosity range of 91~ 326cSt, aluminum alloy Cup body with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

3Mm flow hole design, measurement of 7~ 42cSt viscosity range, suitable for Newton type liquid outflow time test, the Cup body is light and durable.

$ 170.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, the aperture is 5mm, and the viscosity measurement range is 91~ 326cSt, which is suitable for the determination of Newton-type liquid outflow time.

$ 146.00

6Mm flow hole design, measurement viscosity range 188~ 684cSt, aluminum alloy Cup with stainless steel filter to ensure Test accuracy, suitable for Newton type liquid outflow time measurement.

$ 170.00

Using aluminum alloy Cup body and stainless steel outflow nozzle, aperture 3mm, measurement viscosity range of 7~ 42cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Made of stainless steel, with a flow hole diaMeter of 3.0 +/- 0.01mm and a viscosity range of 7-40mm ²/s, it is suitable for testing the outflow time of Newtonian or near-Newtonian liquids and meets ISO and GB standards.

$ 143.00

It adopts aluminum alloy Cup body and stainless steel outflow nozzle structure, the outflow aperture is 6mm, and the outflow time of Newton-type liquid in the viscosity range of 188~ 684cSt can be measured, which meets the test requirements of international standards.

$ 146.00

Adopt aluminum alloy Cup body and stainless steel outflow nozzle, aperture 4mm, viscosity measurement range 34~ 135cSt, in line with international standards to ensure measurement accuracy.

$ 146.00

Using 4mm stainless steel nozzle design, Measurement accuracy up to 34~ 135cSt viscosity range, anti-oxidation material to ensure long-term stable use, Handheld structure for easy operation.

$ 580.00

Using aluminum alloy Cup body and stainless steel filter, the outflow aperture of 3mm, 4mm, 6mm optional, Measurement range of 30~ 100 seconds, in line with international general viscosity test standards.

$ 238.00

Measurement range 100~ 300cst, equipped with 5mm flow hole and bracket, using copper Cup body, in line with ISO2431 standard, suitable for Benchtop viscosity testing.

$ 196.00

Using 4mm flow hole diaMeter, the measurement viscosity range of 34~ 135cSt, the outflow time is within 100 seconds, suitable for Newton type liquid testing, the structure is sturdy and durable.

$ 170.00

Made of stainless steel, with a flow hole diaMeter of 6mm and a viscosity range of 134-685mm ²/s, it is suitable for standard viscosity testing, and the flow time is controlled between 30 and 100 seconds.

$ 143.00

Measurement range is 7~ 40cst, flow hole diaMeter is 3mm, using copper Cup body, in line with ISO2431 standard, suitable for viscosity measurement and equipped with bracket.

$ 196.00

Articles

Application of Small Push-pull Force Gauge in Rapid Inspection of Adhesive Peel Strength for Mobile Phone Screens
This article introduces how to quickly test the peel strength of adhesive on phone screens using a small push-pull gauge.
How to choose a turbidimeter - starting with the measurement principle.
This article introduces how to select a turbidimeter, starting from the measurement principles. The main principles include the scattered light method, transmitted light method, and scattering-transmission ratio method, each suitable for samples with different concentrations.
Improving Efficiency with Vortex Mixers in Biological Sample Pre-treatment
This article primarily discusses how vortex mixers enhance the efficiency of biological sample pretreatment. By generating a vortex motion through an electric motor, they enable rapid and uniform mixing of liquids, saving time and delivering better results compared to traditional manual methods.
Handheld viscosity cups are used for rapid assessment of paint viscosity at construction sites.
A handheld viscosity cup is a portable tool used to quickly assess the viscosity of coatings at construction sites. It operates based on the flow-out time method, calculating viscosity by measuring the time it takes for the coating to flow out of the cup's orifice. It is suitable for Newtonian or approximately Newtonian fluids.
Application of Automatic Coating Machines in the Preparation of Ceramic Coatings for Lithium-Ion Battery Separators
This article discusses the application of automatic film coating machines in the preparation of ceramic coatings for lithium battery separators. Traditional manual coating methods often result in uneven coatings, which can adversely affect battery performance.
Automatic coating machines are used for the uniform application of conductive silver paste onto ITO glass.
This article explores the technique of uniformly coating conductive silver paste on ITO glass using an automatic coating machine. By controlling parameters such as coating speed and pressure, the automatic coating machine replaces traditional manual methods, thereby enhancing the consistency and repeatability of the coating process.
Application of Automatic Film Coating Machines in the Preparation of Uniform Coatings in Laboratories
This article introduces the application of automatic film applicators in preparing uniform coatings in laboratories. Traditional manual coating methods are influenced by the operator's experience, making it difficult to ensure coating consistency.
Key Points for Controlling Coating Longitudinal Uniformity with Manual Rod Coater Constant Speed Dragging Techniques
This article discusses how to control the longitudinal uniformity of the coating by dragging at a constant speed when using a manual wire rod coater. A constant-speed drag is crucial, as it directly determines the consistency of the wet film thickness.
Film applicator standardized preparation of test samples.
The film applicator is a crucial tool in fields such as coatings and inks for preparing test samples, ensuring uniform thickness and a smooth surface through standardized operations. The article introduces its scraping-based working principle and the selection between manual and automatic types.
Standards and Equipment Selection for Drop Testing in Mobile Phone Whole-Machine Reliability Testing
Drop test is an important method to test the durability of mobile phones, simulating accidental drops in daily life to examine the impact resistance of components such as the casing and screen. The test must follow international or industry standards, specifying conditions such as drop height and number of times.
Selection Comparison between Automatic and Manual Proofing Methods for Ink Proofing Machines
This article compares manual and automatic proofing methods for ink proofing machines. Manual proofing relies on the operator's experience, offering flexibility and lower initial costs, but it suffers from poor consistency, making it suitable for research and development or low-frequency usage.
The softness tester can show a data difference of up to 30% when measuring paper hand-feel samples taken from different directions.
This article mainly discusses that when testing the softness of paper, if samples are taken along different directions, such as the machine direction (longitudinal) and the cross direction (transverse), the measured data can vary significantly, sometimes by as much as 30%.
Contact Angle Meter Selection Guide: How Can Laboratory Beginners Avoid Pitfalls?
The contact angle measuring instrument is used to analyze the wettability of solid surfaces and has applications in various fields such as materials and coatings. When selecting a model as a beginner, it is necessary to first understand key parameters such as static and dynamic contact angles and surface free energy, and then choose the configuration based on the specific application scenario.
If the standard disintegrator procedure for fiber dissociation is not done correctly, the first step of paper strength testing is already compromised.
Fiber disintegration is the first step in paper strength testing. If the operation is not standardized, such as inaccurate concentration, excessive time, or incorrect rotational speed, it can lead to fiber breakage or uneven dispersion, resulting in inaccurate strength data for the prepared hand sheets.
How to Select a Pencil Hardness Tester? A Comprehensive Guide from Principles to Practical Application
When selecting a pencil hardness tester, focus on three key points: choose manual or automatic based on standards, use specialized testing pencils, and ensure the instrument can fix a 45-degree angle for uniform force application to achieve accurate and reliable results.